EDFMT391758

201710

Engineering Data

BPMKS967A3
BPMKS967A2
50 / 60 Hz
BPMKS967A3 / BPMKS967A2 EDFMT391758

BPMKS967A3 / BPMKS967A2
BP Units
50 / 60 Hz

1. Lineup and Power Supply...........................................................................2


2. Specifications..............................................................................................3
3. Dimensions..................................................................................................4
4. Piping Diagrams..........................................................................................6
5. Wiring Diagrams..........................................................................................7
6. Electric Characteristics................................................................................8
7. Centre of Gravity.........................................................................................9
8. Accessories...............................................................................................10
8.1 Optional Accessories.......................................................................10
9. Installation Manual....................................................................................11
9.1 BPMKS967A3 / BPMKS967A2........................................................11

1
BPMKS967A3 / BPMKS967A2 EDFMT391758

1. Lineup and Power Supply

Type Model name Power supply


3 ports BPMKS967A3 1 phase,
220-240/220-230 V,
2 ports BPMKS967A2 50/60 Hz

BPMKS967A3 (3 ports) BPMKS967A2 (2 ports)

2
BPMKS967A3 / BPMKS967A2 EDFMT391758

2. Specifications

Model BPMKS967A3 BPMKS967A2


Power supply 1 phase, 220-240/220-230 V, 50/60 Hz 1 phase, 220-240/220-230 V, 50/60 Hz
Connectable indoor units 1~3 units 1~2 units
Casing color Paintingless Paintingless
Power input W 10 10
Running current A 0.05 0.05
Refrigerant type R410A R410A
Dimension (H×W×D) mm 180×294(650)*×350 180×294(650)*×350
Package dimension (H×W×D) mm 257×738×427 257×738×427
Machine weight kg 8 7.5
Gross weight kg 12 11
3 for power supply (include each wiring), 2 for 2 for power supply (include each wiring), 2 for
Number of wiring connections interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (outdoor unit-BP, BP-BP), 3 for
interunit wiring (BP-indoor unit) interunit wiring (BP-indoor unit)
Liquid mm Main : φ9.5×1 / Branch : φ6.4×3 Main : φ9.5×1 / Branch : φ6.4×2
Piping
connection Gas mm Main : φ19.1×1 / Branch : φ15.9×3 Main : φ19.1×1 / Branch : φ15.9×2
(Brazing)
Drain mm Drain processingless Drain processingless
Heat insulation Both liquid and gas pipes Both liquid and gas pipes
Max. combination kW 20.8 14.2
kW 2.0 (For 2.0 kW class residential indoor units) 2.0 (For 2.0 kW class residential indoor units)
Min. combination
kW 2.5 (For 2.5 kW class residential indoor units) 2.5 (For 2.5 kW class residential indoor units)
Installation manual pc. 1 1
Liquid 1 (for I.D. φ6.4) 1 (for I.D. φ6.4)
For
main Gas 1 (for I.D. φ12.7) 1 (for I.D. φ12.7)
L shape Gas pc. 1 (for I.D. φ15.9, 19.1) 1 (for I.D. φ15.9, 19.1)
reducer
For Liquid 1 (for I.D. φ9.5) 1 (for I.D. φ9.5)
Accessories branch Gas
3 (for I.D. φ12.7, 9.5) 2 (for I.D. φ12.7, 9.5)
Hanger metal pc. 4 4
Screws pc. 8 (M4×8) 8 (M4×8)
Heat insulation 4 set 3 set
(2pcs. is 1 set)
Binding band pc. 2 2
Drawing No. C: 4D050057B C: 4D050057B

Notes:
1. The piping connection must be cut so as to suit the piping sizes of the indoor unit which will be connected.
The same sizes should be used for the piping on the outdoor unit.
2. ( )* : including auxiliary piping length

3
Unit: mm

(Characteristic 3. ) Manufacturer's 4-Suspension


Branch piping label bolt(M8~M10) Standard accessories(Caution5. )

25
BPMKS967A3

68 For indoor side(Gas) For outdoor side(Gas)


163 110
258 Dimple
O.D.φ15.9 65 O.D.φ19. 1
3. Dimensions

90
110

70

254
165

(304)
125

155
I.D.φ9.5 I.D.φ19. 1 45 Cut line for
I.D.φ15. 9
322
Suspension bolt pitch Cut line for
Cut line for I.D.φ12.7 For indoor side(Liquid)
Suspension bolt pitch Cut line for O.D.φ6. 4
Terminal(For A room) Wiring clamp For outdoor unit side(Gas) 150
2×3-Brazing (304) Wiring clamp Terminal(For B room) For outdoor unit side(Liquid)
45 Terminal(For C room) Electric box O.D.φ15.9 90 I.D.φ12.7
Terminal(For transmission) O.D.φ9.5 100 φ
I.D. 6.4
57 95 95 57
φ
3-I.D. 15.9CuT I.D. φ 19.1CuT I.D.φ9.5

Installation restrictions

(180)
(servicing space) (installation and service space) (servicing space)
Min460 Min390

23 73.5

23 73.5
3-I.Dφ.6.4CuT Terminal 2-Brazing
197 107

4
RoomA
RoomB
RoomC
Earth(M4) (For Power supply) Earth(M4) I.D.φ9.5CuT
178 294 178
INDOOR UNIT SIDE (650) OUTDOOR UNIT SIDE

Characteristics:
1. No drain treatment necessary.
2. This unit can be installed so that or side
faces forward. (It choosed by servicing direction).
3. The piping for the indoor unit and outdoor unit can be.
freely installed to directions of , , or . Wall-mounting
4. This unit can be installed with either suspending (Characteristic 4. ) Screw for temporary fixing
from the ceiling or mounting on wall. 323~355 (Cautions 3.)

25
Cautions: The opening for Inspection
Servicing is needed
1. This unit must be installed so that side of is facing up. opening of 650mm square
Min300

2. The slant of face must be within ±5°

113
for service and maintenance.
for front and rear, right and left.
(servicing space)

3. Before mounting on the wall , installation becomes easy


by hanging this unit on screw for temporary fixing. (2 places)
4. At the time of brazing the pipes, wrap the pipes with : screw for fixing.(4 places)
sufficient wet cloths.
And after brazing also, must cool piping enough.
5. Cut the piping of the standard accessories in order to
match the indoor unit's piping diameter.

3D048411A
BPMKS967A3 / BPMKS967A2 EDFMT391758
Unit: mm

(Characteristic 3. ) Manufacturer's 4-Suspension


Branch piping label bolt(M8~M10) Standard accessories (Caution5. )

25
BPMKS967A2

68 For indoor side(Gas) For outdoor side(Gas)


163 110
Dimple
O.D.φ15.9 65 O.D.φ19.1

90
110

70

254
165

125

(304)
155
I.D.φ9.5 I.D.φ19.1 45 Cut line for
322 Cut line for I.D.φ15.9
Suspension bolt pitch Cut line for I.D.φ12.7 For indoor side(Liquid)
Suspension bolt pitch Cut line for O.D.φ6.4
Terminal(For A room) Wiring clamp For outdoor unit side(Gas) 150
2×2-Brazing Terminal(For B room) For outdoor unit side(Liquid)
(304) 45 Wiring clamp Electric box O.D.φ15.9 90 I.D.φ12.7 100
Terminal(For transmission) O.D.φ9.5 I.D.φ6.4
57 95
2-I.D.φ15.9CuT I.D. φ 19.1CuT I.D.φ9.5

Installation restrictions

(180)
(servicing space) (installation and service space) (servicing space)
Min390 Min390

23 73.5

23 73.5
2-I.D.φ6.4CuT 2-Brazing
Terminal 197 107

5
Earth(M4) (For Power supply) Earth(M4) I.D.φ9.5CuT

RoomA
RoomB
178 294 178
INDOOR UNIT SIDE (650) OUTDOOR UNIT SIDE

Characteristics:
1. No drain treatment necessary.
2. This unit can be installed so that or side
faces forward. (It choosed by servicing direction).
3. The piping for the indoor unit and outdoor unit can be.
freely installed to directions of , , or . Wall-mounting
4. This unit can be installed with either suspending Screw for temporary fixing
from the ceiling or mounting on wall. (Characteristic 4. )
323~355 (Cautions 3.)

25
Cautions: The opening for Inspection
1. This unit must be installed so that side of is facing up. Servicing is needed
opening of 650mm square
Min300

2. The slant of face must be within ±5°

113
for front and rear, right and left. for service and maintenance.
(servicing space)

3. Before mounting on the wall , installation becomes easy


by hanging this unit on screw for temporary fixing. (2 places)
4. At the time of brazing the pipes, wrap the pipes with :screw for fixing. (4 places)
sufficient wet cloths.
And after brazing also, must cool piping enough.
5. Cut the piping of the standard accessories in order to
match the indoor unit's piping diameter.

3D048412A
BPMKS967A3 / BPMKS967A2 EDFMT391758
BPMKS967A3 / BPMKS967A2 EDFMT391758

4. Piping Diagrams

BPMKS967A3

INDOOR UNIT
GAS SIDE
THERMISTOR(DGA) ROOM A
(15.9CuT)
LOCAL PIPING
GAS SIDE
REFRIGERANT FLOW THERMISTOR(DGB) ROOM B
(15.9CuT) GAS
HEATING
LOCAL PIPING
COOLING GAS SIDE
THERMISTOR(DGC) ROOM C
(15.9CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(BYPASS)
FILTER EVH ELECTRONIC INDOOR UNIT
EXPANSION VALVE(ROOM A)
LIQUID SIDE
EVA FILTER THERMISTOR(DLA) ROOM A
(6.4CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(ROOM B)
LIQUID SIDE
EVB FILTER THERMISTOR(DLB) ROOM B
(6.4CuT)
OUTDOOR UNIT LIQUID
(19.1CuT) LOCAL PIPING
ELECTRONIC
LOCAL PIPING EXPANSION VALVE(ROOM C)
LIQUID SIDE
EVC FILTER THERMISTOR(DLC) ROOM C
(6.4CuT)
LOCAL PIPING

OUTDOOR UNIT FILTER


(9.5CuT)
LOCAL PIPING

3D048285A

BPMKS967A2

INDOOR UNIT
GAS SIDE ROOM A
REFRIGERANT FLOW THERMISTOR(DGA) (15.9CuT)
HEATING LOCAL PIPING
COOLING GAS SIDE GAS
THERMISTOR(DGB) ROOM B
(15.9CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(BYPASS)
FILTER ELECTRONIC INDOOR UNIT
EVH EXPANSION VALVE(ROOM A)
LIQUID SIDE
EVA FILTER THERMISTOR(DLA) ROOM A
(6.4CuT)
LOCAL PIPING
ELECTRONIC
EXPANSION VALVE(ROOM B) LIQUID
LIQUID SIDE
EVB FILTER THERMISTOR(DLB) ROOM B
(6.4CuT)
OUTDOOR UNIT
(19.1CuT) LOCAL PIPING
LOCAL PIPING

OUTDOOR UNIT FILTER


(9.5CuT)

LOCAL PIPING

3D048286B

6
BPMKS967A3 / BPMKS967A2 EDFMT391758

5. Wiring Diagrams

BPMKS967A3

3D048288

BPMKS967A2

3D048438

7
BPMKS967A3 / BPMKS967A2 EDFMT391758

6. Electric Characteristics

Units Power supply IFM Input (W)


Model Hz Volts Voltage range MCA MFA kW FLA Cooling Heating
BPMKS967A3 Max. 264 V 0.05 15 — — 10 10
50 Hz 220-240 V Min. 198 V
BPMKS967A2 0.05 15 — — 10 10
BPMKS967A3 Max. 253 V 0.05 15 — — 10 10
60 Hz 220-230 V
BPMKS967A2 Min. 198 V 0.05 15 — — 10 10

Symbols:
MCA : Min. Circuit Amps (A)
MFA : Max. Fuse Amps (A) (See Note 5)
kW : Fan Motor Rated Output (kW)
FLA : Full Load Amps (A)
IFM : Indoor Fan Motor

Notes:
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA / MFA
MCA = 1.25 × FLA
MFA ≤ 4 × FLA
(Next lower standard fuse rating. Min. 15 A)
4. Select wire size based on the MCA.
5. Instead of fuse, use circuit breaker.
6. Regarding the power supply, refer to the power supply of BP units.
Power supply intake is from BP units.

8
BPMKS967A3 / BPMKS967A2 EDFMT391758

7. Centre of Gravity

BPMKS967A3

Unit: mm

3D048409A

BPMKS967A2

Unit: mm

3D048410A

9
BPMKS967A3 / BPMKS967A2 EDFMT391758

8. Accessories
8.1 Optional Accessories

Model
Item
BPMKS967A3 BPMKS967A2
REFNET joint KHRP26A22T

Note:
A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.

10
BPMKS967A3 / BPMKS967A2 EDFMT391758

9. 01_EN_3P155399-1E.fm
Installation Manual
Page 1 Monday, March 7, 2011 10:30 AM

9.1 BPMKS967A3 / BPMKS967A2

Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

CAUTION .............. Failure to follow any of CAUTION may in some cases result in grave consequences.
• The following safety symbols are used throughout this manual:

Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.

• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use
and cleaning of the unit according to the Operation Manual.

WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electrical shock or fire.)
• Use the specified types of wires for electrical connections from the BP unit to the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal
overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the shut-off valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the shut-off valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish a ground. Do not ground the unit to a utility pipe, arrester, or telephone ground.
Incomplete ground may cause electrical shock. A high surge current from lightning or other sources may cause damage to the air
conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electrical shocks.

CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• This unit is for indoor use.
(If installing outdoors, place in a location away from wind and rain.)

„English 1

3P155399-1E

11
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 3 Monday, March 7, 2011 10:30 AM

Accessories
6 For indoor unit side piping (gas) BPMKS967A3
1 Installation Manual (pipe joint) (For 3 rooms)
: 3pcs.
1pc.
BPMKS967A2
(For 2 rooms)
: 2pcs.
2 For outdoor unit side piping (gas)
7 Hanger metal
(pipe joint)
1pc. 4pcs.

3 For outdoor unit side piping (gas)


8 Screws
(pipe joint)
1pc. 8pcs.

4 For outdoor unit side piping (liquid)


9 Binding band
(pipe joint)
1pc. 2pcs.

5 For indoor unit side piping (liquid) BPMKS967A3


10 Heat insulation (2pcs. is 1set) (For 3 rooms)
(pipe joint)
: 4sets
1pc.
BPMKS967A2
(For 2 rooms)
: 3sets

Items to be prepared in the field


• Connecting wires between BP unit and indoor unit (H05VV(*), 4 wires, 1.6mm or 2.0mm)
• Connecting wires (H05VV(*), 3 wires, 1.6mm or 2.0mm)
• Transmission wires (sheathed two-core cables of 0.75mm² to 1.25mm²)
• Installation parts (hanging bolts: 4 × M10 or M8; nuts: 8; flat washers: 8)
• Screws for wall-mounting: 6 × M5
• Heat insulation (joint) [Thermal conductivity: 0.041 - 0.052W/mK (0.035 - 0.045kcal/mh°C) or more / thickness 13mm
(1/2 inch) or more / Heat resistance: 100°C or higher (Only heat pump system)]

(*) Only in protected pipes, use H07RN-F when protected pipes are not use.
Specifications for local wiring power cord and branch wiring are in compliance with IEC60245.

Precautions for Selecting the Location


The BP unit is for indoor use.
Install in a location such as above a ceiling or behind a wall in accordance with the following conditions:
• That the unit is fully supported, and is in a location with little or no vibration.
• That the refrigerant pipes for the indoor and outdoor units can be repaired with ease, and that the units are placed well within
the distance from each other allowed by the pipe length.
• That there is nothing nearby that produces heat or steam (gas).
• When installing, that there is enough room for servicing the unit.
• Do not install in location that is hot or humid for long periods of time.
A location where the dry-bulb (DB) temperature around the BP unit reaches 60°C or higher.
• A well-ventilated area.
• Do not install near bedrooms. The sound of refrigerant flowing through the piping may sometimes be audible.
For restrictions on installation, refer to P5~6. “Installation”.

„English 3

3P155399-1E

12
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 5 Monday, March 7, 2011 10:30 AM

Installation
• This unit may be installed suspended from the ceiling or mounted on the wall.
• This unit may only be installed, as shown in the diagram below. (The side should be facing upwards.)
However, it may be freely installed in any direction forward or back, and to the sides.
• Be sure to leave a 650mm square opening for service and inspection as shown in the diagram below, for both ceiling-
suspended installation and wall-mounted installation.
• This unit “does not require drain treatment”.
• This unit may be installed with sides or facing forward (servicing direction).
• The piping for the indoor unit may be freely led around in directions , , or .
• The inclination of side must be within ±5°C degrees forward or back or to the sides.

For 2 rooms
(product dimensions and attachment bolt pitch) Wall-mounted

113 (25)
Indoor unit side
piping Manufacturer’s label 4-Suspension bolt
25

(M8-M10)
(304)
254

322
Suspension bolt pitch Suspension bolt pitch
Terminal (For A room)
2×2-Brazing Wiring clamp Terminal (For B room) Wiring clamp
(304) 45 Electric box
57 95 Terminal (For transmission) (Top surface)
2-I.D. φ15.9 CuT
I.D. φ19.1 CuT
(180)
73.5

73.5
23
2-I.D. φ6.4 CuT
23

Terminal 2-Brazing
Room A

Room B

Earth (M4) (For Power supply) Earth (M4) I.D. φ9.5 CuT 197 107
178 294 178
(650)
INDOOR UNIT SIDE OUTDOOR UNIT SIDE

Installation restrictions Standard accessories


(Installation and service space)
(Servicing space) (Servicing space) 68 For indoor unit side (Gas) For outdoor unit side (Gas)
Min 390 Min 390 163 O.D.
Dimple 110
65 φ19.1
O.D. φ15.9
90

110
70

165
125
155

I.D. φ9.5 I.D. φ19.1 45 Cut line for


I.D. φ15.9
Cut line for Cut line for
I.D. φ12.7
For outdoor unit side (Gas) For indoor unit side (Liquid)
(Servicing space)

O.D. I.D. Cut line for O.D. φ6.4


Min 300

The opening for Inspection


90 150
Servicing is needed opening φ15.9 φ12.7
of 650mm square for For outdoor unit side (Liquid)
service and maintenance.
O.D. 100 I.D.
φ9.5 φ6.4 I.D. φ9.5

„English 5

C: 3P155399-1E

13
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 6 Monday, March 7, 2011 10:30 AM

Installation

For 3 rooms
(product dimensions and attachment bolt pitch) Wall-mounted

113 (25)
Indoor unit side
piping Manufacturer’s label 4-Suspension bolt
25

(M8-M10)
(304)
254

322
Suspension bolt pitch Suspension bolt pitch
Terminal (For A room)
2×3-Brazing Wiring clamp Terminal (For B room) Wiring clamp
(304) 45
Terminal (For C room) Electric box
57 95 95 57 Terminal (For transmission) (Top surface)
3-I.D. φ15.9 CuT
I.D. φ19.1 CuT
(180)
73.5

73.5
23
3-I.D. φ6.4 CuT
23

Terminal 2-Brazing
Room C
Room A

Room B

Earth (M4) (For Power supply) Earth (M4) I.D. φ9.5 CuT 197 107
178 294 178
(650)
INDOOR UNIT SIDE OUTDOOR UNIT SIDE

Installation restrictions Standard accessories


(Installation and service space)
(Servicing space) (Servicing space) 68 For indoor unit side (Gas) For outdoor unit side (Gas)
Min 460 Min 390 163 O.D.
Dimple 110
258 φ19.1
O.D. φ15.9 65
90

110
70

165
125
155

I.D. φ9.5 I.D. φ19.1 45 Cut line for


I.D. φ15.9
Cut line for Cut line for
I.D. φ12.7
For outdoor unit side (Gas) For indoor unit side (Liquid)
(Servicing space)

O.D. I.D. Cut line for O.D. φ6.4


Min 300

The opening for Inspection


90 150
Servicing is needed opening φ15.9 φ12.7
of 650mm square for For outdoor unit side (Liquid)
service and maintenance.
O.D. 100 I.D.
φ9.5 φ6.4 I.D. φ9.5

6 „English

3P155399-1E

14
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 7 Monday, March 7, 2011 10:30 AM

Installation of the Unit


1. Replacing the electric box
• This unit has two different installation types:
(1) ceiling-suspended type and (2) wall-mounted type. Printed circuit board
• Choose the proper installation pattern according to the Reverse
location of installation. position
• The installation location for the printed circuit board can
be changed.
• Procedure for changing the installation location of Printed
Indoor circuit board
the printed circuit board. unit side
If the installation location of the printed circuit board pipe
As-shipped condition After-location is changed
needs to be changed because of the installation
conditions, perform the following:

Caution
• Before doing any wiring on site, replace the electric box.

1) Remove the screws and pull off the electrical equipment


cover.

Electrical equipment
cover
Screw (M4×12L)
2) Remove 4 screws shown in the figure on the below, remove Remove 4 screws. (M4×8L)
the printed circuit board.
4
4

4
P

3) Remove the binding band (A) which holds the wires.


Binding band 4

Printed circuit board

(A)

Press on the protrusion (B)


and pull out.

4) Remove the printed circuit board, and reattach as shown in


Top surface of the unit
the figure.
Lift the tabs.
To opposite side

5) Reattach the binding band to position (B).


Printed circuit board

(A)

(B)

Binding band

„English 7

3P155399-1E

15
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 8 Monday, March 7, 2011 10:30 AM

Installation of the Unit


6) Attach the printed circuit board and electrical equipment Printed circuit board
cover to the other side and secure with the screws.
Electrical
Top surface of the unit
equipment
cover

Insert the
tabs fully.

2. Ceiling-suspended type
Screws 8
Hanger metal 7
Procedure:
1) Fix the furnished hanger metal 7 with two screws 8 .
(4 locations in total)
2) Using an insert-hole-in-anchor, hang the hanging bolt.
3) Install a hexagon nut and a flat washer (field supply) to
the hanging bolt as shown in the figure in the below,
and lift the unit to hang on the hanger metal. Ceiling side
4) After checking with a level that the unit is level, tighten
the hexagon nut.
* The tilt of the unit should be within ±5° in front/ back
and left/right.
Hanging bolt (M10 or M8)
Six-sided nut (M10 or M8)
15~20

Flat washer
Nut

Flat washer
Hanger metal 7
Hanging bolt BP unit

3. Wall-mounted type Screws 8


Hanger metal 7
Procedure:
1) Fix the furnished hanger metal 7 with two screws 8 .
(4 locations in total)
2) Create a gap with the wall and screw in the temporary
screws, and hang the BP unit. Screws 8
3) After checking with a level that the unit is level, fix the
Hanger
unit with screws (M5, field supply). metal 7
* The tilt of the unit should be within ±5° in front/ back
and left/right.
Screws (M5)
(field supply)

CAUTION
• Be sure to install the unit with the top surface up. Temporary screw:
Screw in temporarily after
• Do not install near bedrooms. The sound of refrigerant opening a slight gap with
flowing through the piping may sometimes be audible. the wall.

Temporary screws:
attach and then hang the Screws (M5)
unit on them. (2 screws) (field supply)

: screw for fixing. (4 places)

8 „English

3P155399-1E

16
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 9 Monday, March 7, 2011 10:30 AM

Connection of Refrigerant Piping


See the indoor and outdoor units installation manual for details on the size of connection piping to the indoor and outdoor units.

1. About brazing pipes on site


1) Before brazing, remove the heat insulation.
2) Remove the blue-colored tape, and throw it out.

Heat
insulation 10

3) Wrap the pipes to be brazed with sufficient wet cloths so that brazing
does not affect the unit.
Wet cloth
4) After brazing, use wet cloths or spray mist to sufficiently cool off all
pipes.
brazing
5) When brazing, be careful that the flame of the torch does not come in
contact with the unit.
(Since the inside of the unit is made of plastic, it may become
deformed or melt, destroying its heat-insulation performance.)

Wet cloth

2. Insulation of pipes
1) Attach heat insulation to each pipe. One-sided adhesive tape
(field supply)
2) When attaching insulation to the pipes, use one-sided adhesive tape or
similar materials to thoroughly prevent air from entering the heat
Heat insulation
insulation. (field supply)
3) Eliminate any gaps in the heat insulation.

Heat insulation 10

3. Unconnected pipes
Wet cloth
1) For pipes not yet connected to a room, pinch the end of the pipe and
braze them. brazing
2) When brazing this area too, wrap the pipes with sufficient wet cloths to
protect the unit.
3) After brazing this area too, cool the pipes sufficiently.

Wet cloth

brazing
4) Attach heat insulation, and use one-sided adhesive tape to thoroughly
prevent air from entering the heat insulation.
One-sided adhesive tape
5) Cover the ends of the pipes with sufficient heat insulation. (field supply)

Heat insulation
(field supply)

„English 9

3P155399-1E

17
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 10 Monday, March 7, 2011 10:30 AM

Connection of Refrigerant Piping


• After brazing and system leakage check, connect a
Heat insulation Heat insulation
heat insulation (field supply), and let it cure
(field supply) (field supply)
completely following the procedure illustrated right.
Use the heat insulation with the following Clasp Heat insulation 10 Clasp
specifications: (field supply) (field supply)
Thermal conductivity: 0.041-0.052W/mK (0.035-
0.045kcal/mh°C or more) / thickness 13mm or more BP unit
Heat resistance = 100°C or higher (only heat pump
system)
• To ensure that the weight of the local interunit piping Indoor unit side piping Outdoor unit side piping
does not bear on directly on the BP unit, secure it
near the BP unit using the clasp (field supply).
Place the heat insulation up against the BP unit to
prevent any gaps from forming between the two, and
wrap with masking tape as shown in the figure.

• When connecting indoor units, make sure to connect


Hanger metal 7
refrigerant pipes and connection wires to the appropriate connection ports
marked with matching alphabets (A, B and C). Room A Room B Room C
(Gas) (Gas) (Gas)

Room A Room B Room C


(Liquid) (Liquid) (Liquid)
〈View from the indoor unit〉
• When changing the routing direction, use the pipe joints 2 and 6 (accessories).
Use pipe joints 3 , 4 and 5 to connect refrigerant pipes with different diameters.
Indoor unit side (Gas) Outdoor unit side (Gas)
Piping
Brazing (field supply)
Cut line for I.D φ12.7 Pipe joint 2
I.D φ9.5
Pipe joint 6 Cut line for Cut line for
110
125

Cut line for straight I.D φ12.7 I.D φ15.9


70

125

Pipe joint 6
Brazing Piping
Piping Piping Pipe joint 3 (field supply)
(field supply) Brazing (field supply)
I.D φ9.5 I.D φ12.7
When straight. When the direction is changed.
I.D φ15.9 I.D φ12.7
Brazing Brazing
Connection for φ15.9 piping. Connection for φ12.7 piping.

When straight.
Indoor unit side (Liquid)
45

Pipe joint 5
Cut line Pipe joint 2 Cut line for
Brazing
for O.D φ6.4 I.D φ15.9
Piping
Piping Piping (field supply)
I.D φ9.5
(field supply) (field supply) I.D φ19.1
Pipe joint 3
Connecting φ9.5 I.D φ12.7
45

Brazing Brazing
interunit piping
Cut line for
I.D φ15.9

Outdoor unit side (Liquid) Connection for φ19.1 and φ15.9 piping. Connection for φ12.7 piping.

When the direction is changed.


Pipe joint 4
Piping
(field supply)

Brazing
I.D φ6.4 NOTE
When changing the direction of the piping to
Connecting φ6.4
something other than the above, bend the
interunit piping
piping on site.

10 „English

3P155399-1E

18
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 11 Monday, March 7, 2011 10:30 AM

Connecting the Wiring


The following kind of wiring methods is okay for the power line.

Pattern 1 N2 Pattern 2 N2
L2 BP unit L2 BP unit
N1 3 Power N1 3
L1 voltage L1

N2 N2
L2 BP unit L2 BP unit
N1 2 Power N1 2
L1 voltage L1

N2 N2
L2 BP unit L2 BP unit
Power N1 1 Power N1 1
voltage L1 voltage L1

• Crossover wiring is possible • It is also possible to supply


for the power line. power from the BP units
themselves.
CAUTION
• Be sure to connect the power
line to L1 and N1.
• For crossover wiring, take the
line from L2 and N2 and
connect it to L1 and N1 on the
other BP unit.

Work procedure Electrical equipment


1) Remove the screws and pull off the electrical equipment cover. cover

Screw (M4×12L)

2) Tape is attached to the wire binding band. The purpose of the tape is to prevent small animals from entering the unit.
Only remove the tape from places where wiring it to be passed through.

CAUTION
If the tape is not replaced for
places where wiring will not pass
through, small animals may enter,
causing product malfunction.
4

The tape to
4

prevent the entry


4

of small animals
P

The tape to
prevent The tape to prevent the entry of small animals
the entry of Wire clamp Wire clamp
(tape is attached when unit is shipped to
small animals prevent animals from entering the unit)

„English 11

C: 3P155399-1E

19
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 12 Monday, March 7, 2011 10:30 AM

Connecting the Wiring


3) Follow the instructions on the wiring nameplate to connect the connection wires of indoor/outdoor units to terminal block
numbers. (1, 2, 3, F1 and F2) Always fix each ground wire separately with a ground screw. (See the figure below.)

NOTE: The terminal block numbers are arranged from top to bottom in order of 1, 2 and 3.
Peel the outer coating leaving Binding band 9
10mm from the wire clamp. Example Secure the wires with binding band 9 to Warning
prevent them from coming out if pulled Do not use tapped
10mm 〈For 3 rooms〉 on from the outside.
wires,stand wires,
extensioncords, or
starbust connections,
Wire as they may cause
clamp overtheating, electrical
shock, or fire.

1
2 Room A Transmission wire (To other BP unit: F1, F2)
3
4

Transmission wire (To other BP unit: F1, F2 or to


1 outdoor unit: F1, F2) sheathed two-core cables
F2
2 Room B of 0.75mm² to 1.25mm²
4

F1 Wire clamp
3
For other BP unit (To L1, N1)

4
1 N2
P

2 Room C L2 CAUTION
N1
4
3 Mistakenly connecting the power
L1
supply to this terminal block could
cause control operating malfunctions.

Connection wire for Power supply wire


indoor units. Ground for indoor units.
H05VV(*), 4 wires *Fix each wire H05VV(*), 3 wires
1.6mm or 2.0mm separately. 1.6mm or 2.0mm Power supply
Safety Earth leakage
When wire length exceed 1~50Hz 220-240V
breaker 15A circuit breaker
10m, use 2.0mm wires. 1~60Hz 220-230V

(*) Only in protected pipes, use H07RN-F when protected pipes are not use.
Specifications for local wiring power cord and branch wiring are in compliance with IEC60245.

CAUTION
• All local interunit wiring must be secured using the wire
binding band over the insulation, as shown in the figure. Insulation

• When connecting the connection wires to the terminal


block using a single core wire, be sure to perform curling.
Problems with the work may cause heat and fires.
Wire binding band

• Use shield wire (Transmission wire only).


Screw Cable clamp (copper foil is provided.)

Fix the shield area of the unit to unit wiring


to the copper foil area of the clamp.
Shield control wiring between units

12 „English

3P155399-1E

20
BPMKS967A3 / BPMKS967A2 EDFMT391758

01_EN_3P155399-1E.fm Page 13 Monday, March 7, 2011 10:30 AM

4) Allow 300mm for the pulling-out section of harness.

+300mm
of slack

+300mm
of slack

5) Return the electrical equipment cover to its original position, and fix it with the
screws.

Screw
(M4×12L)
Install the electrical
equipment cover.

Operating Test
Follow the “Operating test” as described in the installation manual of the outdoor unit.
If the BP unit does not operate normally during the test run, the error can be checked on the remote controller display for the indoor
unit.

Error codes displayed on the remote controller


Malfunction code Nonconformity during installation Remedial action
Electric expansion valve connector not
A9
connected (BP unit)
Printed circuit board faulty
E2 Please contact your dealer.
(BP unit)
Liquid and gas thermistor faulty
J0
(BP unit)
Transmission error between BP unit Connect correctly the interconnections between BP unit and
U4
and indoor unit indoor unit.
Transmission error between outdoor Connect correctly the interconnections between outdoor and
U9
unit and other BP unit other BP unit.
Transmission error between outdoor Connect correctly the interconnections between outdoor and
UJ unit and this BP unit connecting with the this BP unit connecting with the indoor unit of error code
indoor unit of error code displayed displayed.

The BP Unit
Simple diagnosis can be done using the LEDs on the BP unit’s circuit board.
For details, see the label on the inside of the BP unit’s electrical equipment cover.

„English 13

3P155399-1E

21
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

VRV is a trade mark of Daikin Industries, Ltd.


VRV Air Conditioning System is the world’s first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.
VRV is the trade mark of Daikin Industries, Ltd., which is derived from the technology we call “variable refrigerant volume.”

●Specifications, designs and other content appearing in this brochure are current as of October 2017 but subject to change without notice.

©All rights reserved 10/17 FS

You might also like