You are on page 1of 1

The exact equipment along with their technical specifications for the following activities.

1. CW Measurement
2. Spectrum Measurement.

1. Receiver with fast scanner (The receiver scanner rate should conform to the Lee Criteria of 36 to 50
sample per 40 wavelength)
2. CW Transmitter
3. Base Station test antenna ( Omni-directional)
4. Accessories ( Including flexible coaxial cable/jumper, Power meter, extended power cord, GPS, compass,
altimeter etc ).

BAND – All the CW equipments (2.3 GHz).


Both the testing will be for LTE

Scope of Work for CW measurement

Identifying at least 10 sites per model per city for CW test to cover all clutter types and morphologies
adequately for model tuning purpose. It will bring us in comfort zone & to select any alternate option, if
any site found not fit for CW test during site survey.

Before conducting CW tests, a site survey will have to be carried out for each site and Survey Form to be
filled (as per Annexure A) to verify the locations of site, space/power availability, reassess the site
feasibility, pole locations etc.
All the CW equipments (2.3 GHz) and accessories to be arranged by Vendors. It is mandatory to use the
calibrated transmitter and receiver equipments. Calibration should not be older than 1 year.
Snapshots of installation of CW test equipments (2.3 GHz) and power measurement should be taken before
and after the drive test, Survey Form should be updated with relevant information including actual
transmitter antenna height. Carrying out a detailed drive test as per the route provided. Special care to be
taken, not to leave out any of the routes and collect maximum of data.
Indoor penetration loss measurements should be taken for at least 10 samples for each clutter category
(Skyscrapers, dense urban, and medium dense urban, low- dense urban, industrial, rural) in the city. The
sample should be taken approximately 2 meters from the wall with average taken over period of 1 minute.

Scope of work for Spectrum Measurement

Carrying out a drive test with RF scanner as per the route provided. Approximately 2000 Km per city. The
scanner shall be configured to scan 25 MHz bandwidth in 2.3 GHz band. The center frequency for the
scanner in any given service area (telecom circle) shall be communicated at the time of award of contract.
Thus 2.5 MHz of guard band on either side of the 20 MHz BWA channel will be covered in spectrum
scanning.

The test equipment required for the CW drive testing are Receiver with fast scanner (scanner rate should conform
to the Lee Criteria of 36 to 50 sample per 40 wavelength), CW Transmitter, Base Station test antenna, Accessories
Including flexible coaxial cable/jumper, Power meter, extended power cord, GPS, compass, altimeter

The drive route of the data collection is planned prior to the drive test using a detail road map.

For propagation model tuning, each clutter is tested individually and the drive route for each test site is planned
to map the clutter under-study for the respective sites. It is important to collect a statistically significant amount
of data, for each clutter category. The data should be evenly distributed with respect to distance from the
transmitter.