1.

FAN CAPACITY AND STATIC PRESSURE

A. Exis ng fan capacity :

KW1 ≔ 7.5 E ≔ 0.8 P1 ≔ 2800 KW : Power


Q : Capacity m3/s
E : Fan Efficiency
KW1 ⋅ 1000 ⋅ E P : Sta c Pressure Pa
Q1 ≔ ――――― ⋅ 3600
P1

Q1 = 7714.286 m3/h ~ 8000 m3/h

B. Power for Bagfilter Fan

8000
Q2 ≔ ――= 2.222 P2 ≔ 2800 + 1200 = 4000 E ≔ 0.8
3600

Q2 ⋅ P2
KW2 ≔ ―――
1000 ⋅ E

KW2 = 11.111 KW ~ 15 KW

2. AIR TO CLOTH RATIO FOR BAGFILTER


(Loffler et.al, Dust Collec on With Bagfilters and Envelope Filters, Friedr Vieweg &Sohn
Braunschweig/Wiesbaden)

A = air to cloth ra o base values E = gas temp factor


An = cleaning system factor F = bulk density factor
B = aplica on factor G = air to cloth ra o base factor
C = dust fineness factor H = tropical factor
D = flue gas dust load factor
A ≔ 2.2 Dust : Aluminium Oxide

An ≔ 1.5 Cleaning Pulse Jet

B ≔ 0.9 Furnace

C ≔ 0.9 5 ­ 10 um

D ≔ 0.9 120 g/m3

E ≔ 0.85 70 deg C

F≔1 1.28 g/cm3

G ≔ 0.9 base factor 2.2

H ≔ 0.8 tropical environment

X ≔ A ⋅ An ⋅ B ⋅ C ⋅ D ⋅ E ⋅ F ⋅ G ⋅ H ⋅ 60

X = 88.337 m3/m2.h ~ 85 m3/m2.h