DIMENSIONAMIENTO Y DISEÑO ZAPATA CONECTADA

0.50 0.70

0.50 C1 C2

LP 6.20 m

P1D = 70.00 T P2D = 120.00 T σt = 3.50 kg/cm2 fy = 4,200.00 kg/cm2


P1L = 26.00 T P2L = 45.00 T γm = 2.00 T/m3 f´c = 210.00 kg/cm2
S/c = 0.40 T/m2 hf = 1.50 m

P1 = 96.00 T P2 = 165.00 T
P1u = 142.20 T P2u = 244.50 T
DIMENSIONAMIENTO

DIMENSIONAMIENTO Y DISEÑO ZAPATA CONECTADA

0.50 0.70
0.50 0.70

T C1 C2
0.50 C1 0.50 VC C2 L

LP 6.20 mm
6.20
S L
ZAPATA EXTERIOR
P1D =
Estimar: 70.00 T P2D = 120.00 T σt = 3.50 kg/cm2 fy = 4,200.00 kg/cm2
P1L = 226.00 T P2L = 45.00 T γm = 2.00 T/m3 f´c = 210.00 kg/cm2
Az = 3.65 m
S/c = 0.40 T/m2 hf = 1.50 m
σn = 31.6 t/m2
Dimensioanamiento en planta:

2 S2 = Az S = 1.35 m Usar: S = 1.35 m


DIMENSIONAMIENTO

0.50 0.70

T C1 0.50 VC C2 L

6.20 m
S L

VIGA DE CONEXIÓN

h = 6.20/7 b= 96
31* 6.2
h = 0.89 m
b = 0.50 m b > h/2

USAR: 0.50 x 0.90


DIMENSIONAMIENTO

Wv = 0.50*0.9*2.4 Wv = b x h x 2.4 96.00 P1

0.50 Wv 0.70
Wv==1.08
1.08T/m
Wv = 1.08 T/m
2
T C1 0.50 VC C2 L

ΣM2 = 0
RN = 106.96 T 6.20 m
S L
S = 1.35

Az = 3.38 m2
0.675 RN 5.775

T = 2.51 m Az = T x S 6.45

σn = 31.6 t/m2
USAR : 2.55 x 1.35
DISEÑO DE LA VIGA DE LA CONEXIÓN

142.20 Pu1
Pu1 = 142.20 t
Wvu = 1.512
Wvu = 1.512 t-m 2

WNu

S = 1.35
ΣM2 = 0

RNu = 158.11 t RNu 5.775

WNu = 117.12 t/m 6.20


DISEÑO DE LA VIGA DE LA CONEXIÓN

SECCION MOMENTO MAXIMO 142.20 Pu1

Wvu = 1.512
2
Xo = 142.20 Xo = P1u
117.12 – 1.512 WNU - Wvu
WNu 117.12
Xo = 1.23 m

Xo = 1.23 < S = 1.35 Xo

Diseño de acero d = 80.28 cm


As = 19.00 cm2 a = 8.94 cm
As = 18.11 cm2
Mu max = -51.90 t-m

usar: 4 φ 1"
ρ = 0.0051 > ρmin = 0.0024
DISEÑO DE LA VIGA DE LA CONEXIÓN

REFUERZO EN LA CARA INFERIOR

4 ϕ 1”

4 ϕ 3/4”

+ As min = 9.63 cm2


A s= 20.28 cm2

-
As= 6.76 cm2 ~ 10.14 cm2 4 ø ¾”
DISEÑO DE LA VIGA DE LA CONEXIÓN

DISEÑO POR CORTE


P V1du
V 1du = (W Nu - W vu ) (t 1 + d) - P 1u
d W2u Wvu
V1du = 8.41 t

V2u = (WNu - Wvu) S - P1u


WNu 13.38
V2u = 13.87 t

Vu = 13.87 t Vc = 30.83 t

Usar estribos de montaje: φ = 3/8" para barras hasta de 3/4"


φ = 1/2" para barras mayores de 3/4"
4 ϕ 1” S= 0.35 m de 3/8" para acero de 3/4"

S= 0.45 m de 1/2" para acero de 1"

4 ϕ 3/4”
DISEÑO DE LA ZAPATA EXTERIOR
DIMENSIONAMIENTO: hz 0.50
1.025
WNu = 55.76 T/m

Mumax = 29.29 t - m

WNu

2.55
ρ = 0.004 W = 0.0800 DISEÑO POR CORTE

d = 38.81 cm

h = 47.27 cm Vud = 28.41 t

usar: h= 60.00 cm
Vn = 37.89 t Vc = 53.44 t
d= 51.55 cm
DISEÑO POR FLEXION

Mu = 29.29 t - m

As = 16.71 cm2 a= 2.91 cm

As = 15.47 cm2 a= 2.70 cm

n= 6 s= 0.24 m

usar : φ 3/4" @ 0.24

refuerzo transversal Ast = 27.54 m2 0.0018*b*t

n= 10 s= 0.27 m

usar : φ 3/4" @ 0.27


DISEÑO DE LA ZAPATA INTERIOR

DIMENSIONAMIENTO:

P2efec = -161.01 t

Az = 5.10 m2

σn = 31.6 t/m2
L = 2.26 m
Pu2efec = 238.34 t

usar: 2.30 x 2.30

Wnu = 30.43 t-m2


DISEÑO DE LA ZAPATA INTERIOR

a= 0.62 m Lv = 0.84 m

Mu max = 10.74 t-m

ρ = 0.004 W = 0.0800
Wnu = 30.43 t-m2
d = ??????? cm

usar: h= 60.00 cm d= 51.55 cm


DISEÑO DE LA ZAPATA INTERIOR

VERIFICACION POR PUNZONAMIENTO:


Wnu = 30.43 t-m2
m= 1.72 m m = Lv + a + d/2

n= 1.14 m n=a+d

bo = 5.71 m

Vu = 101.33 t Vn = 135.11 t Vc = 451.90 t

VERIFICACION POR CORTE:

Vud = 22.40 t

Vn = 29.86 t Vc = 91.05 t
DISEÑO DE LA ZAPATA INTERIOR

DISEÑO POR FLEXION:

As = 20.84 cm2 Mu max= 36.54 t-m

As = 19.15 cm2 a= 2.13 cm

n= 10 s= 0.24

usar : φ 5/8" @ 0.24


φ 5/8" @0.24
φ 3/4" @0.24
2.55 VC 2.30

φ 5/8" @0.24

φ 3/4" @0.27 2.30

1.35

0.50 0.70
φ 1/2" @ 0.45

4 φ 1"

4 3ø φ¾”
1"