You are on page 1of 11

8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Decontamination and sterilization of medical devices OpenWHO

Post-test: Decontamination and reprocessing of


medical devices
Question 1 0.0 / 1.0

Decontamination is the process of removing soil and pathogenic microorganisms from objects, such as
medical devices, so they are safe to handle.

True Correct Answer

False Your Answer

Question 2 0.0 / 3.0

For questions 2-4, match each activity with the component of decontamination.

Using an autoclave

Sterilization Correct Answer

Cleaning Your Answer

Disinfection

Question 3 0.0 / 3.0

Scrubbing devices with a soft nylon brush (immersed in water)

Sterilization Your Answer

Cleaning Correct Answer

Disinfection

Question 4 3.0 / 3.0

Using a boiler to boil devices in 100 °C for 5-10 minutes

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 1/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Sterilization

Cleaning

Disinfection Correct!

Question 5 0.0 / 3.0

Which step needs to happen first in the decontamination process?

Cleaning Correct Answer

Disinfection

Soaking

Sterilization Your Answer

Question 6 0.0 / 3.0

Which process kills bacterial spores?

Soaking Your Answer

Cleaning

Sterilization Correct Answer

Disinfection

Question 7 0.0 / 3.0

According to the Spaulding classification, what risk category are medical devices that come in contact with
mucous membranes or non-intact skin?

Low risk Your Answer

Intermediate risk Correct Answer

High risk

Question 8 00/30
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 2/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Question 8 0.0 / 3.0

According to the Spaulding classification, what risk category are medical devices that come in contact with
intact skin?

Low risk Correct Answer

High risk Your Answer

Intermediate risk

Question 9 0.0 / 3.0

According to the Spaulding classification, what risk category are medical devices that come in contact with
with a break in the skin or mucous membrane or enter a sterile body cavity?

Low risk

Intermediate risk Your Answer

High risk Correct Answer

Question 10 3.0 / 3.0

Cleaning (or low-level disinfection) of medical devices is for what type of risk category?

Low risk Correct!

Intermediate risk

High risk

Question 11 0.0 / 3.0

Heat or chemical sterilization of medical devices is for what type of risk category?

High risk Correct Answer

Intermediate risk Your Answer

Low risk

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 3/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Question 12 0.0 / 3.0

High-level disinfection by heat or chemicals of medical devices is for what type of risk category?

Low risk

Intermediate risk Correct Answer

High risk Your Answer

Question 13 3.0 / 3.0

A good decontamination unit will have (select all that apply):

Sterilization area Correct!

Restricted access Correct!

A changing area for staff Correct!

Dirty area Correct!

Clean area Correct!

Question 14 1.0 / 1.0

It is acceptable to use a fan with an open window to create airflow.

True

False Correct!

Question 15 0.0 / 3.0

When designing a sterile services department which one of the following statements is true?

A humidity level over 85% should be maintained.

It should not be integrated with operating theatres to enable faster decontamination. Your Answer

There should be two-way movement between dirty and clean areas to improve efficiency.

Access to the dirty and clean areas – such as the inspection, assembly and packaging
room should be through separate dedicated gowning rooms provided with hand Correct Answer
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 4/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
room – should be through separate, dedicated gowning rooms provided with hand Correct Answer
hygiene facilities.

Question 16 0.0 / 3.0

For questions 16-20, put the steps in the correct order for decontaminating a medical device:

At what step has the medical device completed sterilization?

Step 1 Your Answer

Step 2

Step 3

Step 4 Correct Answer

Step 5

Question 17 0.0 / 3.0

At what step has the medical device been delivered to the receiving area outside the dirty (decontamination)
area?

Step 1 Correct Answer

Step 2

Step 3

Step 4 Your Answer

Step 5

Question 18 0.0 / 3.0

At what step has the medical device be sent to the clean store to await dispatch to clinical areas?

Step 1

Step 2

Step 3

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 5/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Step 4 Your Answer

Step 5 Correct Answer

Question 19 0.0 / 3.0

At what step has the medical device passed through to the inspection, assembly and packaging area?

Step 1

Step 2 Your Answer

Step 3 Correct Answer

Step 4

Step 5

Question 20 0.0 / 3.0

At what step has the medical device been brought into the dirty area for cleaning?

Step 1 Your Answer

Step 2 Correct Answer

Step 3

Step 4

Step 5

Question 21 2.0 / 3.0

Before sending contaminated medical devices to the decontamination unit, you should (select all that apply):

Soak the devices in water Your Answer

Properly dispose of linen and disposable items Correct!

Spray the devices with enzymatic spray (if available) Correct!

Wear appropriate personal protective equipment Correct!

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 6/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Question 22 3.0 / 3.0

Soaking instruments in 0.5% chlorine solution (or other disinfectant) can

Protect health workers when they are transporting devices to the decontamination area

Reduce the need for sterilization

Protect medical devices because it is not inactivated by organic matter

Damage or corrode medical devices Correct!

Question 23 2.4 / 3.0

The five main elements needed for effective cleaning are (select 5):

Solvent water (preferably soft) Correct!

Antiseptic agent Your Answer

Adequate contact time Correct!

Appropriate temperature (not too hot or too cold) Correct!

Mechanical action Correct!

Chemical action Correct!

Question 24 0.0 / 3.0

Which of the following is required for effective cleaning? (Select all that apply):

The use of mechanical action using soft nylon brushes Correct!

Water that is soft Correct!

Scrubbing under a running tap Your Answer

A high water temperature (greater that 60 °C) Your Answer

Question 25 0.0 / 3.0

During inspection, you should:

Make sure that devices are correctly reassembled


https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 7/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Make sure that devices are correctly reassembled

Wrap devices to allow penetration of the sterilizing agent Your Answer

Ensure that devices are visibly clean Correct Answer

Question 26 2.0 / 3.0

The purpose of packaging medical devices is to (select all that apply):

To protect medical devices from sterilants Your Answer

Allow penetration of the sterilization agent Correct!

Maintain sterility of the devices during the sterilization process Correct!

Allow devices to be removed from packaging aseptically Correct!

Question 27 0.0 / 3.0

Which is the preferred method for sterilization?

Steam sterilizer/autoclave Correct Answer

Bleach Your Answer

Dry heat

Pressure cooker

Question 28 3.0 / 3.0

What type of indicator is colour-changing tape?

Chemical indicator Correct!

Biological indicator

Physical indicator

Question 29 3.0 / 3.0

What type of indicator is the temperature and duration of cycle time printout?

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 8/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Chemical indicator

Physical indicator Correct!

Biological indicator

Question 30 0.0 / 3.0

What type of indicator is placing a spore inside the load for sterilization?

Chemical indicator

Physical indicator Your Answer

Biological indicator Correct Answer

Question 31 2.0 / 3.0

High-level disinfection can kill _____? (Select all that apply)

Mycobacteria Correct!

Vegetative bacteria and medium-sized viruses Correct!

Bacterial spores Your Answer

Small viruses and fungi Correct!

Question 32 3.0 / 3.0

Sterilization can kill _____? (Select all that apply)

Small viruses and fungi Correct!

Bacterial spores Correct!

Vegetative bacteria and medium-sized viruses Correct!

Mycobacteria Correct!

Question 33 0.0 / 3.0

Low-level disinfection can kill _____?

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 9/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |

Bacterial spores Your Answer

Mycobacteria

Vegetative bacteria and medium-sized viruses Correct Answer

Small viruses and fungi

Question 34 1.5 / 3.0

Intermediate-level disinfection can kill _____? (Select all that apply)

Vegetative bacteria and medium-sized viruses Correct Answer

Bacterial spores

Mycobacteria

Small viruses and fungi Correct!

Question 35 3.0 / 3.0

For questions 35-37, match each activity with its multimodal strategy.

Ensuring that there is soft water in the decontamination unit

Build it Correct!

Teach it

Check it

Question 36 0.0 / 3.0

Providing technical training on reprocessing equipment

Check it

Build it Your Answer

Teach it Correct Answer

Question 37 00/30
https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 10/11
8/16/2021 Post-test: Decontamination and reprocessing of medical devices |
Question 37 0.0 / 3.0

Validating steam sterilization methods

Build it

Check it Correct Answer

Teach it Your Answer

32%

Total: 34.9 of 107.0 points achieved

This quiz can be repeated indefinitely!

About OpenWHO
OpenWHO aims to equip all frontline responders with the knowledge they need to better contain disease outbreaks and
manage health emergencies. It also aims to foster discussions, feedback and sharing of expert knowledge on public health.

© 2016 - 2021 World Health Organization – Terms of Use Powered by HPI / openHPI (r6923)

https://openwho.org/courses/IPC-DECON-EN/items/5U80vNIt7CLNksuBiZvV5E/quiz_submission/2zqbAZyr7VZUOLFHFEeO1b?highest_score=true 11/11

You might also like