You are on page 1of 12

Gable/Rake Drip x LF Gable/Rake Drip x LF

2.00 ft
L = 10.52 ft

2.00 ft
L = 10.61 ft
Slope = 8/12 Pitch

Eave Drip x LF
Slope = 8/12 Pitch

Eave Drip x LF
Gable/Rake Drip x LF
Gable/Rake Drip x LF
L = 12.08 ft
L = 9.42 ft
Slope = 5/12 Pitch
Slope = 5/12 Pitch

10.92 ft
Eave Drip x LF
Gable/Rake Drip x LF
19.42 ft

L = 9.42 ft
Eave Drip x LF

Slope = 5/12 Pitch

9.08 ft
Eave Drip x LF

Eave Drip x LF
4.71 ft
Gable/Rake Drip x LF
L = 5.78 ft
Slope = 5/12 Pitch
L = 22.24 ft

L = 22.03 ft
Slope = 8/12 Pitch

Slope = 8/12 Pitch


Gable/Rake Drip x LF

Gable/Rake Drip x LF

6.40 ft 10.48 ft
Eave Drip x LF Eave Drip x LF

Gable/Rake Drip x LF Gable/Rake Drip x LF


L = 10.34 ft L = 10.34 ft
Slope = 8/12 Pitch Slope = 8/12 Pitch
8.33 ft
Eave Drip x LF

Gable/Rake Drip x LF
L = 8.26 ft
Slope = 5/12 Pitch
15.96 ft
Eave Drip x LF

8.92 ft
33.51 ft

Eave Drip x LF
Eave Drip x LF

27.00 ft

24.60 ft
Eave Drip x LF
Eave Drip x LF

12.99 ft
Eave Drip x LF Eave Drip x LF
7.52 ft
22.50 ft
Eave Drip x LF

Gable/Rake Drip x LF
L = 0.88 ft
Slope = 4/12 Pitch

Eave Drip x LF
1.00 ft
L = 20.03 ft
Slope = 8/12 Pitch
L = 23.64 ft

Gable/Rake Drip x LF
Slope = 8/12 Pitch
Gable/Rake Drip x LF

L = 13.62 ft
Slope = 8/12 Pitch
Gable/Rake Drip x LF

Eave Drip x LF
1.00 ft Eave Drip x LF
5.92 ft
11.80 ft
3.37 ft

Gable/Rake Drip x LF Eave Drip x LF


Eave Drip x LF

Gable/Rake Drip x LF L = 12.55 ft


L = 4.82 ft Slope = 5/12 Pitch
Slope = 5/12 Pitch
8.01 ft
Eave Drip x LF

Gable/Rake Drip x LF
17.75 ft

L = 12.55 ft
Slope = 5/12 Pitch
Eave Drip x LF

13.50 ft
4.91 ft

Gable/Rake Drip x LF
L = 12.55 ft
Eave Drip x LF
side walls

Eave Drip x LF

Slope = 5/12 Pitch

Gable/Rake Drip x LF
L = 4.82 ft Eave Drip x LF
Slope = 5/12 Pitch 28.75 ft
7.94 ft
Roof and End Wall

Eave Drip x LF

Gable/Rake Drip x LF
L = 7.91 ft

9.00 ft

L = 12.55 ft
All Roof 30 Architectural

Slope = 5/12 Pitch


Slope = 4/12 Pitch
30# felt as underlayment

Eave Drip x LF
Eave Drip x LF
Gable/Rake Drip x LF

13.49 ft
3.94 ft

Gable/Rake Drip x LF
L = 30.05 ft
Curb Flashing at all Chimney

Eave Drip x LF

Slope = 8/12 Pitch


End Wall Flashing at Intersections of
Valleys and all areas below 4:12 Pitch
Ice and Water at Perimeter / Edges and

Step Flashing at intersections of Roof and


All Roof 30 Architectural

30# felt as underlayment

Ice and Water at Perimeter / Edges and


Valleys and all areas below 4:12 Pitch

Curb Flashing at all Chimney

Slo

Va 8'- 2 P
L = = 5/1
lle 3/4 itc
p e

yx "
Step Flashing at intersections of Roof and

LF
Transistions x LF
22.27 ft
Gambrel Transition Cap x LF side walls

h
14'-1 1/4"
Ridge Cap x LF Sl L Val

Ridge Cap x LF
op = ley

= 7.8 LF

h
e 3'- x

tc
25'-6 1/2"

12 ft
Pi
pe = p x
End Wall Flashing at Intersections of

4/ 5
= 10 L
8/ 1 F

i
19'-4"

H
12 /4
Pi "

L
Roof and End Wall

ch
F
tc Ridge Cap x LF

h
/12 "
8/ 1 F

Slo = 1 y x L

Pit
h

= 4 1/2

2 Pitc
o
= '-3 L

Pi "
h
12'-3"

Sl

F
12 /4
tc

Slo
e 10 x

yxL
'-2"
Va 1'-5 2 Pitc
op = ley

pe '-5
L = = 4/1

lle
pe

lley 1/4
Sl L Val

= 1/1
3
Va

L=1
Valle
Transistions x LF

xL "

4/ 1 F
= '-7 L

Pi "
h
10.92 ft

12 /2

Slope
F

tc
e 10 x

Ridge Cap x LF
op = ley
Sl L Val

9'-5 1/2"
h

ch
pe 15'-3 LF
/ 12 "
= 4 3/4

= .3 F
Pit

h
12 ft
e 19 x L

tc
x

4/ 8
Pi
L = lley

op = p
Sl L Hi
Va
Slo
Ridge Cap x LF

Va = 8 8/1
Sl
11'-3"

L e=
lle '-3 2
op

y 3/ Pit
x 4" ch
LF
Ridge Cap x LF
25'-3/4"

LF Hip Va

Ridge Cap x LF
le y x /2" lley

H 16 /12
l x

Sl
Va 4'-4 1 itch L = 3. LF

L e=
L

ip .7 P
Slo x

op
Slo =
pe 25' LF

= 4
1 P pe = 85 f

x 7 it
L = = 3/12

58'-7"
-

LF ft ch
3/12 t = 2 6"
/12
pe Pitc
Slo h Pit
ch

Transistions x LF

Transistions x LF
11.63 ft

Gambrel Transition Cap x LF


22.25 ft

5'-4 1/2"
F
yxL
Valle 3'-6"
L = 2 12 Pitch
o p e = 2/
S l

h
Pitc
3/12 4"
F
Ridge Cap x LF

L = lley x L
pe = 4'-4 1/
31'-9"
LF ft ch
x 14 Pit

1
Va
ip .
H 24 /12 Transistions x LF Transistions x LF

Va = 1 8/1
= 3

Sl
8.00 ft 8.00 ft

Slo

L e=
L e=

lle 2'- 2
op

y 1/ Pit
op

x 2" ch
Sl

LF
Ridge Cap x LF
1'-0"
Step Flashing x LF
L = 5'-5"
Slope = 5/12 Pitch

Step Flashing x LF
L = 2'-2"
Slope = 5/12 Pitch

Step Flashing x LF
L = 5'-4 1/2"
Slope = 5/12 Pitch

Step Flashing x LF
L = 2'-2"
Slope = 5/12 Pitch

Step Flashing x LF Step Flashing x LF


L = 7'-1/2" L = 7'-1/4"
Slope = 4/12 Pitch Slope = 4/12 Pitch

2'-0"
2'-0"

Curb Flashing x LF
L = 9'-4 1/4"
Slope = 8/12 Pitch
Curb Flashing x LF
Curb Flashing x LF
L = 9'-1 1/4"
Slope = 4/12 Pitch
Step Flashing x LF

9'-6"
End Wall Flashing x LF

Step Flashing x LF
L = 8'-1/2"
Slope = 3/12 Pitch
17'-9 3/4"

L = 7'-11 1/4"
End Wall Flashing x LF

Slope = 3/12 Pitch


Step Flashing x LF

Step Flashing x LF
L = 2'-3/4"
Slope = 3/12 Pitch Step Flashing x LF
L = 10'-8 1/2"
Slope = 8/12 Pitch Step Flashing x LF
L = 12'-7 3/4"
Step Flashing x LF
Slope = 1/12 Pitch
L = 1'-1/2"
Slope = 4/12 Pitch

Step Flashing x LF
L = 1'-9 1/4"
Slope = 8/12 Pitch

Step Flashing x LF
L = 6'-3 1/4"
Slope = 8/12 Pitch

Step Flashing x LF
L = 10'-9 3/4"
Slope = 5/12 Pitch

Step Flashing x LF
L = 10'-9 3/4"
Slope = 5/12 Pitch
13'-7 1/2"
side walls

Step Flashing x LF
End Wall Flashing x LF

L = 10'-9 3/4"
Slope = 5/12 Pitch
End Wall Flashing x LF
13'-6 1/4"
Roof and End Wall

Step Flashing x LF
L = 7'-8 3/4"

L = 10'-9 3/4"
All Roof 30 Architectural

Slope = 4/12 Pitch


Step Flashing x LF
30# felt as underlayment

Slope = 5/12 Pitch


Curb Flashing at all Chimney

End Wall Flashing at Intersections of


Valleys and all areas below 4:12 Pitch
Ice and Water at Perimeter / Edges and

Step Flashing at intersections of Roof and


All Roof 30 Architectural

30# felt as underlayment


Ice & Water Shield x LF

Ice & Water Shield x LF


19'-5"

Ice and Water at Perimeter / Edges and

5'-4"
Ice & Water Shield x LF

Ice & Water Shield x LF Valleys and all areas below 4:12 Pitch
Slope = 5/12 Pitch

2'-0" Ice & Water Shield x LF


L = 22'-2 3/4"
L = 12'-1"

Ice
Slope = 8/12 Pitch

&
Curb Flashing at all Chimney

W = 8' /12 P
Slo

ate -3

Ice & Water Shield x LF


L
pe

Ice & Water Shield x LF


r S /4" itch
=5
Ic

hie
e
& Ice & Water Shield x LF
Step Flashing at intersections of Roof and

10'-5 3/4"
ld
W Ice & Water Shield x LF
Sl L at 33'-6"

xL
op = er

1'-11"
L = 23'-7 3/4"
Ice & Water Shield x LF

Ice & Water Shield x LF e 3'- Sh side walls

F
= 10 ie Slope = 8/12 Pitch
Slope = 8/12 Pitch

22'-3 1/4" 8/ 1 ld
L = 21'-1 1/2"

12 /4 x
Pi " LF Ice & Water Shield x LF
tc

Ice & Water Shield x LF


h 14'-0"
Ice & Water Shield x LF
L = 1'-5 1/2"
End Wall Flashing at Intersections of

LF
Slope = 4/12 Pitch
Roof and End Wall

12 /4 x

LF
8/ 1 ld

11'-10"
= '-3 ie

Pi "
h
e 10 Sh

L = 1 r Shield x
tc
Ice & Water Shield x LF

h
Ice & Water Shield x SF

2 Pitc
op = er

"
10'-11"

Slope 5'-2 3/4


Sl L a t
A = 235.57 sf

Ice & Water Shield x LF

LF
Slope = 1/12 Pitch
&
Ice & Water Shield x LF

Ice & Water Shield x LF

= 1/1

Ice & Water Shield x LF


Ice & Water Shield x LF

12 /2 x
Ice & Water Shield x LF
Ic

Wate
4/ 1 ld
Slope = 5/12 Pitch

Slope = 5/12 Pitch

= '-7 ie
L = 1'-5 1/4"

Pi "
h
e 0 Sh

tc
Ice & Water Shield x LF

6'-4 3/4"
Ice & Water Shield x LF Slope = 4/12 Pitch

2'-3 1/2" op = 1 er

22'-5 3/4"
L = 9'-5"

L = 9'-5"

Ice &
17'-9"
4'-8 1/2"

Sl L at
2'-0"

W
Ice & Water Shield x LF

LF
&
21'-0"

e
Ic

x
Ice & Water Shield x LF Ice & Water Shield x LF

Ice & Water Shield


Ice & Water Shield x LF
L = 22'-1/2" 7'-6"

F
27'-0"

= 4 -3 3/4 ld x L
Slope = 8/12 Pitch
Ice & Water Shield x LF

Ice & Water Shield x LF

ch
/ 12 "
e
10'-11"

Slope = 8/12 Pitch

Pit
Slo = 15 r Shi
L = 10'-4 1/4"

L ate
'
&W

pe
Ice
Ice & Water Shield x LF
L = 7'-10 3/4"

Ic
Slope = 4/12 Pitch

Ice & Water Shield x LF


&
W 8 8/
Sl

at '-3 12
L
Ice & Water Shield x LF

er 3 P
op
=
Slope = 8/12 Pitch

Sh /4 itc
=

28'-9"
ie " h
L = 9'-4 1/4"

Ice & Water Shield x LF


ld
x
LF
LF Ice
dx

13'-5 3/4"
i el &W
Sh 2" ate
ter
& W 4'-4 1/ itch
a Slo L = r Shi
Ice L = 1 3/12 P pe 25' eld
= 2 -6" xL
pe = /12 F
Slo Pit

Ice & Water Shield x LF


Ice & Water Shield x LF ch
Slope = 8/12 Pitch

11'-4 1/4"
Ice & Water Shield x SF
L = 10'-4 1/4"

A = 315.04 sf
Slope = 2/12 Pitch Ice & Water Shield x LF

Ice & Water Shield x LF


9'-0"

5'-4 1/2"
Ice & Water Shield x LF

Ice & Water Shield x LF


Slope = 5/12 Pitch Ice & Water Shield x SF
16'-0" A = 326.85 sf
L = 8'-3 3/4"

Slope = 3/12 Pitch

LF
r S h ield x
Wate "
Ice & L = 23'-6 itch

Ice & Water Shield x LF


pe = 4'-4 1/ ld x LF
P
2/12

Slope = 8/12 Pitch


Ice & Water Shield x LF e =
Slop

L = 30'-1/2"
Pitc
8'-11"

3/12 4"
Ice & Water Shield x LF

e
Ice & Water Shield x LF

L = ter Shi
8'-0" 8'-0"

Ic
1

e
a
&W

& L =
W = 1 8/
Ice & Water Shield x SF

Sl

at 2 12
Slo

er '-1 P
op
Ice
A = 89.56 sf

Sh /2 itc

Ice & Water Shield x LF

Ice & Water Shield x LF

Ice & Water Shield x LF

Ice & Water Shield x LF


Slope = 3/12 Pitch

ie "
ld

Slope = 5/12 Pitch

Slope = 5/12 Pitch

Slope = 5/12 Pitch

Slope = 5/12 Pitch


x

L = 12'-6 3/4"

L = 12'-6 3/4"

L = 12'-6 3/4"

L = 12'-6 3/4"
LF
h
Ice & Water Shield x LF
Ice & Water Shield x LF
7'-6 1/4"

5'-11"

Ice & Water Shield x LF

Ice & Water Shield x LF


Ice & Water Shield x LF Ice & Water Shield x LF Ice & Water Shield x LF

Slope = 5/12 Pitch

Slope = 5/12 Pitch


L = 4'-10 1/2"

L = 4'-10 1/2"
2'-10" Ice & Water Shield x LF 3'-10 1/4" Ice & Water Shield x LF 3'-4"
8'-1/2" 8'-3/4"
Ice & Water Shield x LF
Ice & Water Shield x LF L = 13'-7 1/2"
L = 20'-1/4" Slope = 8/12 Pitch Ice & Water Shield x LF
Slope = 8/12 Pitch 13'-6"
All Roof 30 Architectural

30# felt as underlayment

Ice and Water at Perimeter / Edges and


Valleys and all areas below 4:12 Pitch
30 Year Architectural Shingles
A = 240.61 sf
Slope = 5/12 Pitch
Curb Flashing at all Chimney

Step Flashing at intersections of Roof and


side walls
30 Year Architectural Shingles
A = 142.89 sf
Slope = 4/12 Pitch
30 Year Architectural Shingles End Wall Flashing at Intersections of
30 Year Architectural Shingles A = 376.08 sf
A = 244.04 sf Slope = 8/12 Pitch Roof and End Wall
Slope = 8/12 Pitch

30 Year Architectural Shingles Low Slope Pitch Roofing


A = 38.96 sf A = 236.82 sf
30 Year Architectural Shingles Slope = 4/12 Pitch Slope = 1/12 Pitch
30 Year Architectural Shingles A = 119.8 sf
A = 102.89 sf Slope = 4/12 Pitch
Slope = 5/12 Pitch

30 Year Architectural Shingles


A = 198.7 sf
Slope = 4/12 Pitch

30 Year Architectural Shingles 30 Year Architectural Shingles


A = 642.94 sf A = 185.67 sf
Slope = 8/12 Pitch Slope = 4/12 Pitch

30 Year Architectural Shingles


30 Year Architectural Shingles A = 66.7 sf 30 Year Architectural Shingles
A = 995.14 sf Slope = 4/12 Pitch A = 107 sf
Slope = 8/12 Pitch Slope = 4/12 Pitch

30 Year Architectural Shingles


A = 315.04 sf
30 Year Architectural Shingles Slope = 2/12 Pitch
A = 78.48 sf 30 Year Architectural Shingles 30 Year Architectural Shingles
Slope = 5/12 Pitch A = 437.78 sf A = 201.62 sf
Slope = 3/12 Pitch Slope = 8/12 Pitch

30 Year Architectural Shingles


30 Year Architectural Shingles 30 sfYear Architectural Shingles
A = 235.8
A = 100.38 sf Slope = 8/12 Pitch A = 100.38 sf
Slope = 5/12 Pitch Slope = 5/12 Pitch

30 Year Architectural Shingles Unspecified Roofing


A = 15.44 sf A = 66.05 sf
Slope = 8/12 Pitch Slope = 5/12 Pitch
All Roof 30 Architectural

30# felt as underlayment

Ice and Water at Perimeter / Edges and


Valleys and all areas below 4:12 Pitch

Curb Flashing at all Chimney

Step Flashing at intersections of Roof and


side walls

End Wall Flashing at Intersections of


Roof and End Wall

Roof Area = 5249.24 sf

Ice & water shield LF @


Perimeter = 625' 7 1/4'' LF Roof Felt x SF
2,717.89 sf

625' 10 1/2'' x 2'6'' = 1564.7 sf

Ice & water shield SF = 967.02 sf

Roof felt SF = Total roof area -


(I&W @ Perimeter x 2.5 -I&W SF)

= 5249.24 - (1564.7 - 967.02)


= 5213.59 - 2521.72
= 2717.52 SF
All Roof 30 Architectural

30# felt as underlayment

Ice and Water at Perimeter / Edges and


Valleys and all areas below 4:12 Pitch

Curb Flashing at all Chimney

Step Flashing at intersections of Roof and


side walls

End Wall Flashing at Intersections of


Roof and End Wall