Test Kit For Lub Oils

You might also like

You are on page 1of 22
MUTE Tele De ula OLR es nt OU iis aS WE Test Kits for Lubricating Oils Instruction Manual Interpreting Results Water in Oil Test TBN Test Salt Water Determination Insolubles Loading Viscosity Test TAN Test Parker ee ENGINEERING YOUR SUCCESS. Scanned with CamScanner t Viscosity Comparison Take samples of used and new oil and allow to stand for at least 1 hour. It is very important that both samples are at the same temperature. Place the Viscosity Stick on a flat, level surface. Add 5ml of used oil to one reservoir. Add 5ml of new oil to the other reservoir. Tilt the Viscosity Stick so that it rests on the angled base and allow the oil to run down the channels. When the new oil reaches the mid point on the scale, return the Viscosity Stick to the horizontal. MA-K15685-KW Issue 1 Scanned with CamScanner Examine the point reached by the used oil: If the used oil has not reached the scale then the viscosity is higher than recommended. If the used oil has over run the scale then the viscosity is lower than recommended. New oil Used oil Used oil viscosity high. Scanned with CamScanner Salt Water Determination MA-K15686-KW Issue 1 Add 2ml of Reagent H to the test tube. Shake the oil sample and draw off 5ml using the syringe provided. Add this to the test tube, replace the cap and shake vigorously. Place the tube upright in hot water and allow to stand for 1 hour until the water settles out of the oil sample. Take one test pad from the box and replace the lid. Handle the test pads by the edges to avoid contaminating the surfaces with sweat. Puncture an area 10mm in diameter 10 to 15 times with the pin provided. Flush a pipette with Reagent H. Place the tip in the water layer in the test tube. Squeeze the bulb gently and draw off a sample of the water into the pipette. Scanned with CamScanner B Remove the pipette and wipe off any oil and return a few drops of water to the test tube. Place the next drop of water onto the prepared test pad. oo Allow the pad to stand for 5 minutes. Examine the pad: If there is no yellow colour, or only a very faint yellow patch appears, the contamination is fresh water. If a large yellow patch appears, the contamination is salt water. 6 | A positive result should always be checked by testing another pad. Scanned with CamScanner Reset Control Screen Button Battery guaranteed for 5 years Buttons to (or 5000 tests). action screen options Press Right hand button to switch cell on. Cell will auto power off after 6 minutes inactivity. Press TBN to switch between WATER/TBN mode. Select oil desired for test by pressing OIL. If oil is not found, or if you have a new oil, follow TBN Setup instructions on previous page. TBN TEST TBN TEST Name=Oil Type 1 Name=Oil Type 2 New TBN=46 New TBN=42 Name=Oil Type 1 Last TBN=27.3 Last TBN=24.9 TBN is relative WATER OIL NEXT] |WATER OIL NEXT to new oil NEW-test new oil LLY’ JY, RRS NeW. BACK NEW NEXT = Press NEXT to continue MA-K16800-KW Issue 3 Scanned with CamScanner Before starting the test: Make sure the inside of the cell is clean and dry (pay particular attention to the seal). Begin test by following on screen instructions. Name=Oil Type 1 NB: Use TBN Reagent C. The 4)Add reagent to amount of oil used changes with lowerline the new oil TBN range. 2)Add XXml oil 3)Replace lid BACK START|P Replace lid and press START to begin test. Please make sure that you use the correct amount of reagent and oil. Failure to do this could cause the cell to become over-pressured and damaged. s 4 Scanned with CamScanner a 6 | sie cell To cancel the test until graph ha hed CANCEL for seconds. CANCEL - hold 5 sec 45 31 : = Agraph will be plotted during the test time (120 seconds). —= . CANCEL - hold 5 sec Name=Oil Type 1 Yo i i id ur results will be displayed after New EN the graph has been plotted. Used TBN = 36 NEXT|P> Press NEXT to return to first screen. After finishing the test: Immediately after every test, thoroughly clean the cell paying particular attention to the O ring and sealing faces, there should be no reagent residue left in these areas. Where applicable, the agitator will also require cleaning. Use a lint-free rag or tissue and a mild solvent (e.g. Reagent A or IPA). Do not use water or water based cleaners! MA-K16800-KW Issue 3 Scanned with CamScanner Test Kits, Spares and Reagents Code FG-K1-001-KW FG-K1-003-KW FG-K1-004-KW FG-K1-007-KW FG-K1-008-KW FG-K1-010-KW. FG-K2-001-KW FG-K2-002-KW FG-K2-003-KW FG-K1-006-KW FG-K1-005-KW FG-K24743-KW FG-K3-020-KW AS-K13888-KW AS-K13889-KW AS-K13890-KW MA-K12804-KW MA-K17478-KW Issue 1 Description DIGI Water Kit DIGI Basic Kit DIGI TBN Kit al Kit DIGI Industri DIGI Field Kit DIGI Combined Kit Water in Oil Reagent Pack (50) TBN Reagent Pack (50) Insolubles Reagent Pack (50) ECON Insolubles Test (100) ECON Salt Test (30) ECON TAN Drop Test Kit (50) ECON Viscosity Test Digital Water Cell (5 year battery) Digital TBN Cell (5 year battery) Digital Water & TBN Cell (6 year battery) Fuel & Lube Oil Training CD Range 0-125, 0-10%, 0-20%. 1-10,000ppm Water/Visc/Insols/Salt 5-80 TBN Water/TBN/Visc/Insols Water/TBN/Visc/Insols/ TAN Water/TBN/Visc/Insols/ Salt qualitative qualitative 0-6 TAN go/no go 0-1%, 0-10%, 0-20%, 1-10,000ppm 5-80 TBN 5-80 TBN, 0-1%, 0-10% 0-20%, 1-10,000ppm Scanned with CamScanner Test Kits, Spares and Reagents cont. Code Description Range FG-K1-101-KW EasySHIP DIGI Water Kit 0-1%, 0-10%, 0-20% 1-10,000ppm FG-K1-102-KW EasySHIP DIGI Water kit 0-1%, 0-10%, 0-20%, 1-10,000ppm FG-K1-103-KW EasySHIP DIGI Basic Kit Water/Visc/Insols/Salt FG-K1-107-KW. EasySHIP DIGI Industrial Kit Water/TBN/Visc/Insols FG-K1-109-KW EasySHIP DIGI Industrial Oil Kit Water/TBN/Insols/Visc FG-K1-110-KW EasySHIP DIGI Combined Kit Water/TBN/Visc/Insols/ Salt FG-K2-101-KW. EasySHIP Water in Oil Reagent Pack (50) ( \ Scanned with CamScanner MA-K15687-KW Issue 4 6 Insolubles Loading Shake the oil sample bottle to mix the contents and pour a small volume into the beaker. Place a clean filter paper on a level surface. Dip the acetate rod into the oil and allow the first drop to return to the beaker. Place the second drop onto the paper and set aside for 24 hours. Compare the dried spot with the examples given on the page below. Scanned with CamScanner Insolubles % wiw approx. Light (<0-1) Medium (1-2) Heavy (>2) | > Insolubles This is indicated by the shade of the spot. A very dark spot indicates a heavy insolubles loading. If the dispersency is poor, only the centre of the spot will be dark. Poor (<1) Dispersency TBN - mg.KOH approx. Moderate (1-2) Good (>5) Dispersency This is indicated by the colour change from the centre to outside of the spot. A distinct colour change indicates reduced dispersency. (Low TBN is also an indication of reduced dispersency). Scanned with CamScanner Water in Oil Test Control Reset Screen Button Battery guaranteed for 5 years Buttons to (or 5000 tests). action screen options Press Right hand button to switch cell on. Cell will auto power off after 6 minutes inactivity. Press WATER to switch between WATER/TBN mode. Press RANGE to change the required range of the test. Four test ranges are available: WATER TEST Range 0 - 10% Range 0.02 - 1.0% AERIEST Range 200 - 10,000ppm IRange=0.02-1.0% Wseeeaeo oon Range 0 - 20% ITBN RANGE NEXT| WATER TEST |Range=200-10,000ppm} Vv lLast test=000 ‘ TEN RANGE NEXT. WATER TEST IRange=0-20% Last test=0.00% TEN RANGE NEXT Press NEXT to continue with chosen range. SELECTMETHOD | Dregs 1 to run the test with Reagent B Powder or = Reag B Powder 2 to test with EasySHIP Paste. l2= EasySHIP Paste BACK 1 2 Scanned with CamScanner When using EasySHIP Paste Before starting the test: make sure that the inside of the cell is clean and dry (pay particular attention to the seal). EasySHIP Test Reagent must be above 18°c Always start the test with the highest range selected, when in doubt about the approximate amount of water in your test oil. Overpressure can occur if an oil sample is tested with a very high water content on the low range 0.02-1% (200-10000ppm). This can cause permanent damage to the pressure sensor. Shake the bottle of Reagent A thoroughly. Begin test by following on screen instructions. NB: The amount of oil used changes with the range. Always use 20ml Reagent A (or up to the top line in the cell). > Always use gloves when handling EasySHIP Sachets. 1)Add 20m! ReagA 2)Add All Paste” 3)Add XXml Oil 4)Add Agitator 5)Replace Lid BACK START *Squeeze all of the EasySHIP Paste into the centre of the cell >. LL. Replace lid and press START to begin test. Skip next page for the remainder of the EasySHIP test method @ — yo a Scanned with CamScanner When using Reagent B Powder Before starting the test: make sure that the inside of the cell is clean and dry (pay particular attention to the seal). Always start the test with the highest range selected, when in doubt about the approximate amount of water in your test oil. Overpressure can occur if an oil sample is tested with a very high water content on the low range 0.02-1% (200-10000ppm). This can cause permanent damage to the pressure sensor. Shake the bottle of Reagent A thoroughly. Begin test by following on screen instructions. NB: The amount of oil used changes 4)Add 20m! ReagA 2)Add XXmi Oil with the range. Always use 20ml 3)Cut ReagB pack Reagent A (or up to the top line in the 4)Place in cell cell). 5)Replace lid Always use gloves and tweezers ar sranu> when handling Reagent B. BACK Replace lid and press START to begin test. Tum page for remainder of test MA-K17476-KW Issue 3 Scanned with CamScanner Shake cell vigorously until graph To cancel the test has finished press and hold CANCEL for 5 CANCEL - hold 5 sec ue 50 Agraph will be plotted during the test 1.47% time ca (180 seconds for the EasySHIP Test — and 120 seconds for the Reagent B CANCEL - hold 5 sec Test). Test complete Your results will be displayed after 1.52% the graph has been plotted. Water in Oil NEXT | > Press NEXT to repeat test. Please make sure that you use the correct amount of reagent and oil. Failure to do this could cause the cell to become over-pressured and damaged. After finishing the test: Immediately after every test, thoroughly clean the cell paying particular attention to the O ring and sealing faces, there should be no reagent residue left in these areas. Where applicable, the agitator will also require cleaning. Use a lint-free rag or tissue and a mild solvent (e.g. Reagent A or IPA). Do not use water or water based cleaners! Confidence Test: Check that the cell is working by conducting a test with no oil added and add 1 drop of water before starting the test. This should give a positive result above 0.02%. l 0 Gq Scanned with CamScanner TBN Setup TBN is determined by measuring the pressure build-up in the cell when a predetermined quantity of oil sample is added to a special reagent. The amount of sample needed is determined by the cell measurement processor and is based on the expected TBN. When using this instrument for the very first time it is necessary to calibrate it for each of the oil grades to be measured. The cell is able to hold calibration data for up to seven different oil grades. The calibration process requires a sample of new oil for each of the grades to be measured. We recommend you use the oil grade name as the "Name" during the cell setup process. The cell should be re-calibrated approximately every six months. The calibration can be checked by using new oil in the TBN test procedure, in place of used oil. The ‘test’ TBN should be close to the new oil TBN. Press Right hand touch pad to switch cell on. Cell will auto power off after 6 minutes inactivity. Press TBN to switch between WATER/TBN mode. Select the oil to be changed or edited by pressing OIL. Once oil is selected, press NEXT to continue. TBN TEST TBN TEST Name=Oil Type 1 New TBN=46, Name=Oil Type 1 Last TBN=27.3 es TBN is relative WATER OIL NEXT to new oil NEW-test new oil NEXT-test used BACK NEW NEXT v Press NEW to continue MA-K15691-KW Issue 1 Scanned with CamScanner Press SETUP, then follow on screen instructions to give your oil a name and change the new oil's TBN. NEX SETI Name=Oil Type 1 T- calibrate new oll UP- change name/TBN BACK SETUP NEXT Vv EDI EDIT Name=Oil Type 1 IT-to change New TBN=40 TBN-to change TBN NEXT v Vv NB: This screen only appears if a new oil TBN has previously been entered. Name=Sil Type 1 UP/DOWN-change NEXT-move cursor DOWN UP NEXT NEXT-to finish DOWN UP Name=Oil Type 1 New TBN=H0 UP/DOWN-change NEXT Name=Oil Type 1 NEXT- calibrate new oil SETUP- change name/TBN BACK SETUP NEXT Press NEXT to continue. > Follow out test instructions as for TBN Test on next page. Name=Oil Type 1 New TBN=55 Calibrated > The cell will confirm calibration after the graph has been plotted. Scanned with CamScanner @ @ Guide to Interpreting Results A full laboratory analysis should be considered if any monitored parameter approaches the relevant limit. Fuel Oils Water: <0.1% 0.1-0.25% >0.25% Check centrifuge. _ Distillate fuel operation, drain ser tank regularly. | Water: 20.25% 0.25-0.5% >1.0% | Residual fuel ee Lube Oils (0.15- ->0.20% Upper limit 0.2% checked against Sh **-- manufacturers’ da 4 tolerate water BEWARE! \ ‘Change | Always monitor TAI -#/-0,6 | trend as it can fluctu s the oil ages MA-K15688-KW Issue 1 Scanned with CamScanner Crank Case Oils Water in Oil <0.05% TBN- 2 to 12 | Crosshead TBN Engines TBN- Trunk >50% Piston Engines nominal | Salt Water 0% Viscosity 110% - 90% | nominal | Insotubles 0.5- 1% ESF ee Neti 0.05-0.4% 70.5% 1.751025 <1.75 TBN TBN or >25 TBN <50% nominal 20% >+/- 20% >120% nominal <90% nominal 1-2% >2% Check for fresh/salt water, eliminate leakage source and batch centrifuge sump charge. Partial renewal of lubricant charge. Check stuffing box seals for leakage of high TBN scavenge drains. Partial renewal of lubricant charge. Take immediate remedial action. Partial oil change. Check for fuel leaks into sump and fuel pump lubricating oil supply pressure. Check centrifuge operation, stuffing box seal, piston ring condition (by observation/blow down), Scanned with CamScanner Tx feel flea Enclosed Gears "Check viscosity frequently. Check correct "grade of oil is used for top up. | (cSt at 40°C) : fee Upper limit should be 0.05 = 0.15 - >0.20% checked against 0.15% 0.2% manufacturers’ data. Some oils cannot tolerate water - BEWARE! Water (%) ~ Always monitor TAN by _ trend as it can fluctuate _ as the oil ages. Refer to manufacturers | limits. Turbine Oil Usa! a, ERIE) ‘Action on Borderline Ze Oe [Viscosity — <#1-10% = ee Check viscosity — (cSt at 40°C) = nom frequently. Check correct | grade of oll is used for Ee | top up. Water (%) | 0.05- 0.15 - >0.20% Upper limit should be 0.15% 0.2% checked against manufacturers’ data. Some oils cannot tolerate water ~ BEWARE! | | | | <1100 | +10 42.0 Check for water — contamination at low \ \ levels, Scanned with CamScanner Compressor Oil Test S Parameter Always check: — inter-cooler drains are operated effectively. Refrigeration oils cannot tolerate water at all. “0.10% High insolubles wi Pe rapidly foul air delivery Stern Tube Oils 0.25 305% - 0.5% 4 ~ levels: Viscosity § _ >75% <75% - Linked with water: nominal nominal contamination. Consult manufacturers of seals and bearings. Use the Kittiwake Training Resource CD for guidance on fuels and lube oils. Help is also available at www. kittiwake.com "Scanned with CamScanner

You might also like