Professional Documents
Culture Documents
Birotor Plus Positive Displacement Meter: Technical Data
Birotor Plus Positive Displacement Meter: Technical Data
BiRotor Plus
Positive Displacement Meter
General Dependability
The BiRotor Plus is an extremely accurate dual cased flow There is no metal to metal contact between the rotors and
measuring device. It produces via the use of non wetted the measurement chamber. The meter is therefore ex-
pickoffs a high resolution signal which is directly propor- tremely durable. The rotors, bearings and timing gears are
tional to the rate of liquid flow through the meter. These the only moving parts. Maintenance requirements are the
signals are shaped by a simple internal pre-amplifier for lowest in the industry.
transmission to ancillary equipment.
Affordability
The BiRotor Plus Meter utilizes the exclusive BiRotor
No premium for superior performance. Brodie offers the
principle. There are no sliding, oscillating, or reciprocating
BiRotor Plus at a very competitive price.
parts.
Accuracy Flexibility
The BiRotor Plus meter is the most accurate PD meter in The BiRotor plus meter can be installed either vertically
the market. Outperforming any other meter in the industry, or horizontally. It offers direct pulse output. And it is field
this meter is capable of a linearity of +/- 0.075% with a proven in thousands of installations.
repeatability of 0.02%.
Linearity Repeatability
B27X Standard Rotors (All Sizes):
+/- 0.1% Over Standard Flow Range 0.02% std. Rotors
+/- 0.15% Over Extended Flow Range 0.04% X-Clearance
[Premium accuracy is also available]
B28X and B29X Standard Rotors
+/- 0.075% Over Standard Flow Range Viscosity Range
+/- 0.15% Over Extended Flow Range
Standard: 0.2 - 1000 cSt
96 PUL/GAL
B29X C6 standard 100 1000 143 1429 379 3785 23 227
25 PUL/L
40 PUL/GAL
B30X D6 standard 175 1748 250 2497 662 6617 39 397
11 PUL/L
40 PUL/GAL
B31X D8 standard 281 2818 402 4025 1066 10667 64 640
11 PUL/L
40 PUL/GAL
B32X D10 standard 281 2818 402 4025 1066 10667 64 640
11 PUL/L
(145) 21
(124) 18
Max Recommended
(103) 15
Pressure Drop PSI & (kPa)
Pressure Drop*
(83) 12
(62) 9
(41) 6
(0) 0
100 200 300 400 500 600 700
(379) (757) (1136) (1514) (1893) (2271) (2650)
Flow Rate GPM & (L/min)
*NOTE: This is based upon process conditions
Models B28X & B29X (C4 & C6 Series)
(145) 21
(124) 18
Max Recommended
(103) 15
Pressure Drop PSI & (kPa)
Pressure Drop*
(83) 12
(62) 9
(145) 21
St
t
t
cS
cS
c
t
cS
(124) 18 St
179
0
39
1c
7
78
2.
Max Recommended
(103) 15 Pressure Drop*
Pressure Drop PSI & (kPa)
(83) 12
(62) 9
(41) 6
(0) 0
714 1429 2143 2857 3571 4286 5000
(114) (227) (341) (454) (568) (681) (795)
Flow Rate BPH & (m3/hr) *NOTE: This is based upon process conditions
Preamplifier
Supply voltage: 9 to 30 VDC Variable voltage pulses: 0 to supply voltage less 5%
Outputs (jumper selectable): square wave 0 to 5 KHz 70 mA max
5 V powered pulse: 0 – 5 VDC, 20 mA max
Wiring Connections
Channel A Output
- Common
+9 to 30 VDC
+ Channel B Output
(For Customer Use)
TB1 1 2 3 4 5
White A B A B Red
1 2
1 2
PICKOFF PICKOFF
Red J3 J4 White
TB2 TB3
Channel A Channel B
B A
B A
J2
J1
Unit weights
Series Model Size Unit Weight
3” ANSI 150# lb 157
DN80 PN16 kg 71
B3 B 27 X
3” ANSI 300# lb 165
DN80 PN 40 kg 75
4” ANSI 150# lb 212
DN100 PN16 kg 96
4” ANSI 300# lb 233
C4 B 28 X
DN100 PN40 kg 106
lb 750
4” ANSI 600#
kg 340
6” ANSI 150# lb 244
C6 B 29 X
DN150 PN 16 kg 111
lb 968
6” ANSI 150#
kg 439
lb 1006
D8 B 30 X 6” ANSI 300#
kg 456
lb 1500
6” ANSI 600#
kg 680
lb 990
8” ANSI 150#
kg 449
D6 B 31 X
lb 1046
8” ANSI 300#
kg 474
lb 1014
10” ANSI 150#
kg 460
D10 B 32 X
lb 1088
10” ANSI 300#
kg 494