Decontamination is the process of removing soil and pathogenic microorganisms from objects, such as
medical devices, so they are safe to handle.
For questions 2-4, match each activity with the component of decontamination.
Using an autoclave
Disinfection
Disinfection
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 1/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Sterilization
Cleaning
Disinfection Correct!
Disinfection
Soaking
Cleaning
Disinfection
According to the Spaulding classification, what risk category are medical devices that come in contact with
mucous membranes or non-intact skin?
High risk
Question 8 00/30
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 2/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Question 8 0.0 / 3.0
According to the Spaulding classification, what risk category are medical devices that come in contact with
intact skin?
Intermediate risk
According to the Spaulding classification, what risk category are medical devices that come in contact with
with a break in the skin or mucous membrane or enter a sterile body cavity?
Low risk
Cleaning (or low-level disinfection) of medical devices is for what type of risk category?
Intermediate risk
High risk
Heat or chemical sterilization of medical devices is for what type of risk category?
Low risk
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 3/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
High-level disinfection by heat or chemicals of medical devices is for what type of risk category?
Low risk
True
False Correct!
When designing a sterile services department which one of the following statements is true?
It should not be integrated with operating theatres to enable faster decontamination. Your Answer
There should be two-way movement between dirty and clean areas to improve efficiency.
Access to the dirty and clean areas – such as the inspection, assembly and packaging
room should be through separate dedicated gowning rooms provided with hand Correct Answer
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 4/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
room – should be through separate, dedicated gowning rooms provided with hand Correct Answer
hygiene facilities.
For questions 16-20, put the steps in the correct order for decontaminating a medical device:
Step 2
Step 3
Step 5
At what step has the medical device been delivered to the receiving area outside the dirty (decontamination)
area?
Step 2
Step 3
Step 5
At what step has the medical device be sent to the clean store to await dispatch to clinical areas?
Step 1
Step 2
Step 3
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 5/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
At what step has the medical device passed through to the inspection, assembly and packaging area?
Step 1
Step 4
Step 5
At what step has the medical device been brought into the dirty area for cleaning?
Step 3
Step 4
Step 5
Before sending contaminated medical devices to the decontamination unit, you should (select all that apply):
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 6/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Protect health workers when they are transporting devices to the decontamination area
The five main elements needed for effective cleaning are (select 5):
Which of the following is required for effective cleaning? (Select all that apply):
Dry heat
Pressure cooker
Biological indicator
Physical indicator
What type of indicator is the temperature and duration of cycle time printout?
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 8/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Chemical indicator
Biological indicator
What type of indicator is placing a spore inside the load for sterilization?
Chemical indicator
Mycobacteria Correct!
Mycobacteria Correct!
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 9/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Mycobacteria
Bacterial spores
Mycobacteria
For questions 35-37, match each activity with its multimodal strategy.
Build it Correct!
Teach it
Check it
Check it
Question 37 00/30
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 10/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Question 37 0.0 / 3.0
Build it
32%
About OpenWHO
OpenWHO aims to equip all frontline responders with the knowledge they need to better contain disease outbreaks and
manage health emergencies. It also aims to foster discussions, feedback and sharing of expert knowledge on public health.