THE RMF OFF-LINE UNITS ATTACK CONTAMINATION OF YOUR SYSTEM AT THE SOURCE. IN ADDITION TO SOLID PARTICLES,
THESE FILTERS ARE ALSO CAPABLE OF REMOVING WATER FROM THE OIL. THE USE OF RMF FILTERS MEANS LESS DEFECTS,
LESS MAINTENANCE, AND LESS WEAR AND TEAR OF THE HYDRAULIC COMPONENTS. THE RMF OFF-LINE UNITS CAN BE
FITTED TO EVERY IMAGINABLE INDUSTRIAL APPLICATION WHERE HYDRAULIC OR LUBRICATION SYSTEMS ARE PRESENT.
The RMF Systems radial micro filter units are filtering the oil is returned to the tank.
characterized by their extremely efficient Off-Line Units can continue to work even THE BENEFITS OF RMF FILTERS
filter elements with a fineness of down to when the main system is not in use. Element ►►Reduced cost of ownership
0,5 micron. If required, different micron sizes change can also be done without interfering ►►Extremely clean oil due to high
are available to suit any application. with the main system. filtration efficiency
The RMF Off-Line Units are specially ►►Prevention of channel forming
designed for industrial hydraulic YOUR BENEFITS by radial filtration direction
installations. The hydraulic market accepts that 80% ►►Large dirt holding capacity
The Off-Line Units are available in single or of mechanical failures are caused by ►►Large water holding capacity
multiple housing configurations. contamination in the system. ►►Compact and easy maintenance
design
OPERATION The RMF Off-Line Units attack this ►►Longer usage life for oil and
The Off-Line Units can be easily mounted to contamination at source and are also components
new and existing hydraulic installations. By capable of removing water from the oil. This
means of an integrated pump-motor unit in prevents the catalytic reaction of water and APPLICATION
the Off-Line Units, the oil is pumped from solid particle contamination, resulting in ►►Steel industry
the reservoir through the filter unit. After extended usable oil life. ►►Plastic injection moulding
►►Power generation
►►Marine Industry
►►Pulp & Paper Industry
►►Cement Industry
►►Flight Simulators
PRODUCT DETAILS
OLU1A OLU1B
Nominal Flow 2,1 l/min 4,2 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 3
⁄8’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ±1,350 l ± 2,700 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 14 kg 18 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
170
±189
324
190
170
±189
4xØ8,5 4xØ8,5
734
120
160
120
428
169
177
PRODUCT DETAILS
OLU2A OLU2B
Nominal Flow 4,2 l/min 8,4 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 2,700 l ± 5,400 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 21 kg 30 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
4xØ8,5
720
4xØ8,5
120
120
160
428
197
177
163
PRODUCT DETAILS
OLU4A OLU4B
Nominal Flow 8.4 l/min 16,3 l/min
Standard Max. Oil Temperature1 80° C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female 3
⁄4’’ BSP female
Outlet connection EW 22L
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 5,400 l ± 10,800 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 39 kg 61 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
494
494
345
335
820
523
OLU
PRODUCT DETAILS
OLUW1A OLUW1B
Nominal Flow 2,1 l/min 4,2 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection3 3
⁄8’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
Max. Water Absorption capacity 850 ml (with 30A5 element) 1,2 l (with 60a5 element)
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ±1,350 l ± 2,700 l
Fluid Compatibility4 Hydraulic fluids according ISO 2943
Approximate weight 18 kg 22 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
313
4xØ8,5 4xØ8,5
706
120
160
120
160
401
149
149
PRODUCT DETAILS
OLUW2A OLUW2B
Nominal Flow 4,2 l/min 8,4 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
Max. Water Absorption capacity 1,2 l (with 30A5 element) 1,9 l (with 60A5 element)
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 2,700 l ± 5,400 l
Fluid Compatibility4 Hydraulic fluids according ISO 2943
Approximate weight 25 kg 34 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
340
320
313
4xØ8,5
706
120
120
160
160
401
PRODUCT DETAILS
OLUW4A OLUW4B
Nominal Flow 8,4 l/min 16,8 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female ¾’’ BSP female
Outlet connection 22 L
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
Max. Water Absorption capacity 2.4 l (with 30A5 element) 3.8 l (with 60A5 element)
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 5,400 l ± 10,800 l
Fluid Compatibility4 Hydraulic fluids according ISO 2943
Approximate weight 43 kg 65 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
494
521
339
341
540
828
OUTLET 22L
INLET 3/4"-BSP
OLUW
PRODUCT DETAILS
OLUH1A OLUH1B OLUH1B
Approx. 2,9 l/min with 2kW heater
Nominal Flow
Consult RMF Systems for 4kW heater and flows exceeding 2,9 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 3
⁄8’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Heater Capacity 2 kW 2 kW 4 kW
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 30HB, 30HV, 30NB, 30NV, 60HB 60HV, 60NB, 60NV,
Suitable elements 3
30G1B, 30G1V, 30G3B, 30G1B, 30G1V, 30G3B, 30G3V, 30A5B, 60G1B, 60G1V,
30G3V, 30A5B 60G3B, 60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 1,350 l ± 2,700 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 24 kg 28 kg 30 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
340
320
188
4xØ8,5
4xØ8,5
869
567
160
160
120
120
OLUH
THE BENEFITS
►►Extremely clean oil due to high ►►Prevention of channel forming by ►►Compact and easy-maintenance
filtration efficiency radial filtration direction design
►►Permanent reporting of contamination ►►Increased flow capacity ►►Environmentally friendly elements
levels ►►Large dirt holding capacity available
►►Permanent reporting of moisture ►►Large water holding capacity ►►Longer life for oil and components
RH % and temperature ►►Reduces cost of ownership
PRODUCT DETAILS
OLUS1A OLUS1B
Nominal Flow 2,1 l/min 4,2 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 3
⁄8’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ±1,350 l ± 2,700 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 16 kg 20 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
224
4xØ8,5
160
120
425
173
738
PRODUCT DETAILS
OLUS2A OLUS2B
Nominal Flow 4,2 l/min 8,4 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female 1
⁄2’’ BSP female
Outlet connection 1
⁄2’’ BSP female
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ±2,700 l ± 5,400 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 22 kg 32 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
341
313
4xØ8,5
461
160
120
401
4xØ8,5
746
120
160
OUTLET 1/2”-BSP INLET 1/2"-BSP
PRODUCT DETAILS
OLUS4A OLUS4B
Nominal Flow 8,4 l/min 16,3 l/min
Standard Max. Oil Temperature1 80°C
Max. pressure filter housing 20 bar
Inlet connection2 1
⁄2’’ BSP female 3
⁄4’’ BSP female
Outlet connection EW 22L
Power supply Electric Motor Various electrical power supplies possible (see ordering code)
30HB, 30HV, 30NB, 30NV, 60HB 60HV,
30HB, 30HV, 30NB, 30NV, 30G1B, 30G1V, 60NB, 60NV, 30G1B, 30G1V, 30G3B,
Suitable elements3
30G3B, 30G3V, 30A5B 30G3V, 30A5B, 60G1B, 60G1V, 60G3B,
60G3V
By-pass openings pressure 6,2 bar (at 0 bar back pressure)
Pump safety valve 15 bar
Max. Tank volume ± 5,400 l ± 10,800 l
Fluid Compatibility 4
Hydraulic fluids according ISO 2943
Approximate weight 39 kg 61 kg
For other oil temperatures please contact RMF Systems
1
Inlet Connections are pump dependent. Please contact RMF Systems or your distributor.
2
For complete specifications of the RMF Systems Filter elements see page 41
3
296
504
494
501
669
808
503
OUTLET 22L
INLET 1/2"-BSP
OUTLET 22L
INLET 3/4"-BSP
OLUS 0
TECHNICAL NOTE
E-MOTOR 0.18 kW 0.29 kW 0.37 kW 0.60 kW
50 HZ (3-PHASE) 3.2 cc/rev. 5.0 cc/rev. 5.8 cc/rev. 12.0 cc/rev.
60 HZ (3-PHASE) 2.5 cc/rev. 3.15 cc/rev. 5.0 cc/rev. 10.0 cc/rev.
TABLE 11 - DRIPTRAY
No Driptray 0
Driptray D
=185=
181
177
305
252
202
202
50
170 49
210 86
253
OLU2
296
=298=
294
286
300
294
133 286
93 234
252
202
50
284
296
292
490
4
292
262
284
4
125
252
36
3 2
50
494
=40=
=40=
R8 15 R8
15 3
50
50
125
11
11
R18
250
250
MARKET LEADING
The Oil Quality Sensor (OQS) is 60 times
more sensitive to oil degradation than
any other dielectric constant measuring
sensor.
THE RMF SYSTEMS GEAR PUMPS ARE EQUIPPED WITH A PRESSURE RELIEF VALVE ON THE SUCTION SIDE OF THE PUMP. THE
SAFETY OF THE PRESSURE RELIEF VALVE IS SET TO 15 BAR.
TECHNICAL NOTE
E-MOTOR 0.18 KW 0.29 KW 0.37 KW 0.60 KW
50 HZ (3-PHASE) 3.2 cc/rev. 4,8 cc/rev. 5.8 cc/rev. 12.0 cc/rev.
60 HZ (3-PHASE) 2.7 cc/rev. 3,2 cc/rev. 4,8 cc/rev. 10.0 cc/rev.