Professional Documents
Culture Documents
Broschyr98194 6
Broschyr98194 6
Multiparameter
HI98194
Multiparameter
Waterproof Meter
pH / mV, ORP, EC, TDS,
Resistivity, Salinity, Seawater σ,
Dissolved Oxygen, Atmospheric
Pressure and Temperature
Multiparameter
• Waterproof
·· IP67 rated waterproof, rugged
enclosure for meter, IP68 for probe
• Digital probe
·· Digital probe with three connections
for pH (ORP), EC and DO sensors and
integral temperature sensor
• Auto-sensor recognition
• Automatic logging
·· Store up to 45,000 samples
• Log-on-demand
·· Store measurement data at the press
of a button
• GLP
·· GLP data provides data from previous
five calibrations to ensure Good
Laboratory Practices are met
• Intuitive keypad
·· Hard and virtual soft keys
• Connectivity
·· PC connectivity via opto-isolated
micro-USB with Hanna software
www.makab.se
For Universal Applications Dedicated help button HI9828-25 “Quick
Calibration” solution
HI98184 provides multiparameter The contextual Help Menu can be accesssed
measurement in a compact and rugged, IP67 to obtain on-screen information and
waterproof enclosure. Ideal for demanding assistance about each feature at the touch
applications, each meter features our rugged, of a button.
Multiparameter
quick connect multi-function probe with field
• Field Ready with quick calibration solution
replaceable sensors.
Quick connect probe ·· Standardize pH and conductivity with
one calibration solution
A backlit, graphic LCD provides easy to The HI7698194 probe features a quick
·· Simply screw the calibration beaker
read resolution even in low-lit areas. A connect DIN connector to make attaching
filled with HI 9828-25 (500 mL) or
combination of dedicated and soft keys and removing the probe simple and easy.
HI9828-27 (1 gallon) solution onto
allows easy, intuitive operation in a choice
the probe, select “Quick calibration”
of languages.
from the menu and press OK. Individual
calibration may also be performed using
Data Logging multiple calibration points
The HI98194 allows users to store up to
45,000 continuous or log-on-demand
samples with logging intervals from one
second to three hours. Logged data can be
later transferred to a PC with the HI920015
micro USB cable and Hanna software.
• Setup
·· Extensive setup screen features
pH Specific Features Dissolved Oxygen
• Calibration Specific Features
·· Up to a three point calibration with • Choice of units
five standard buffers and one custom ·· Display units in % saturation
buffer available or mg/L (ppm)
• Autoranging
• Salinity readings
·· Practical Salinity Scale (PSU) based
on conductivity calibration
• rugged carrying case with custom
thermoformed insert included
www.makab.se
Probe Specifications HI7698194
Sensor inputs 3 (pH, DO, EC)
Body ABS
Threads Nylon
O-rings EPDM
Multi-function Sensor
• Quick sensor replacement
·· Sensor replacement is quick and easy with field replaceable, screw type
connectors and are color coded for easy identification. The these meters
automatically recognize sensors
or
DO (% saturation and
Measurement Type pH, mV (pH) pH, mV (pH/ORP) EC
concentration
0.00 to 13.00 pH; ±600.0 mV; 0.0 to 200.0 mS/cm; 0.0 to 500.0 %;
Measurement Range 0.00 to 13.00 pH ; ±600.0 mV
±2000.0 mV 0.0 to 400 mS/cm (absolute) 0.00 to 50.00 mg/L
Maintenance solution HI70300 (storage solution) HI70300 (storage solution) none HI7042S (DO electrolyte)
www.makab.se
Specifications HI98194
Range 0.00 to 14.00 pH / ±600.0 mV
Resolution 0.01 pH / 0.1 mV
pH / mV Accuracy ±0.02 pH / ±0.5 mV
automatic one, two, or three points with automatic recognition of five standard buffers
Calibration
(pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Range ±2000.0 mV
Resolution 0.1 mV
ORP
Accuracy ±1.0 mV
Calibration automatic at one custom point (relative mV)
Multiparameter
Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from
Resolution 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC
Accuracy ±1% of reading or ±1 µS/cm whichever is greater
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm,
Calibration
5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
Range 0 to 400000 ppm (mg/L) (the maximum value depends on the TDS factor)
manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L);
Resolution 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L):
TDS 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
Atmospheric Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
Calibration automatic at one custom point
Range -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K
Resolution 0.01°C; 0.01°F; 0.01K
Temperature
Accuracy ±0.15°C; ±0.27°F; ±0.15K
Calibration Automatic at one custom point
Temperature
automatic from -5 to 55°C (23 to 131°F)
Compensation
HI98194 is supplied with HI7698194 probe, HI7698194-0 pH sensor, HI7698194-3 EC sensor and HI7698194-2 DO sensor, Hanna PC software,
Ordering
HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and rugged carrying case with custom
Information thermoformed insert.
www.makab.se
HI98195
Multiparameter
Waterproof Meter
pH / mV, ORP, EC, TDS,
Resistivity, Salinity, Seawater σ
and Temperature
• Waterproof
Multiparameter
• Digital probe
·· Digital probe with two connections
for pH (ORP) and EC sensors and
integral temperature sensor
• Auto-sensor recognition
• Automatic logging
·· Store up to 45,000 samples
• Log-on-demand
·· Store measurement data at the press
of a button
• GLP
·· GLP data provides data from previous
five calibrations to ensure Good
Laboratory Practices are met
• Intuitive keypad
·· Hard and virtual soft keys
• Connectivity
·· PC connectivity via opto-isolated
micro-USB with Hanna software
www.makab.se
For Universal Applications GLP and On-Screen Help HI9828-25 “Quick
Calibration” solution
HI98195 provides multiparameter Comprehensive GLP data includes data from
measurement in a compact and rugged, IP67 last five calibrations. The contextual Help
waterproof enclosure. Ideal for demanding Menu can be accesssed to obtain on-screen
applications, each meter features our rugged, information and assistance about each
Multiparameter
quick connect multi-function probe with field feature at the touch of a button.
• Field Ready with quick calibration solution
replaceable sensors.
·· Standardize pH and conductivity with
A backlit, graphic LCD provides easy to Quick connect probe one calibration solution
·· Simply screw the calibration beaker
read resolution even in low-lit areas. A The HI7698195 probe features a quick
filled with HI 9828-25 (500 mL) or
combination of dedicated and soft keys connect DIN connector to make attaching
HI9828-27 (1 gallon) solution onto
allows easy, intuitive operation in a choice and removing the probe simple and easy.
the probe, select “Quick calibration”
of languages.
from the menu and press OK. Individual
calibration may also be performed using
Data Logging multiple calibration points
The HI98195 allows users to store up to
45,000 continuous or log-on-demand
samples with logging intervals from one
second to three hours. Logged data can be
later transferred to a PC with the HI920015
micro USB cable and Hanna software.
• Setup
·· Extensive setup screen features
pH Specific Features EC/TDS/Resistivity
• Calibration Specific Features
·· Up to a three point calibration with • Calibration
five standard buffers and one custom ·· Single point calibration from six standards
buffer available (84 µS/cm, 1.413 µS/cm, 5.00 mS/cm,
12.88 mS/cm, 80 mS/cm, 111.8 mS/cm
or custom point)
• Temperature compensation
·· Automatic Temperature Compensation
·· Configurable temperature coefficient • Guides
range from 0.00 to 6.00%/°C ·· On screen guides are displayed to help
·· Choice of reference temperatures you while performing procedures such
at 20 or 25°C as calibration
·· Absolute conductivity can be
displayed along with the temperature
compensated value
• Autoranging
• Salinity readings
·· Practical Salinity Scale (PSU) based
on conductivity calibration
www.makab.se
Specifications HI7698195
Sensor inputs two (pH/ORP, EC)
Body ABS
Threads Nylon
O-rings EPDM
Multi-function Sensor
• Quick sensor replacement
·· Sensor replacement is quick and easy with field replaceable, screw type
connectors and are color coded for easy identification. The these meters
automatically recognize sensors
or
Tip glass (pH) glass (pH); Pt (ORP) Stainless steel electrodes AISI 316
www.makab.se
Specifications HI98195
Range 0.00 to 14.00 pH / ±600.0 mV
Multiparameter
automatic one, two, or three points with automatic recognition of five standard buffers
Calibration
(pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Range ±2000.0 mV
Resolution 0.1 mV
ORP
Accuracy ±1.0 mV
manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from
Resolution 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC
Accuracy ±1% of reading or ±1 µS/cm whichever is greater
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm,
Calibration
5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
Range 0 to 400000 ppm (mg/L) (the maximum value depends on the TDS factor)
manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L);
Resolution 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L):
TDS 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
Temperature
automatic from -5 to 55°C (23 to 131°F)
Compensation
Battery Type / Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)
Dimensions / Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.)
Ordering HI98195 is supplied with HI7698195 probe, HI7698194-0 pH sensor, HI7698194-3 EC sensor, Hanna PC software, HI920015 micro USB cable, 1.5V AA
Information batteries (4), instruction manual, quick start guide, quality certificate and rugged carrying case with custom thermoformed insert.
www.makab.se
HI98196
Multiparameter
Waterproof Meter
pH / mV, ORP, Dissolved Oxygen,
Atmospheric Pressure and
Temperature
• Waterproof
Multiparameter
• Digital probe
·· Digital probe with two connections
for pH (ORP) and DO sensors and
integral temperature sensor
• Auto-sensor recognition
• Automatic logging
·· Store up to 45,000 samples
• GLP
·· GLP data provides data from previous
five calibrations to ensure Good
Laboratory Practices are met
• Intuitive keypad
·· Hard and virtual soft keys
• Connectivity
·· PC connectivity via opto-isolated
micro-USB with Hanna software
Multiparameter
quick connect multi-function probe with field feature at the touch of a button.
replaceable sensors.
Data Logging
TheHI98196 allows users to store up to
45,000 continuous or log-on-demand
samples with logging intervals from one
second to three hours. Logged data can be
later transferred to a PC with the HI920015
micro USB cable and HI929828 software.
• Setup
·· Extensive setup screen features
pH Specific Features Dissolved Oxygen
• Calibration Specific Features
·· Up to a three point calibration with • Choice of units
five standard buffers and one custom ·· Display units in % saturation
buffer available or mg/L (ppm)
• Temperature compensation
• Polarization
·· Automatic polarization of probe
at startup
• Membrane caps
·· Ready-to-use HDPE pre-tensioned
membrane caps are easy to replace
www.makab.se
Specifications HI7698196
Sensor inputs two (pH/ORP, DO)
Body ABS
Threads Nylon
O-rings EPDM
Multi-function Sensor
• Quick sensor replacement
·· Sensor replacement is quick and easy with field replaceable, screw type
connectors and are color coded for easy identification. The these meters
automatically recognize sensors
or
Maintenance solution HI70300 (storage solution) HI70300 (storage solution) HI7042S (DO electrolyte)
www.makab.se
Multiparameter
Specifications HI98196
Range 0.00 to 14.00 pH / ±600.0 mV
automatic one, two, or three points with automatic recognition of five standard buffers
Calibration
(pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
Range ±2000.0 mV
Resolution 0.1 mV
ORP
Accuracy ±1.0 mV
Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
Temperature
automatic from -5 to 55°C (23 to 131°F)
Compensation
Battery Type / Life 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight)
Dimensions / Weight 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) / 400 g (14.2 oz.)
Ordering HI98196 is supplied with HI7698196 probe, HI7698194-0 pH sensor, HI7698194-2 DO sensor, Hanna PC software, HI920015 micro USB cable,
Information 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and rugged carrying case with custom thermoformed insert.