You are on page 1of 4
| SANDS” CERTIFICATE ~ ROUTINE TESTS 07" MAR 2019 The following tests were carried out at the premises of Signals & Systems (India) Pvt. Ltd., as ‘i Per specification for ms dos based common meter reading instruments for TAMIL NADU 3 COKE & POWER PVT.LTD, PO NO: TNCPPL/18-19/COKE/POWERI61., PO DATE:31-08-2018, ts It is certified that the 01 No of CMRI bearing the following Serial Number have been tested % and have successfully passed the specified routine tests. S. NO OF CMRI 1903-A3893HSD ‘Thanking you, ‘Yours faithfully, For Signals and Systems (India) Pvt. Ltd Prepared by 7 Paw 4 (Quality Control) 4 i SIGNALS & SYS7IEUS (India) Private Limited 1S0 9001:2015 Certified Company CCIN.NOLUS200TN1997PTCO37EE4 _GSTIN: SZAAACSOGWERIZE PAN: AAACSOGOBR Rogistered Office & Head Office: 15/D-19, rd Main Road, SIPCOT IT Park, Sruser, Chennai, Tarinad ~ 603 103. ee oaa-27470001. 27470003. 27470087. 27470088, Fax: 04427470002, Ema sancstsendsindlacom_ website: wn sandsingia.com. CMRIMAKE : SANDS ROUTINE TEST CMRIS.No — : 1903-A3893HSD. MODEL : CMRI-1010 16.5MB SRAM TEST DESCRIPTION OBSERVATION REMARKS 1. [Pree Fall Test {eight of Fall 1000 MM Visually examined and found no physical ‘Complied with fo. of Falls 2 (Horizontal Position) damage and loss / change of data and condition __Unpacked function 2. Mest of Display of readings Easy readability in varying ambient light | Readable in varying ambient ight ‘Complied with condition. Display has 16 lines and 24 characters per ‘Complied with line on the screen. 3. [fest of Keyboard function fEach English alphabet shall have a Any alphanumeric character is available Complied with: parte key. with sequential operation of single key cedback for Key press acknowledgment user Both tactile and speaker feedback available Complied with 4, [lest of VO Ports (2 Nos.) |The CMRI shall be having two serial Both ports tested for comm Complied with inptloutput ports, one port shall be serial | BCS ort RS232 compatible. Another optional ert can be used for convenience of onnecting peripherals such as bar-code derprineerbatery _chargerloader charger etc. 5, |Test of Power for Optical Probe [the CMRI shall be able to provide power | Pin No. (vce) and pin no.5 (Gnd) of COM ‘Complied with supply for optical sensor used for meter | 1 and Pin No23 (vec) and pin no.12/13, eading applications (Gnd) of COM 2 showed voltage of Sx. Tested with SANDS universal probe, which requires exteral power supply [fest of Memory 6. [The CMRI shall have generally a memory | ‘The CMRI has 16.5 MB SRAM, out of farnsy of 165 MB SRAM wit batery | which 160 MB is uscd fr sofware and ‘Complied with ackup. data, This was verified using the command sz. IOS / OS on FLASH / EEPROM ‘Complied with femory BIOS / OS on Flash Memory Pa 7, fest of Communication with various pe of meters downloading data from: @) LAT METER Readings taken and enclosed Complied with ) L&T DLMS METER (c) Secure Meter 8, fest of Real Time Clock function fa) The clock shall have a minimum of 15 | The CMRI uses battery of 2100mAh . It | Complied with lays battery backup. gives 35 days battery backup. ) The clock shall have a 20 years ‘Complied with valendar The CMRI uses RTC with 100 years calendar 9, |Test of Secure Time Setting Facility (a) The CMRI shall have facility to set The time in CMRI could not be changed Complied with fime from the BCS. Proper security for | — from its keyboard. However, it s possible is shall be ensured. to change time ofthe CMRI using the PC. ) The meter specific MRI programs | Tested witha Test software Complied with iall have the ability to use CMRI time lock to log all ime related events. 10, fest of Battery Charging while immunicating with BCS 1, To reduce the equipment down time | The battery could be charged using 25 pin Complied with inventories, there shall be provision to | DB Connector, without removing the charge the CMRI battery without being battery pack. smoved from the equipment. VA. suitable battery charger for | The CMRI provided with Fast Charger tomatic charging of CMRI battery shall | tested for communication with computer | Complied with provided. Ex. Fast Charger hile on charge 11. [fest for Auto Power Save [there shall be provision for Auto Power | ‘The unit gives audio alarm after 4 minutes | Complied with we which shall force the instrument in} and, on no operation for about one-minute, sleep mode in case of no activity for $ | the CMRI switches off automatically nites s = oe ee ROUTINE TEST ‘Type: HT SI. No.: 00903155 [Make : L&T CMRISILNo. | Parameters | Meter Display | Parameters SANDS CMRI KWh KWh 001355.10 1335.10 1903-43893HSD | KVARh area KVARh 876.88 Type: HT SI. No.: 13404118 Make : L&T (DLMS) CMRISI No. | Parameters | Meter Display | Parameters SANDS CMRI KWh KWh 001517.85 1517.85 1903-A3893HSD | KVAh 1559.45 KVARh 1559.45 Type: HT SI. No.: MSB 10469 [Make : SEMS CMRISLNo, | Parameters] Meter Display SANDS CMRI KWh KWh 96 0000096 1903-A3893HSD | KVARh 0000021 KVARh 2 FS hes Sear: a

You might also like