Engineering Data
BPMKS967A3
BPMKS967A2
50 / 60 Hz
BPMKS967A3 / BPMKS967A2 EDFMT391758
BPMKS967A3 / BPMKS967A2
BP Units
50 / 60 Hz
1
BPMKS967A3 / BPMKS967A2 EDFMT391758
2
BPMKS967A3 / BPMKS967A2 EDFMT391758
2. Specifications
Notes:
1. The piping connection must be cut so as to suit the piping sizes of the indoor unit which will be connected.
The same sizes should be used for the piping on the outdoor unit.
2. ( )* : including auxiliary piping length
3
Unit: mm
25
BPMKS967A3
90
110
70
254
165
(304)
125
155
I.D.φ9.5 I.D.φ19. 1 45 Cut line for
I.D.φ15. 9
322
Suspension bolt pitch Cut line for
Cut line for I.D.φ12.7 For indoor side(Liquid)
Suspension bolt pitch Cut line for O.D.φ6. 4
Terminal(For A room) Wiring clamp For outdoor unit side(Gas) 150
2×3-Brazing (304) Wiring clamp Terminal(For B room) For outdoor unit side(Liquid)
45 Terminal(For C room) Electric box O.D.φ15.9 90 I.D.φ12.7
Terminal(For transmission) O.D.φ9.5 100 φ
I.D. 6.4
57 95 95 57
φ
3-I.D. 15.9CuT I.D. φ 19.1CuT I.D.φ9.5
Installation restrictions
(180)
(servicing space) (installation and service space) (servicing space)
Min460 Min390
23 73.5
23 73.5
3-I.Dφ.6.4CuT Terminal 2-Brazing
197 107
4
RoomA
RoomB
RoomC
Earth(M4) (For Power supply) Earth(M4) I.D.φ9.5CuT
178 294 178
INDOOR UNIT SIDE (650) OUTDOOR UNIT SIDE
Characteristics:
1. No drain treatment necessary.
2. This unit can be installed so that or side
faces forward. (It choosed by servicing direction).
3. The piping for the indoor unit and outdoor unit can be.
freely installed to directions of , , or . Wall-mounting
4. This unit can be installed with either suspending (Characteristic 4. ) Screw for temporary fixing
from the ceiling or mounting on wall. 323~355 (Cautions 3.)
25
Cautions: The opening for Inspection
Servicing is needed
1. This unit must be installed so that side of is facing up. opening of 650mm square
Min300
113
for service and maintenance.
for front and rear, right and left.
(servicing space)
3D048411A
BPMKS967A3 / BPMKS967A2 EDFMT391758
Unit: mm
25
BPMKS967A2
90
110
70
254
165
125
(304)
155
I.D.φ9.5 I.D.φ19.1 45 Cut line for
322 Cut line for I.D.φ15.9
Suspension bolt pitch Cut line for I.D.φ12.7 For indoor side(Liquid)
Suspension bolt pitch Cut line for O.D.φ6.4
Terminal(For A room) Wiring clamp For outdoor unit side(Gas) 150
2×2-Brazing Terminal(For B room) For outdoor unit side(Liquid)
(304) 45 Wiring clamp Electric box O.D.φ15.9 90 I.D.φ12.7 100
Terminal(For transmission) O.D.φ9.5 I.D.φ6.4
57 95
2-I.D.φ15.9CuT I.D. φ 19.1CuT I.D.φ9.5
Installation restrictions
(180)
(servicing space) (installation and service space) (servicing space)
Min390 Min390
23 73.5
23 73.5
2-I.D.φ6.4CuT 2-Brazing
Terminal 197 107
5
Earth(M4) (For Power supply) Earth(M4) I.D.φ9.5CuT
RoomA
RoomB
178 294 178
INDOOR UNIT SIDE (650) OUTDOOR UNIT SIDE
Characteristics:
1. No drain treatment necessary.
2. This unit can be installed so that or side
faces forward. (It choosed by servicing direction).
3. The piping for the indoor unit and outdoor unit can be.
freely installed to directions of , , or . Wall-mounting
4. This unit can be installed with either suspending Screw for temporary fixing
from the ceiling or mounting on wall. (Characteristic 4. )
323~355 (Cautions 3.)
25
Cautions: The opening for Inspection
1. This unit must be installed so that side of is facing up. Servicing is needed
opening of 650mm square
Min300
113
for front and rear, right and left. for service and maintenance.
(servicing space)
3D048412A
BPMKS967A3 / BPMKS967A2 EDFMT391758
BPMKS967A3 / BPMKS967A2 EDFMT391758
4. Piping Diagrams
BPMKS967A3
INDOOR UNIT
GAS SIDE
THERMISTOR(DGA) ROOM A
(15.9CuT)
LOCAL PIPING
GAS SIDE
REFRIGERANT FLOW THERMISTOR(DGB) ROOM B
(15.9CuT) GAS
HEATING
LOCAL PIPING
COOLING GAS SIDE
THERMISTOR(DGC) ROOM C
(15.9CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(BYPASS)
FILTER EVH ELECTRONIC INDOOR UNIT
EXPANSION VALVE(ROOM A)
LIQUID SIDE
EVA FILTER THERMISTOR(DLA) ROOM A
(6.4CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(ROOM B)
LIQUID SIDE
EVB FILTER THERMISTOR(DLB) ROOM B
(6.4CuT)
OUTDOOR UNIT LIQUID
(19.1CuT) LOCAL PIPING
ELECTRONIC
LOCAL PIPING EXPANSION VALVE(ROOM C)
LIQUID SIDE
EVC FILTER THERMISTOR(DLC) ROOM C
(6.4CuT)
LOCAL PIPING
3D048285A
BPMKS967A2
INDOOR UNIT
GAS SIDE ROOM A
REFRIGERANT FLOW THERMISTOR(DGA) (15.9CuT)
HEATING LOCAL PIPING
COOLING GAS SIDE GAS
THERMISTOR(DGB) ROOM B
(15.9CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(BYPASS)
FILTER ELECTRONIC INDOOR UNIT
EVH EXPANSION VALVE(ROOM A)
LIQUID SIDE
EVA FILTER THERMISTOR(DLA) ROOM A
(6.4CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(ROOM B) LIQUID
LIQUID SIDE
EVB FILTER THERMISTOR(DLB) ROOM B
(6.4CuT)
OUTDOOR UNIT
(19.1CuT) LOCAL PIPING
LOCAL PIPING
LOCAL PIPING
3D048286B
6
BPMKS967A3 / BPMKS967A2 EDFMT391758
5. Wiring Diagrams
BPMKS967A3
3D048288
BPMKS967A2
3D048438
7
BPMKS967A3 / BPMKS967A2 EDFMT391758
6. Electric Characteristics
Symbols:
MCA : Min. Circuit Amps (A)
MFA : Max. Fuse Amps (A) (See Note 5)
kW : Fan Motor Rated Output (kW)
FLA : Full Load Amps (A)
IFM : Indoor Fan Motor
Notes:
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA / MFA
MCA = 1.25 × FLA
MFA ≤ 4 × FLA
(Next lower standard fuse rating. Min. 15 A)
4. Select wire size based on the MCA.
5. Instead of fuse, use circuit breaker.
6. Regarding the power supply, refer to the power supply of BP units.
Power supply intake is from BP units.
8
BPMKS967A3 / BPMKS967A2 EDFMT391758
7. Centre of Gravity
BPMKS967A3
Unit: mm
3D048409A
BPMKS967A2
Unit: mm
3D048410A
9
BPMKS967A3 / BPMKS967A2 EDFMT391758
8. Accessories
8.1 Optional Accessories
Model
Item
BPMKS967A3 BPMKS967A2
REFNET joint KHRP26A22T
Note:
A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
10
BPMKS967A3 / BPMKS967A2 EDFMT391758
9. 01_EN_3P155399-1E.fm
Installation Manual
Page 1 Monday, March 7, 2011 10:30 AM
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION .............. Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use
and cleaning of the unit according to the Operation Manual.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electrical shock or fire.)
• Use the specified types of wires for electrical connections from the BP unit to the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal
overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the shut-off valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the shut-off valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish a ground. Do not ground the unit to a utility pipe, arrester, or telephone ground.
Incomplete ground may cause electrical shock. A high surge current from lightning or other sources may cause damage to the air
conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electrical shocks.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• This unit is for indoor use.
(If installing outdoors, place in a location away from wind and rain.)
English 1
3P155399-1E
11
BPMKS967A3 / BPMKS967A2 EDFMT391758
Accessories
6 For indoor unit side piping (gas) BPMKS967A3
1 Installation Manual (pipe joint) (For 3 rooms)
: 3pcs.
1pc.
BPMKS967A2
(For 2 rooms)
: 2pcs.
2 For outdoor unit side piping (gas)
7 Hanger metal
(pipe joint)
1pc. 4pcs.
(*) Only in protected pipes, use H07RN-F when protected pipes are not use.
Specifications for local wiring power cord and branch wiring are in compliance with IEC60245.
English 3
3P155399-1E
12
BPMKS967A3 / BPMKS967A2 EDFMT391758
Installation
• This unit may be installed suspended from the ceiling or mounted on the wall.
• This unit may only be installed, as shown in the diagram below. (The side should be facing upwards.)
However, it may be freely installed in any direction forward or back, and to the sides.
• Be sure to leave a 650mm square opening for service and inspection as shown in the diagram below, for both ceiling-
suspended installation and wall-mounted installation.
• This unit “does not require drain treatment”.
• This unit may be installed with sides or facing forward (servicing direction).
• The piping for the indoor unit may be freely led around in directions , , or .
• The inclination of side must be within ±5°C degrees forward or back or to the sides.
For 2 rooms
(product dimensions and attachment bolt pitch) Wall-mounted
113 (25)
Indoor unit side
piping Manufacturer’s label 4-Suspension bolt
25
(M8-M10)
(304)
254
322
Suspension bolt pitch Suspension bolt pitch
Terminal (For A room)
2×2-Brazing Wiring clamp Terminal (For B room) Wiring clamp
(304) 45 Electric box
57 95 Terminal (For transmission) (Top surface)
2-I.D. φ15.9 CuT
I.D. φ19.1 CuT
(180)
73.5
73.5
23
2-I.D. φ6.4 CuT
23
Terminal 2-Brazing
Room A
Room B
Earth (M4) (For Power supply) Earth (M4) I.D. φ9.5 CuT 197 107
178 294 178
(650)
INDOOR UNIT SIDE OUTDOOR UNIT SIDE
110
70
165
125
155
English 5
C: 3P155399-1E
13
BPMKS967A3 / BPMKS967A2 EDFMT391758
Installation
For 3 rooms
(product dimensions and attachment bolt pitch) Wall-mounted
113 (25)
Indoor unit side
piping Manufacturer’s label 4-Suspension bolt
25
(M8-M10)
(304)
254
322
Suspension bolt pitch Suspension bolt pitch
Terminal (For A room)
2×3-Brazing Wiring clamp Terminal (For B room) Wiring clamp
(304) 45
Terminal (For C room) Electric box
57 95 95 57 Terminal (For transmission) (Top surface)
3-I.D. φ15.9 CuT
I.D. φ19.1 CuT
(180)
73.5
73.5
23
3-I.D. φ6.4 CuT
23
Terminal 2-Brazing
Room C
Room A
Room B
Earth (M4) (For Power supply) Earth (M4) I.D. φ9.5 CuT 197 107
178 294 178
(650)
INDOOR UNIT SIDE OUTDOOR UNIT SIDE
110
70
165
125
155
6 English
3P155399-1E
14
BPMKS967A3 / BPMKS967A2 EDFMT391758
Caution
• Before doing any wiring on site, replace the electric box.
Electrical equipment
cover
Screw (M4×12L)
2) Remove 4 screws shown in the figure on the below, remove Remove 4 screws. (M4×8L)
the printed circuit board.
4
4
4
P
(A)
(A)
(B)
Binding band
English 7
3P155399-1E
15
BPMKS967A3 / BPMKS967A2 EDFMT391758
Insert the
tabs fully.
2. Ceiling-suspended type
Screws 8
Hanger metal 7
Procedure:
1) Fix the furnished hanger metal 7 with two screws 8 .
(4 locations in total)
2) Using an insert-hole-in-anchor, hang the hanging bolt.
3) Install a hexagon nut and a flat washer (field supply) to
the hanging bolt as shown in the figure in the below,
and lift the unit to hang on the hanger metal. Ceiling side
4) After checking with a level that the unit is level, tighten
the hexagon nut.
* The tilt of the unit should be within ±5° in front/ back
and left/right.
Hanging bolt (M10 or M8)
Six-sided nut (M10 or M8)
15~20
Flat washer
Nut
Flat washer
Hanger metal 7
Hanging bolt BP unit
CAUTION
• Be sure to install the unit with the top surface up. Temporary screw:
Screw in temporarily after
• Do not install near bedrooms. The sound of refrigerant opening a slight gap with
flowing through the piping may sometimes be audible. the wall.
Temporary screws:
attach and then hang the Screws (M5)
unit on them. (2 screws) (field supply)
8 English
3P155399-1E
16
BPMKS967A3 / BPMKS967A2 EDFMT391758
Heat
insulation 10
3) Wrap the pipes to be brazed with sufficient wet cloths so that brazing
does not affect the unit.
Wet cloth
4) After brazing, use wet cloths or spray mist to sufficiently cool off all
pipes.
brazing
5) When brazing, be careful that the flame of the torch does not come in
contact with the unit.
(Since the inside of the unit is made of plastic, it may become
deformed or melt, destroying its heat-insulation performance.)
Wet cloth
2. Insulation of pipes
1) Attach heat insulation to each pipe. One-sided adhesive tape
(field supply)
2) When attaching insulation to the pipes, use one-sided adhesive tape or
similar materials to thoroughly prevent air from entering the heat
Heat insulation
insulation. (field supply)
3) Eliminate any gaps in the heat insulation.
Heat insulation 10
3. Unconnected pipes
Wet cloth
1) For pipes not yet connected to a room, pinch the end of the pipe and
braze them. brazing
2) When brazing this area too, wrap the pipes with sufficient wet cloths to
protect the unit.
3) After brazing this area too, cool the pipes sufficiently.
Wet cloth
brazing
4) Attach heat insulation, and use one-sided adhesive tape to thoroughly
prevent air from entering the heat insulation.
One-sided adhesive tape
5) Cover the ends of the pipes with sufficient heat insulation. (field supply)
Heat insulation
(field supply)
English 9
3P155399-1E
17
BPMKS967A3 / BPMKS967A2 EDFMT391758
125
Pipe joint 6
Brazing Piping
Piping Piping Pipe joint 3 (field supply)
(field supply) Brazing (field supply)
I.D φ9.5 I.D φ12.7
When straight. When the direction is changed.
I.D φ15.9 I.D φ12.7
Brazing Brazing
Connection for φ15.9 piping. Connection for φ12.7 piping.
When straight.
Indoor unit side (Liquid)
45
Pipe joint 5
Cut line Pipe joint 2 Cut line for
Brazing
for O.D φ6.4 I.D φ15.9
Piping
Piping Piping (field supply)
I.D φ9.5
(field supply) (field supply) I.D φ19.1
Pipe joint 3
Connecting φ9.5 I.D φ12.7
45
Brazing Brazing
interunit piping
Cut line for
I.D φ15.9
Outdoor unit side (Liquid) Connection for φ19.1 and φ15.9 piping. Connection for φ12.7 piping.
Brazing
I.D φ6.4 NOTE
When changing the direction of the piping to
Connecting φ6.4
something other than the above, bend the
interunit piping
piping on site.
10 English
3P155399-1E
18
BPMKS967A3 / BPMKS967A2 EDFMT391758
Pattern 1 N2 Pattern 2 N2
L2 BP unit L2 BP unit
N1 3 Power N1 3
L1 voltage L1
N2 N2
L2 BP unit L2 BP unit
N1 2 Power N1 2
L1 voltage L1
N2 N2
L2 BP unit L2 BP unit
Power N1 1 Power N1 1
voltage L1 voltage L1
Screw (M4×12L)
2) Tape is attached to the wire binding band. The purpose of the tape is to prevent small animals from entering the unit.
Only remove the tape from places where wiring it to be passed through.
CAUTION
If the tape is not replaced for
places where wiring will not pass
through, small animals may enter,
causing product malfunction.
4
The tape to
4
of small animals
P
The tape to
prevent The tape to prevent the entry of small animals
the entry of Wire clamp Wire clamp
(tape is attached when unit is shipped to
small animals prevent animals from entering the unit)
English 11
C: 3P155399-1E
19
BPMKS967A3 / BPMKS967A2 EDFMT391758
NOTE: The terminal block numbers are arranged from top to bottom in order of 1, 2 and 3.
Peel the outer coating leaving Binding band 9
10mm from the wire clamp. Example Secure the wires with binding band 9 to Warning
prevent them from coming out if pulled Do not use tapped
10mm 〈For 3 rooms〉 on from the outside.
wires,stand wires,
extensioncords, or
starbust connections,
Wire as they may cause
clamp overtheating, electrical
shock, or fire.
1
2 Room A Transmission wire (To other BP unit: F1, F2)
3
4
F1 Wire clamp
3
For other BP unit (To L1, N1)
4
1 N2
P
2 Room C L2 CAUTION
N1
4
3 Mistakenly connecting the power
L1
supply to this terminal block could
cause control operating malfunctions.
(*) Only in protected pipes, use H07RN-F when protected pipes are not use.
Specifications for local wiring power cord and branch wiring are in compliance with IEC60245.
CAUTION
• All local interunit wiring must be secured using the wire
binding band over the insulation, as shown in the figure. Insulation
12 English
3P155399-1E
20
BPMKS967A3 / BPMKS967A2 EDFMT391758
+300mm
of slack
+300mm
of slack
5) Return the electrical equipment cover to its original position, and fix it with the
screws.
Screw
(M4×12L)
Install the electrical
equipment cover.
Operating Test
Follow the “Operating test” as described in the installation manual of the outdoor unit.
If the BP unit does not operate normally during the test run, the error can be checked on the remote controller display for the indoor
unit.
The BP Unit
Simple diagnosis can be done using the LEDs on the BP unit’s circuit board.
For details, see the label on the inside of the BP unit’s electrical equipment cover.
English 13
3P155399-1E
21
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
●Specifications, designs and other content appearing in this brochure are current as of October 2017 but subject to change without notice.