You are on page 1of 4

SGT-400 Industrial Gas Turbine

Mechanical Drive: (ISO) 13.40 MW (18,000 bhp)

The ideal choice for a wide variety of mechanical drive applications, the SGT-400
combines very high efficiency (nominal 36.2 %) with excellent emissions performance
in a rugged industrial design.

The Siemens twin-shaft industrial gas Compressor applications


turbine SGT-400 features a compact Gas injection, gas processing and
gas generator and a two-stage power refrigeration projects utilizing Siemens
turbine, incorporating the latest aero- bespoke centrifugal compressors
dynamic and combustion technologies. (or other proprietary manufacturer’s
The turbine has a simple-cycle shaft compressors)
efficiency of 36.2 %.
Gas boost and gas transmission
The mechanical drive package is very projects utilizing Siemens standard
compact, providing a small footprint and pre-engineered centrifugal pipeline
a high power-to-weight ratio. The twin- compressors
shaft configuration provides excellent
speed and load turndown characteristics Pump applications
to allow maximum flexibility of operation. Utilizing proprietary manufacturer’s
With its reliable, proven gas turbine tech- driven unit pumps of Siemens or client
nology, the SGT-400 offers cost-effective choice, ideally suited to water injection
power for mechanical drive applications. and fluid transmission projects

Industrial Gas Turbines

Answers for energy.


SGT-400 Industrial
Gas Turbine

SGT-400 core engine test facility.

Technical specifications Gas turbine


Overview Mechanical drive Key features
• Twin-shaft, industrial • Direct drive of compressors High simple-cycle and cogeneration
• Mechanical drive: 13.40 MW • Gearbox options are available for efficiencies, cutting fuel costs
• Shaft efficiency: 36.2 % other mechanical drive applications Dual-fuel Dry Low Emissions (DLE)
• Heat rate: 9,943 kJ/kWh combustion system as standard,
(7,028 Btu/bhph) Package meeting stringent legislation
• Full load power turbine speed: • Fabricated steel underbase Twin-shaft arrangement for both
8,000 – 10,000 rpm - Integral oil tank power generation and mechanical
- Multi-point mounting drive, allowing commonality of
• Compressor pressure ratio: 16.8:1
- Optional 3-point mounting parts in mixed duty installations
• Exhaust gas flow: 39.4 kg/s (86.8 lb/s)
• Modular fluid systems incorporating:
• Exhaust temperature: 555° C (1,031° F) Maintenance
- Lubricating oil system
• Typical emissions: NO x: < 15 ppmV - Auxiliary gearbox-driven main pump Site maintainability or optional rapid
and CO: < 10 ppmV (corrected to - AC motor-driven auxiliary pump core exchange as required by customer
15 % O2 dry) - DC motor-driven emergency pump Designed for maintenance:
• Medium-calorific value fuels capability - Horizontally split compressor casing
• Oil cooler and oil heater
(> 25 MJ/Nm3 Wobbe index) - Horizontally and vertically split
• Electrically driven hydraulic
inlet casing
Axial compressor start system
- Combustion chambers, flame
• 11-stage with variable inlet • Hydrocarbon drains tank on package tubes and ignitors easily accessible
guide vanes • Control system for inspection
• Air flow: (ISO) 38.9 kg/s - Siemens SIMATIC PLC-based with - Large side-doors on enclosure for
distributed control and processing equipment change-out
• Nominal speed: 14,100 rpm
capability installed on package - Gas generator and power turbine
- Optional Allen-Bradley system removal on either side of package
Combustion
- Optional off-package systems Multiple boroscope-inspection ports
• 6 reverse-flow cannular combustion • Vibration monitoring system
chambers - BN1701: Standard
• Dry Low Emissions (DLE) system - BN3500: Optional
• High-energy ignitor system • Fire and gas detection equipment
• Fire suppression equipment
Turbine
• On- and off-line compressor
• 2-stage overhung compressor turbine cleaning options available
- Both stages are air-cooled • Combustion air inlet filtration options:
• 2-stage high-efficiency power turbine - Simple static
- Rotor blades have interlocking - Pulse cleaning
shrouds for mechanical integrity - HEPA
• Enclosure
Bearings - Painted carbon steel or
• Tilt-pad radial and thrust stainless steel
• Vibration- and temperature- - Noise level options
monitoring as standard (85dB(A) standard)
SGT-400 compressor package assembly. Two SGT-400 pipeline compressor sets for Sasol Technology (Pty) Ltd,
installed at the Komatipoort compressor station in South Africa.

Package Customer Support


Key features Global support network of Authorized
Short installation time Service Centers
Compact package size, high power-to-weight ratio Emergency service – 24 / 7 specialist
helpdesk
Factory testing:
- Core engine Full field service
- Functional testing of modules as standard Full diagnostic support, remote
- Pre-commissioning of package monitoring
- Optional core customer-witness test OEM modernizations and upgrades
- Optional complete package test In-house or on-site training programs
Minimized customer interfaces Range of maintenance and service
contracts available
Height to top of package: 10.20 m

Height: 3.89 m

7.35 m
length:
e package
Gas turbin
Wid
th : 2.
85
m
SGT-400 – Compressor set

1 Combustion exhaust 4 Enclosure air inlet 7 Core engine


2 Combustion air inlet 5 Fire extinguishant accoustic enclosure
3 Enclosure air outlet 6 On-package controls 8 Driven compressor
SGT-400 Performance

16 16

-5
le
zz
15 9750 15 No
T
0 tP
en
bi
am
w
Lo
14 14 le
zz
No
T

Power output at turbine coupling, MW


Installed Rating 10000 tP
en
bi
(º C )

13.123 MW
15 am
13 13 gh
ure

Hi
er at
emp

10250
le t t

12 12
in e in
Power output at turbine coupling, MW

En g

30
11 10500 11

40
10 10
Nominal power turbine speed

11000

9 9

8 12000 8
-40 -20 0 20 40 60

Engine inlet temperature, º C

7
13000
Power output at turbine coupling
and engine inlet temperature

6 14000

SGT-400 Mechanical drive performance


5
Conditions/assumptions:
16000
Direct drive – no output gearbox. Natural gas fuel.
Sp e c i fi c h e at in p u t , ( k J / k W h)
Altitude: Sea level Ambient pressure: 101.3 kPa
4
5000 6000 7000 8000 9000 10000 Inlet ducting loss: 1.0k Pa* Relative humidity: 60 %
Exhaust ducting loss: 0.75 kPa*
Power turbine speed, rpm

Specific heat input is drawn for an engine inlet temperature of 15° C
Nominal performance but is approximately correct for other temperatures. No CO turndown
Power and specific heat input and speed in operation.

* Duct losses are site-specific according to application.


Please contact your local Siemens representative or
our Customer Support Center for performance quotations.

Published by and copyright © 2009: Siemens Energy, Inc. For more information, please contact Printed on elementary chlorine-free bleached paper.
Siemens AG 10730 Telge Road our Customer Support Center.
All rights reserved. Trademarks mentioned in
Energy Sector Houston, Texas 77095, USA Tel: +49 180 524 70 00
this document are the property of Siemens AG,
Freyeslebenstrasse 1 Fax: +49 180 524 24 71
Siemens Industrial Turbomachinery Ltd its affiliates, or their respective owners.
91058 Erlangen, Germany (Charges depending on provider)
P.O. Box 1, Waterside South
E-mail: support.energy@siemens.com Subject to change without prior notice.
Siemens AG Lincoln LN5 7FD, United Kingdom
The information in this document contains general
Energy Sector Oil & Gas Division
descriptions of the technical options available, which
Oil & Gas Division Order No. E50001-W430-A107-x-4A00
may not apply in all cases. The required technical
Wolfgang-Reuter-Platz Printed in Germany
options should therefore be specified in the contract.
47053 Duisburg, Germany Dispo 34806, c4bs 7447, P WS 12093.

www.siemens.com / energy