1. Reactor dimensions for 6.4 KL capacity is as per GMM catalogue.
2. We have designed for worst case scenario i.e. with the low boiling point solvent (MDC BP-39.5 ⁰C). 3. Occupancy considered is 70% constant. As distillation will be progressed, occupancy goes down and area required will be also less. 4. General thumb rule for (primary Condenser = reactor jacket area X 1.5) and (secondary condenser = 0.3 X Primary condenser) 5. Following calculation is for worst case scenario and requirement will be 75 % of area in case of water.
Condenser Area Required for low BP solvent (MDC)
Reactor Capacity 6400 ltr Remarks Total HT 18.02 m2 Calculated from GMM Faudler % Occupancy 70% Effective HT 12.614 m2 Calculated Steam Pressure at 2 kg/cm2 reactor Saturated steam 120 C from steam table temp Solvent Selected MDC Specific Heat; Cp 0.28 Kcal/Kg.k Latent Heat 79.11 Kcal/Kg t1 25 C t2 45 C LMTD-1 84.61 C kcal/ Overall U 250 Considered for MSGL reactor m2.hr.K Q(boilup) 266806.2 kcal Boilup 3372.598 kg Sensible Heat 5665.965 Latent Heat 266806.2 Total Heat 272472.2 kcal kcal/ Overall U Condenser 400 m2.hr.K Inlet Utility 15 C Outlet Utility 22 C LMTD-2 21.11 C