MCC 


omponents RL101
21201 Itasca Street Chatsworth
 THRU
  !"#
$
%    !"# RL107

Features
• Low Current Leakage 1 Amp Rectifier
• Metalurgically Bonded Construction
• Low Cost 50 - 1000 Volts

Maximum Ratings
• Operating Temperature: -55°C to +150°C A-405
• Storage Temperature: -55°C to +150°C
• Maximum Thermal Resistance; 50 °C/W Junction To Lead

MCC Device Maximum Maximum Maximum


Catalog Marking Recurrent RMS DC
Number Peak Voltage Blocking D
Reverse Voltage
Voltage
RL101 --- 50V 35V 50V
RL102 --- 100V 70V 100V
A
RL103 --- 200V 140V 200V Cathode
Mark
RL104 --- 400V 280V 400V
RL105 --- 600V 420V 600V B

RL106 --- 800V 560V 800V


D
RL107 --- 1000V 700V 1000V

C
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward IF(AV) 1.0A TA = 75°C
Current
Peak Forward Surge IFSM 30A 8.3ms, half sine
Current
DIMENSIONS
Maximum
INCHES MM
Instantaneous VF 1.1V IFM = 1.0A; DIM MIN MAX MIN MAX NOTE
Forward Voltage TJ = 25°C* A .166 .205 4.10 5.20
B .080 .107 2.00 2.70
Maximum DC C --- .024 --- .60
Reverse Current At IR 5.0µA TJ = 25°C D 1.000 --- 25.40 ---

Rated DC Blocking 50µA TJ = 125°C


Voltage
Typical Junction CJ 15pF Measured at
Capacitance 1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 2%

www.mccsemi.com
RL101 thru RL107
Figure 1
MCC
Typical Forward Characteristics
20
Figure 2
10 Forward Derating Curve
6 1.2

4
1.0
2
.8
Amps 1

.6
.6
Amps
.4
.4
.2
25°C
.1 .2
Single Phase, Half Wave
.06 60Hz Resistive or Inductive Load
0
.04 0 50 75 100 125 150 175

°C
.02
Average Forward Rectified Current - Amperesversus
.01 Ambient Temperature - °C
.4 .6 .8 1.0 1.2 1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts

Figure 3
Junction Capacitance

100
60
40

20
pF TJ=25°C
10

6
4

1
.1 .2 .4 1 2 4 10 20 40 100 200 400 1000
Volts

Junction Capacitance - pFversus


Reverse Voltage - Volts

www.mccsemi.com
RL101 thru RL107
Figure 4
MCC
Typical Reverse Characteristics
Figure 5
100 Peak Forward Surge Current
60 60
40
50

20 40

10 30
6
Amps
20
4 T =100°C
A

10
2 5
0
µAmps 1 1 2 4 6 8 10 20 40 60 80 100

.6 Cycles
.4 Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.2

.1 TA=25°C

.06

.04

.02

.01
20 40 60 80 100 120 140

Volts

Instantaneous Reverse Leakage Current - MicroAmperesversus


Percent Of Rated Peak Reverse Voltage - Volts

www.mccsemi.com