TEST REPORT
2

Subject: P1515 TECEO with Standard flat glass protector (5mm thickness)
Sample n°: P-E112420

From: GZ Manufacturas Del Vidrio


Test purpose: Mechanical impact resistance test following IEC/EN 62262 Standard
Remarks:
Test request n°: P-D12112
Folder n°: P-F11258
1
2

TEST CONDITIONS: Operator: BOMBIL Patrick

Luminaire preparation for the test (standard body)


- 5 mm standard glass protector GZ with serigraphy
- 6 screws + steel washer
- Gasket 8 mm  (Co-Joint)
- New distribution of the impact points
- 2 samples for this test

At pendulum hammer
5 impact points distributed on protector surface
One impact on each point

Test Sample 1 Sample 2


IK08 : Impact energy: 5 joules OK, nothing to indicate OK, nothing to indicate
Hammer weight: 1,7 kg
Height of fall: 29,4 cm

1
2

CONCLUSIONS:

Five impacts distributed on translucent area of 5 mm protector give good result for target IK08 test.
Tested OK on 2 of 2 samples.

1
2

Duplicate to: MM G. Herman, C. Marville, Y. Borlez


LAB 12/03/2012 P-12E112
J.P. Harchies

page 1/1