You are on page 1of 1

Puskesmas Kelayang Mitra Ideal Consultant, PT (0001453)

Pad Footing Design Calc. By: Icank


0123 18/02/2021 Rev: 1 Checked By: Arie

Pad Footing Design


F1
FC1, FC2, FC3, FC4, FC5, FC6, FC7, FC8, FC9,
Columns:
FC10 (350.0 / 350.0 mm)

Critical Loading: (FC4 1: G*F) N = -42.9 t


Mx x My = 1.6 x 1.8 t.m

Footing Dimensions: Lx x Ly = 1700.0 x 1700.0 mm


h = 400 mm

Soil Stresses: σmax = 21.278 ≤ 30 t/m2 (1.5x20 t/m2) √

σmin = 12.821 ≥ 0 t/m2 √

Design:
X Dir: Bending: M = 4.7 t.m/m K/K' = 0.07≤1.0 √
As(Req) = 688.00 mm2/m As(Sup) = 804.25 mm2/m Y16-250
Chear Check:
(At Column Face) v = 40.80 t/m2≤ v-Rdmax = 405.00 t/m2 √
(At 'd' from Column) v = 19.52 t/m2≤ v-Rdc = 40.95 t/m2 √
Y Dir: Bending: M = 4.7 t.m/m K/K' = 0.08≤1.0 √
As(Req) = 688.00 mm2/m As(Sup) = 804.25 mm2/m Y16-250
Chear Check:
(At Column Face) v = 42.75 t/m2≤ v-Rdmax = 405.00 t/m2 √
(At 'd' from Column) v = 21.47 t/m2≤ v-Rdc = 40.95 t/m2 √
Punching Check:
(At Column Face): Vt = 47.2 t V-eff = 53.4 t
v = 110.92 t/m2≤ v-Rdmax = 405.00 t/m2 √
(At 'd' from Column): Vt = 34.9 t V-eff = 41.1 t
v = 36.04 t/m2≤ v-Rdc = 40.95 t/m2 √