Universitat Stuttgart IGE Institut fir GebaudeEnergetik Latah or ele und Reumlutecnak test report for specific thermal output of floor heating construction in acc. to EN 1264 Freeheat SAS caleosol tradi 2E11 Priifbericht HB15 P414 ‘This repr const of 4 pages and 1 page appendix ‘The oport shal not be reproduced expect nfl wtnout the wlen approval ofthe testing lab ((paxxs ‘The test results relate only to the items tested. eeche ‘The test laboratory is accredit in acc. to ISO/IEC 17025 by DAkKS. Minecearee Bisnozraro ‘Acceptances from certification bodies: DINCERTCO/ RAL/ AFNOR / BSI / AENOR report no.: HB15 P414 page 1 of 5 I G E Institut far GebaudeEnergetik specific thermal output, {eneatnt or Herz: una floor heating system Ravmisttechn in ace, to DIN EN 1264-2 and DIN EN 1264-4 4. test method: intial test of floor heating system 2 Institut: Institut fur GebaudeEnergetik Lehrstuhl fur Heiz- und Raumlutttechnik der Universitat Stutgart Pratfenwaldring 35 70860 Stuttgart 3. client: Froeheat SAS 6, route des boutonniére £41000 St. Denis sur Loire (France) manufacturer the client 5. system description: trademark ccaleosol tradi 2E14 ‘construction: dry system (constuction tye Bin ace. to DIN 18560 1.2) (Option spacing in m 0.100 0,200 test sample ie CGIACONIN PE-RT/EVOHIPE-RT 1613 Sm (sauarstoiicht) materi PERT diameter oo om rmekness 00015 ft neat conduct 0400 © Wim (-2 éata sheet of manufacturer / Giacomin France) covering . cituser pats. cituse pats of aluminium teks 050 mm heat conduct 200 wink swith 0090 =m resp. 0,180 m (Opten) (act. product) covering oad distbution ayer mater thickness heat conductivity. 0.020 033 Documents for examination ‘ry pte (Fate Fermaces, ype 2611) Wim (=> datasheet of manufacturer! Fermacet) “The bans forthe testing and cerca ate te flowing documents inthe urrent version. IN EN 1258-2 Wee 13 iw EN 1264-4 Nor 03 bin ceRcTO 6. Information about test methods Raumfachenitagrerte Hetz- und Kehlsysteme mit Wasser utenstomung ~Tell2: FusbodenPezung Provertahren for die Bestimmung der Wirmetestung unter Bontzung von Berechnungsmetheden und expermentalen Wethoden, und Kuhlsysteme mit Wasser- ‘durchsvomung=Toll4: Inston Zertzerungsprogramm Stand November 2009 ‘The system has been tested with calcualtion methed (version HB16 P4414 xis) ‘An additional experimental testing is not required 87.5 7. test results: (option) Limit specific thermal output in Wii: O77 Limit temperature difference in K; WA 184 “This report consis of 4 pages and t page appendix. The report shal net be reproduced expect in ul witout the witten approval ofthe testng lab, The test results relate onl othe terms wate Institut Pratienyy ‘Stuttgart, 26.06.2015 t Prof. Drag, Nt Schiniat = GobaudeEner ding 35 fe (+49)7 11 | Luni-stat do Dr-ng. Chr. Beck reportno.: HB15P414 page 20f5 IGE 8, calculation results: cx ae: pent " a ered Institut far GebaudeEnergetik Lobatto Hetr ura Poumiumechn characterlatic curves: Tate aa as oor oo 05 | 059 | 0s seacng T etl Sa Dl wer Te (open 0100 S707 [4907 | —aaeo_| 200 _| wink 0200 4753_[ 3.700] —a,628-[ 2,566 | Wir, limit curves: Cpt: This spacing is ot inthe acta produet fer aera T= To m= oe Foor coverng aoe [00s | ono [ans [a 7 Tina triperaturecternce wa [28 | 28a | oat K K Tit speci ermal cut s77-| 200] 083] ss War 15 Lint emperstvre aiorencs so —aox-[ sos] eo t K Lit spect ermal output Tis es | 37 | wine Ths spacing le the actual product offer Spacing T= a0 m= oe Toor coven aeons | oro [ts ro 7 Tint Tenparatvreciterones Tea 26_[ 383 ra k iit specie thermal ipl as 37-208 nF 15 Lit temperatreaferones 319 s28-[ 633 © K Lint specie heal ovpul isi eo] 623 Ti report no.: HB15P414 page 3 of 5 IGE diagra specific thermal output in Wim? me Institut far GebaudeEnergetik Letrstun tar Hew und spacing T = 100 mm (Option) specific thermal output in Wim? oF — o 5 1 15 20 2 30 3 40 45 50 55 60 temperature difference in K oT == oct === 0008 spacing T = 200 mm (actual product) 160 140 120 100 80 | 60 40 20 0 5 10 1 2 2 30 3 40 45 80 55 60 temperature difference in K ~e.ro=rew 65 70 6570 reportno.: HB15P414 page 4 of 5 IGE 8. construction drawing of test sample: counties fs ov a5 GebaudeEnergetik Lottan tr : ete: une z aumlatechok VEE EEE oon Fermacel 2011 Tolérances générales +0. mm ssauf quand mentionné autrement 20 wt 10, Picture of test area: ‘The test area was bul on 25.6.2015 in the Institut. The used material was sended directly by the client. The construction is equal to the nominal construction of the drawing and the technical ‘ocuments, 11, conformity of the technical documents ‘The system is type B of DIN 18560 part 2 ‘The sketch of the technical documents are in acc, to EN 1264 part 4 ‘The officiel technical documents should be sended to the Institut within 6 months report no.: HB15 P414 page 5 of 5 IGE APPENDIX Institut for GebaudeEnergetik ‘Option: This spacing is no inthe actual product offer Lohrtut for spacing T= Hae und taestance ot or covering ooo [0,080] TET] mk Ravmlutachnk eco 8 607 B00] vane fac ay 7,000 spacing factr a: spacing exponent veg eto a factory A calculation factors: factor ac It curve coticurt Bo Inet euve exponent “This spacing Is the actual product ottor Rohrabetang Ts 000_m reaslance of for coving 00 [ 0,050 [0.100 [0780] mw {actor es8 | 0765 | 6 700_[ 6677] wmex face 4.000 — 0767 | —o649-| 0.582 spacing acter a 1066 spacing exponent 667 ‘veg face aU, 901 facor 0: 0.500 vue ot ‘oz acer a 586 face 0.520 Imiteove octet 8: Tae Em euve exponent ns 0.058

You might also like