GENERAL STAFF QUALITATIVE REQUIREMENT FOR X RAY SYSTEM

1. INTRODUCTION
A X Ray system is used for “On Site” examination of suspected objects without
applying hand/remote entry technique. The X Ray imagers provide a real time
viewing of the underlying mechanism, allowing the technician to have more
information of the IED and taking better decision for applying the RSP. The X Ray
device can detect contents of closed/concealed object without disturbing it.The
detector must possess the ability to give an account of contents inside a suspected
metal/plastic cased object and the capability to penetrate adequate thickness.

2. AIM

To lay down General Staff Qualitative Requirement for X Ray Equipment.

3. PRESENT SERVICE EMPLOYMENT


A X Ray system is presently employed by trained personall of Corps of Engineers
(and other arms) to detect presence of potential IEDs in concealed casings.

4. QUALITATIVE REQUIREMENTS
a. X-Ray Source
(i) The X–Ray source should be a single package, having robust design with
integrated carrying
handle for one hand portability. The operational wt including bty pack
should not exceed 06
Kgs.
(ii) It should penetrate upto min 25mm of steel.
(iii) It should be capable of being operated at min 3 mtrs from imager both
wired and wirelessly.
(iv) It should provide min 160KVP energy.
(v) It should not contain any radioactive material.
(vi) It should function on pulse or constant potential output.
(vii) It should have rechargeable bty pack which can perform for min 01hr of
continuous operation. Also, one spare bty pack to be provided.
(viii) It should have facility to set the number of pulse or exposure time
manually and through CDU (Control and Display Unit), depending on the
type of object.
(ix) It should have a safety interlock key with visual and audible indicators to
warn the operator when activated.
(x) It should not have any warm-up time.
(xi) It should have backlit LCD for night operations.
(xii) It should be provided with charger (OEM std only) for charging the
rechargeable bty packs.
(xiii) It should be provided with standard camera tripod to mount, stabilize
and elevate x-ray generator.

b. Imager Panel and Interface Control Unit / Box


(i) The imager should have min imaging area of 16.5” (W) x 13.5” (H) with
min dead space at bottom and on any one side (max 10mm allowed) from external
dimensions.

(ii) The thickness of the imager should not exceed 24mm.

(iii) It should have a dynamic range of min 14bit and resolution min 3.5
lp/mm with pixel pitch of min 135 microns for clear and sharp images.

(iv) Both combined should not weigh more than 06kgs along with its
attachments (support/legs).

(v) The imager should have capability to operate in both wired (min 50mtrs)
and wireless (min 150 mtrs) mode from Control and Display Unit. Additional
100mtrs wire with spool to be provided separately for extension of wired
mode.

(vi) The interface control unit/Box should have capability to operate in both
wired (min 3 mtrs) and wireless (min 10 mtrs) mode from both X-Ray source
and imager.

(vii) The imager panel and Interface Control Box /Unit should be battery
operated and should have bty operation duration of min 05 hrs.

(viii) It should provide instant imaging of the object with not more than 5
seconds image acquisition time in both wired and wireless mode.

(ix) Imager should be provided with such a support / legs which enables it to
be easily positioned on uneven surfaces or slope.

(x) Imager and ICU should have a visual bty low level indicator.

(xi) It should also be provided with a tripod (of similar height that of the x-
ray generator) which should be equipped to hold the imager for easier
positioning at different heights from ground level.

c . Control and Display Unit

(i) It should have fully rugged, lightweight, wireless laptop with an option to
convert into tablet PC with one quick swivel.

(ii) It should have the following minimum configuration or better CPU -

(aa) Intel core i5 -3610 ME v Pro Processor

(ab) 2.7GHZ with Turbo boost up to 3.3GHZ.

(ac) 3MB Cache.

(iii) Storage and memory :

(aa) 4GB-16GB SD RAM (DDR3L-1333MHZ)

(ab) Stock-mounted flex-connect hard drive with quick -release.

(ac) 500GB or more and 7200 rpm Hard drive.


(iv) Display: 10.1” or more XGA Sunlight -viewable (LED) 1024x786 or better.

d. Soft ware Features

(i) A user friendly menu driven advanced software should be provided to


facilitate the operator to choose a wide range of functions.

(ii) It should provide image enhancement and analysis tools as under-

(aa) Pseudo Colouring facility.

(ab) Brightness & Contrast control, smoothing and sharpening of images.

(ac) Stitching and cropping of images.

(ad) Histogram Equalisation and Annotate images.

(ae) Embossing (3D Effect) of the image.

(af) Rotation to 360 degree, Pan, Zoom (Whole image or region of interest)
and Polarity.

(ag) Visual Database of images incl name, date, category, place, fill name
etc.

(ah) Summing and Overlay of multiple images.

(aj) X-Ray Generator Selection, pulse setting, pulse activation.

(ak) On Screen measurement facilities in multiple units.

(al) The X-Ray source should be provided with a system which can
differentiate between organic and inorganic materials.

e. Miscellaneous

(i) The complete system including X-Ray source, Imager unit (including
Interface Control Box /Unit), Control and Display unit alongwith wire. (min
50 mtr) and wireless systems should fit into a ruggedized min two wheeled
transport case and it should not weigh more than 30kgs. Also, the other
accessories should fit into separate ruggedized transport case.

(ii) The RTVS should be provided with mountings to use it via ROV/ Mini
ROV.

(iii) The RTVS should be able to operate in temp range of -100C to 500C.

(iv) Technical literature and users handbook for both hardware and software
to be provided.

(v) It should have a provision of a slider to manoeuvre the


imager-Resistive/capacitive touch screen.

(vi) Key board and input:

(aa)Touch screen or multi touch + digitizer.

(ab) Integrated stylus holder.


(ac) Power Supply : AC adaptor: AC 100V-240V 50/60HZ.

(ad) Bty op: 05 hrs(Touchscreen) and 05hrs (Multitouch + digitizer)