TABLE 4-2 MINIMUM HANGER SIZES FOR ROUND DUCT Maximum Wire Dia, Spacing Dia Rod Strap Tan 2 One aga ry Txaaga 250 mm dn 37m (one 2.75 mm 6.4mm 25.4x0.65mm tte 2 Two 1298 wa 1229 or One ga 460 mm 37m One 4.27 mm 6.4mm 25.40.85 mm 19-24 12 Two 1092. wa 12298 siomm 31m ‘Two 2.51 mm 6.4mm 25.40.85 mm 25-8 2 Two 8 ga 308 12098 900 mm 31m Two 2.7 mm 9.5mm 28.41.00 mm 37-50" 2 Two 38 Two 1" 20 ga. s27omm 37m Two8.5 mm (2) 28.4» 1.0mm 51-60" 2 > _ wore Two 1"x 18 9a 1520 mm 37m Two 3.6mm (2/284 1.31mm 61-8 2 ———~ wos Two 1"x 16 9a 2130 mm 3.7m Two 8.5 mm (2) 28.41.61 mm NOTE: 1. Straps are galvanized sted: rods are un- are to be installed, adjust hanger izes to be Coated or galvanized sted: wire is black ane Nrealed, bright basic, or galvanized, All are alternatives. 2. SeaFig. 4-4 for lower support 3. SeoFigs 4 2and4. Stor upper attachments. 4, Table allows for conventional wall thick- 48 ness, and joint systems plus one lb’st (4.89 kg/m?) insulation weight. If heavier ducts HVAC Duct Construction Standards Metal and Flexibl within their load limits: soe allowable loads with Table 4- 1, Hanger spacing may be ace justed by special analysis. Designers: For industrial grade supports, in- cluding saddles. single load trapeze lads, longer pans and flange joint loads, see SMACNA's Round Industrial Duct, Construction Standards. SeoFigs 3- 9 and3- 10 for flexible duct sup- ports. + Second Edition SMBEN STRAP HANGERS HANGER, STRAPS NOE TRAPEZE HANGERS STRAP OR oD, 50" MAX. UNLESS FOOT (1324"mm) OF STRAP. 15 PLACED UNDER A BOTTOM Sores iL, SCREWS MAY BE 1 aN. oMTTeD iF Hadoes Loops (25 mm) r Loko RATED SIZE BOLT(S) FOR ashe AS We iF i 5 secure WIRE 10" (254 mm) DIA. MAX < @AND OF SAME Size 24 (610 rm) ae ano SAP Ae Mas 36” (914 mm) Da, Wa HANGERS MUST NOT DEFORM DUCT SHAPE iA ANGER RODS, WIRES ' aa ws /Zneees ALTERNATE LOCATION (VERIFY UPPER TaAoece LORD ceacrsy REINFORCEMENT MAY BE USED FOR ATTACHMENT IF IT QUALIFIES FOR BOTH DUTIES. DO NOT EXCEED ALLOWABLE LOAD LIMITS, BAND ONE HALF-ROUND MAY BE USED IF DUCT SHAPE IS NAINTAINED. FIGURE 4-4 LOWER HANGER ATTACHMENTS SMAGNA, HVAC Duct Construction Standards Metal and Flexible « Second Ed 49 STRAP HANGERS: j ORAS th { \ J sy ‘SIZE BAND PER TABLE BELOW, BUT INNO EVENT LIGHTER THAN ‘SELECTED HANGER STRAP, 180° SUPPORT BAND STANDARD ‘360° SUPPORT BAND OPTIONAL. - S =} fa} G 2 6 4 < = wor Lb FIGURE 13-4a SUPPORT TYPE 1 SIZE BAND PER TABLE BELOW. BUT eae INNO EVENT LIGHTER THAN, SeLecreDHaNGen'straP \ | {~ 50 i (— \ —A\ 0) wer ¢ ) le —_, FIGURE 19-40 SUPPORT TYPE 2 ij 4 {__ S) |) sour \\ VY 0 ‘ ) } Y a, . ez ros eugpenone 7 FIGURE 18-40 OR.COMPANION SUPPORT TYPE NOTE: TO SELECT HANGER RODS AND STRAPS, SEE TABLES 13-9, 13-9M, 13-10, 13-10M, 13-11, AND 13-11M FOR HANGER CAPACITIES. FIGURE 13-4 METHODS FOR HANGING ROUND INDUSTRIAL DUCT suena 18.6 Round Industrial Duct Construction Standards + Second Edition SIZE BAND PER TABLE ON FIGURE "8-4. BUT INNO. EVENTLIGHTER THAN. SELECTED HANGER STRAP’ ‘ — { \ 0 ' Ui tty) 4 » mvon second IN CLOSE PROXIMITY TO STIFFENER RING 15> TABLE RATING 6" (150 mm) MAXIMUM HANGER BAR FLANGED. sonny a | “A | + SUPPORT TYPE 4 135 TABLE RATING () Y ANGLEFINGS | SUPPORT TYPES 1 SPPRLE RAT 7 MANGER ROD (— tay ) \ Y ~) U a ) } ee @y ANGLE RINGS: SUPPORT TYPES 2» TABLE RATING _ —— (— la () VU ) { Zvananaunasa00ce nate tes" support TPES wit ATTACHED RINGS TABLE RATING NoTES 1, FOR WELDING OF REINFORCEMENTS SEE FIGURE 12-1 AND FIGURES 12-4 THROUGH 12-7 WELDING OF DUCT CONNECTIONS. 2. TABLE RATINGS REFER TO TABLES 13-1 THROUGH 13-3 (TABLES 13-1M THROUGH 13-3M). 3. EQUALLY SIZED FLAT RINGS MAY BE SUBSTITUTED FOR ANGLE RINGS. FIGURE 13-5 SUPPORT SCHEMES WITH EXTENDED RATINGS queen QMAENA) Round Industrial Duct Construction Standards » Second Edition 13.7 o zg im S © a =} a rd ° =} Ey a & = « I Ey 2 a a = = FOR CHANNEL LOAD CAPACITIES: ‘SEE TABLE 13-4 AN ean kk \/\| | | Bou“ Ml weioep / \II Sabotreo {4 FRAME / \ | i I Th Ef | wT i in ZA UNS EPEAT BRACING FOR TALLER APPLICATIONS. — FIGURE 13-9 FIGURE 13-9 ROUND INDUSTRIAL DUCT SUPPORT METHODS Round Industrial Duct Construction Standards + Second Edition wein 2 pLAcES>—y—2 ats Ware? 7. Steve tee. \ <> FIGURE 13-94 (Cc a SCH.40 PIPE tess _ goleo ) -— WeBED TO | HEEL ear ve OF ELBOW FIGURE 13-8 FOR ANGLE LOAD Pw (CAPACITIES ae SEE TABLE 13-5 oe 5 Ue fyeies we1peD 70 stk AO eRERNEDS BSN Ne FIGURE 13-94 13.19 kb ir S - a Py rc) Fa my Fd z= 3 a a fo} = z= 7 F == = (2285 mm) a — ‘SEE NOTE BELOW, FRAMING CHANNEL —~ |+— VARIES, SEE PLAN _— (€) WFBEAM, (@wreeam — [sees | 3 7 L I = 3 a a 3 - Pret ade co5 nnn ra /- SS-9MFOR Sizes ane ose x | ouct ii | SEEFIGURE 13-4 FOR _/- SoPPORT BAND SIEBS — it 4+-— WA | Ir a i 4mm) MAX: GAP DUCT HANGER DETAIL, NOTE: THERE ARE NUMEROUS METHODS OF OVERHEAD SUPPORT ATTACHMENTS AVAILABLE. THE CAPACITY OF THESE SYSTEMS ARE SHOWN IN TABLES 13-4 THROUGH 13-7. FIGURE 13-13 DUCT HANGER DETAIL rey Round Industrial Duct Construction Standards + Second Edition 13.23

You might also like