You are on page 1of 1

Midmark M7 SpeedClave®

Self-Contained Steam Sterilizer


The fastest and most efficient sterilizer available!
At only 11 1/2 minutes from a cold start, you won’t find a
faster conventional sterilizer than the Midmark M7
SpeedClave®. Starting hot, the M7 sterilizes unwrapped
instruments in just 9 minutes!

And, with constant improvements and new technology, the


M7’s reliability just keeps getting better. It meets U.L. Specifications
61010A-1 requirements. This self-contained unit sterilizes Overall length w/plug: 19" (48.3 cm)
wrapped or unwrapped instruments, linen packs and Overall width: 14" (35.6 cm)
glassware. Overall height: 13" (33 cm)
Countertop area: Minimum depth 16.5" (41.9 cm)
No plumbing is required as the M7 has its own reservoir for Chamber: 7.5" diameter (19.1 cm)
15" depth (38.1 cm)
distilled or demineralized water. For added convenience,
2.4 gal. usable volume (9.0 liters)
we’ve included three corrosion-resistant, stainless steel
trays. It’s also economically priced, making it not only the
Water reservoir capacity: 1.31 gal.
best, but the best product for your money. (4.9 liters)

Prevent “dry burning” Trays:


Low water cut-out switch prevents “dry burning”. The Two large – 5.62" W x 12" L x .88" D
M7 will operate only when there is enough water present, (14.3 cm x 30.5 cm x 2.2 cm)
which prolongs the life of the heating element. A pilot light One small – 4.12" W x 12" L x .88" D
is on when the heater is on and rotates off and on during (10.5 cm x 30.5 cm x 2.2 cm)
normal cycle.
Unit weight: 30 lbs. (13.6 kg)
Reset button saves time. Shipping weight: 34 lbs. (15.4 kg)
It restores operation after the cut-out switch is tripped and
you have added water. The cycle timer regulates steam time Electrical Requirements
115 VAC, 60 Hz, 10 AMPS Single phase
from 0 to 30 minutes and automatically turns the M7 115 VAC has 1136 watt tubular immersion heater
off when the sterilization cycle is complete. This prevents UL61010A-1 and CUL listed
over-sterilization thus extending the service life of CAN/CSA C22.2 No. 1010
your instruments. 230 VAC, 50 Hz, 5 AMPS Single phase
A separate (dedicated) circuit is recommended for this sterilizer.
A safety door protects the operator. Installation
It automatically seals when pressurized and will not allow Use on Formica®, stainless steel or stone surface.
the operator to open the door until the chamber is safely Allow 2.5" (6.4 cm) on sides and rear and 12" (30.5 cm) above,
to allow space to fill reservoir and for cooling processed trays.
depressurized. The temperature regulator allows the opera-
tor to preset the temperature at a desired setting between Formica is a registered trademark of Formica Corporation.
250˚F (121˚C) and 270˚F (132˚C). This control, acting as a
thermostat, cycles the heating element on and off. Midmark is an ISO 9001
Certified Company
A temperature gauge indicates the temperature inside the For more information
chamber. The gauge is graduated in two-degree increments or a demonstration, contact
from 80˚F (26.7˚C) to 270˚F (132˚C). your Midmark dealer or
Midmark Corporation,
Versailles, Ohio 45380.
Front Draining Feature
Call: 1-800-MIDMARK
With our front draining feature, it’s easy to clean
and maintain. All controls and information are on Fax: 1-877-725-6495
the front and easily accessible to the operator. midmark.com

© Midmark Corporation 2001


Products subject to improvement changes without notice.
Litho in U.S.A. 007-0164-00 Rev A1 (8/04)