You are on page 1of 2
SY 2 rorormmed AL Radiograph interpretation, as third party Inspector/ client representative. 1.0 Carefully study the following documents; © Latest Purchase Order, * Approved Drawing ( Design code, Acceptance Code, ,Extent of RT, Stage of RT)” © Approved QAP ( Quality‘Inspection Plan)/ ITP (Inspection Test plan) - (Acceptance Code, . Code of RT Technique, Extent of RT& Stage of RT) Applicable & approved RT procedure, Validity of “Qualification Certificate” of RT Level II personnel. (Along with Valid Eye Test Certificate). 2.0 If possible, physically verify the job for verifying; © Completion of all previous stages and availability of Inspecting reports, as per approved QAP/ ITP, duly signed by the Quality personnel. Surface finish, weld reinforcement, job identification/punching as per approved RT procedure. 3 Study the “RT Technique Sheet” as per applicable & approved RT procedure 4 Study the “Radiograph interpretation/ | Evaluation Report” far __“completé coverage of Radiography as per QAP/ITP.(quantity/ segment length, weld length/-citcumfererice- as per the drawing, identification of Radiograph as marked in Report and.on wrapper, compliance of RT procedure requirements for Radiograph Density, JQ selection, placement., Sensitivity required/ obtained, signed by Certified RT Level Il personnel 5. Compare the identification of Radiographs with as marked on wrappers. 6. Check the Densitometer for proper functioning and validity of calibration. 7. Reduce the room light, as per requirement, and adjust Eyes at least for 5 minutes. - . 8.~Check and interpret at each Radiograph one by one for; © PyeSenk a “B Lekker . RADIOGRAPHIC DENSITY LIMITATIONS: © The transmitted film density through the radiographic image of the body of the appropriate hole !Of or adjacent to the designated wire of a wire IQ! and the area of interest shall be; © Minimum 1.8 for radiographs made with X-ray source and the maximum density shall be 4.0, %fay. = Vo ae he © Minimum 2.0 for radiographs made with a gamma ray source, and the maximum density shall be 4.0. gatmwa-Way = aoe ato « DENSITY VARIATIONS: = If density of radiographs anywhere through the area of interest, varies by more than — 15% to +30% from the density through the body of the hole type IQI or adjacent to the designated wire of wire type IQI, within the minimum/maximum allowable density range specified, then an additional IQI shall be used for each exceptional area / areas and the radiographs shall be taken again. Sensitivity should beas per.Table T276.°- © Discontinuity nature:and size shall be as specified in UW-51/ UW-52. 9.0 Put your remarks and sign the Report, with name and date. Pineal

You might also like