Professional Documents
Culture Documents
applications.
26.6 (1.05)
Note: Dimensions shown in mm (inches)
CP+T Series
Ceramic Capacitive Pressure Transducer
with Temperature Function
Features and benefits Typical applications
• Pressure and temperature • Air conditioning and refrigeration
WORLD CLASS measurement in one package • Alternative energy management
• Fast in-stream temperature • Compressors and pumps
PERFORMANCE
measurement • Engine controls and monitors
• Precise superheat measurement
The CP+T Series • ECE-R110 (CNG) and ECE-R67 (LPG)
combines a ceramic approved versions
capacitive sensing
element with a fast Technical specifications
and accurate NTC ther- Pressure range Performance (temperature)
0 to 4.5 through 0 to 40 bar abs Accuracy (delta R/R)............±1 %
mistor. This integrated (0 to 65 through 0 to 600 psia) (static error band at 25 °C room temperature)
Operating temperature*...-30 °C to 130 °C
solution provides high Physical Storage temperature*......-40 °C to 140 °C
Proof pressure..............>2x operating pressure Room temperature resistance at 25 °C
performance and easy Burst pressure..............>3x operating pressure
Cycle life (Full scale)........>1 million cycles
• 10 or 100 kOhms
Supply
Pressure
applications. Thermistor
output Ground
ø 13 (0.51)
ø 6 (0.24)
Differential Pressure
Sensor are Micro- Technical specifications
Electro-Mechanical- Pressure range Thermal effect...................±3 %
0.18 to 1.5 bar rel (2.6 to 21.8 psig) (over the whole temperature range)
Systems (MEMS). Our Output response time
Physical • Min..................................10 ms
patented MEMS Proof pressure • Max.................................1.2 s
• High side...............>1.5x operating pressure Operating temperature....-40 °C to 140 °C
products offer the best- • Low side................>0.5x operating pressure
Burst pressure..........>3x operating pressure
Storage temperature.......-40 °C to 140 °C
Cycle life (Full scale)....>10 million cycles
value solutions for Vibration (50 to 2000 Hz)..........16 g Electrical
Drop (any axis)......................1.8 m Supply voltage..................4.5 to 5.5 Vdc
differential pressure Pressure connection.............Tubular Output signal.....................0.5 to 4.5 Vdc
(ø 6 or 8 mm) Supply current...................<15 mA
applications. Electrical connection............RD (P65/67/69k) EMC (1 MHz to 4 GHz)............100 V/m
ESD (ISO 10605)....................8 kV
Performance Protection
Accuracy (Full scale pressure)....±1.5 % • Overvoltage....................16 Vdc
(static error band at 25 °C span including linearity, • Reverse voltage..............-14 Vdc
hysteresis, repeatability, calibration) • Short circuit
23 (0.9)
(0.5) 71 (2.8)
26.4 (1.04)
23.5 (0.95)
21.8 (0.96)
AMP MQS - 4 pins Sicma VDA RD
19.6 (0.77) 12.9 (0.51) 22.3 (0.88)
13.8 (0.54)
34.1 (1.34)
70.1 (2.76)
34.4 (1.35)
27.1 (1.07)
1/4” SAE female flare with M10 x 1.25 female M10 x 1 male M12 x 1 male M12 x 1.25 male
deflator (7/6” - 20 UNF - 2B)
13.7 (0.54)
12.7 (0.5)
11.3 (0.45)
10.9 (0.43)
10.3 (0.41)
8.9 (0.35)
6.9 (0.27)
Hex 15.7 (0.62) Hex 14 (0.55) 10 (0.39) 12 (0.47) 12 (0.47)
M12 x 1.5 male M14 x 1.5 male M18 x 1.5 male 9/16” - 20 UNF male 3/8” - 24 UNF male
19.3 (0.76)
16.2 (1.48)
14.5 (0.57)
13.2 (0.84)
15.5 (0.6)
9.8 (0.39)
9.8 (0.39)
7 (0.28)
1/2” - 20 UNF male 7/16” - 20 UNF male 1/8” - 27 NPTF male 1/4” - 18 NPTF male 1/4” - 19 BSPT male
Hex 17.5 (0.69) Hex 15.9 (0.63)
17.5 (0.69) Hex 17.5 (0.69)
25.1 (0.99)
24.3 (0.96)
19.9 (0.78)
20 (0.79)
14.5 (0.57)
15.3 (0.6)
10.6 (0.42)
12.7 (0.5)
10.3 (0.41)
9.2 (0.36)
12.7 (0.5) 11.1 (0.44) 11.4 (0.45) 14.6 (0.58) 6.4 (0.25)
Project
Name Start of production
Target price Estimated usage Year 1 Year 2 Year 3
Application
Description Medium
Function of sensor
Pressure output
Operating pressure range / - differential (in bar absolute or relative)
Operating pressure range high side and low side (for DPS Series only)
Output signal (e.g. V, mV or mA) Full scale accuracy (including linearity, hysteresis, etc.)
Pressure connection
Material (e.g. brass, steel, stainless steel) Pressure connection
Material O-ring (if applicable)
Electrical requirements
Connector type Supply voltage
Output load (resistor value and pull up or down)
Response time (10…90 %)
Environmental conditions
Operating temperature range Life time
Proof pressure (max pressure applied without change of specification; high and low pressure side for DPS Series)
Burst pressure (max pressure applied without causing leakage; high and low pressure side for DPS Series)
Electromagnetic compatibility Vibration
Certificates / approvals IP class
Additional information
Sensata Technologies Holland B.V. Important Notice: Sensata Technologies (Sensata) reserves
the right to make changes to or discontinue any product or
service identified in this publication without notice.
Kolthofsingel 8 Sensata advises its customers to obtain the latest version
7602 EM ALMELO of the relevant information to verify, before placing any
The Netherlands orders, that the information being relied upon is current.
Sensata assumes no responsibility for infringement of
Phone: +31 546 879555 assistance or product specifications since Sensata does not
possess full access concerning the use or application of
Fax: +31 546 870535 customers' products. Sensata also assumes no responsibil-
www.sensata.com ity for customers' product design.