SERVICE CSSSTE/ crranon LETTER July 16, 1982 SL34-28 TITLE J.E.1. Gyro Emergency Power Supply Fuse Failure Self Test, A-SB501-1228-7 EFFECTIVITY Model unit Number 500/501 0001 and On All aircraft equipped with J.€.T. Gyro Emergency Power Supply, type PS-835. REASON Jet Electronics and Technology has issued the attached Service @ulletin No. A-SB501-1228-7 to provide self test capability of the power supply output as well as battery output to detect possible fuse failure. COMPLIANCE Mandatory at the next repair period or no later than November 20, 1982. INSTRUCTIONS Any authorized J.E.T. Power Supply Warranty Overhaul Center will perform this modification at no charge to the operator for compliance with J.€.T. Service Bulletin A-SB501-1228-7. A list of these centers is printed on the last page of the J.E.T. Service Bulletin. The modification kit listed in this bulletin can be ordered through a J..1. Product Distributor or through the J.E.T. Grand Rapids office. A list of these facilities is also printed on the last page of the J.€.T. bulletin. All necessary procedures are transmitted in the J.£.1. Service Bulletin. COMPLIANCE REPORTING A Maintenance Transaction Report indicating compliance with this mandatory service letter must be completed and forwarded to CESCOM, P.O. Box 7706, Wichita, Kansas 67277. Citation Marketing Division Cessna Aircraft Company, P.O. Box 7706, Wichita, Kansas 67277 U.S.A. 316/946-6000, Telex: 417-370 ia JET ELECTRONICS AND TECHNOLOGY, A~SBS01-1228-7 5353 52nd Street, S.E. Grand Rapids, Michigan 49508 ALERT May 20, 1982 EFFECTIVITY PS-835( ) PCN 25832 COMPLIANCE Mandatory at next repair period or within six months of receipt of this bulletin. COMPONENT Emergency Power Supply SUBJECT Installation of PS-835A Mod 6, PS-835SB Mod 7 and PS-835C and D Mod 1 PURPOSE To provide self test of power supply output as well as battery output to detect possible fuse failure. PARTS REQUIRED A 12 inch piece of 22AWG, black, multistrand wire and 1 MS3368-3-9C tie-down strap. MANHOURS REQUIRED Two manhours are required to perform this modification. INSTRUCTIONS NOTE If the PS-835 Emergency Power Supply is in- stalled in the manner shown in Pigure 1, the system test will not detect whether the PS-835 battery protection fuse has blown. If the battery self test feature is being utilized as a pre-flight check of the PS-835 Emergency Power Supply, the battery protection fuse condition is not checked. In any application of the power supply, where failure to get the 28VDC output in an emergency situation would result in a flight safety hazard, this modification should be installed immediately or addi- tional pre-flight checks should be de- vised to insure that the battery pro- tection fuse is good. & 4 a Service Bulletin SB501-1228-7 In the design configuration setup with an attitude indicator, placing the setup in the emergency mode without the aircraft battery switch on,will cause the indicator power warning flag to retract, proving that the fuse is good. In aircraft required to opera third attitude indicator from a separate power source in accordance with FAR Part 25.1303(b) (4) PAR Part 29.1303(g), FAR Part 91.33 (4) (3) (i) or (ii), FAR Part 121.305(f) or (3), or FAR Part 135.149(c), this test must be used until the modification required by this service bulletin is installed. In other applications (communications, light- ing, etc.) a similar check (removal of air- craft power and operating the equipment from the PS-835 only) should be devised to determine if the fuse is good. After installing this modification, the added checks can be deleted. Refer to figure 2 and remove two screws (3), washers (6), lock washers (5) and nuts (4) from rear of unit and remove unit (2) from case (1). In the following steps, refer to figure 3 unless otherwise indicated. Remove two screws (36) and screw (7) loosening inverter support (11) permitting easier access to Printed Wiring Board (PWB) (22) terminals. Remove two screws (12) loosening support assembly (10) permitting easier routing of wires. Remove two black wires that are connected to PWB (22) terminals at location @}. Use a low wattage soldering iron and solder wick to remove wires. NOTE It may be necessary to_cut tie-down strap (33) and pry battery @) loose from ad- hesive if support assembly (10) freedom is insufficient to permit access to battery terminals. Remove black wire from battery @) negative terminal. Trim sleeving and connect and solder Slack wire removed from in step 4 to battery (3) negative terminal. (This wire comes from fuseholder (17). Service Bulletin $8501-1228-7 masons f PS-835 Interconnect Figure 1. Service Bulletin $B501-1228-7 Figure 2. PS-835 ' ) Emergency Power Supply Service Bulletin $B501-1228-7 Figure 3, Battery Circuit Card Assembly (Al) 10. ll. 12. 13. Service Bulletin SB501-1228-7 Install the 12 inch piece of 22AWG, black, multistrand wire between PWB (22) location @9 and PWB (22) terminal Route along edge of support assembly (10), through hole to. vicinity of © + Connect and solder at both ends. If_it was necessary to remove battery from adhesive, resecure in posi- tion with tie-down strap, MS3368-3-9C and Dow 732 RTV Silicone Adhesive. Install two screws (12) to frame (46). cure support assembly (10) to Install screw (7) to hold inverter support (11) in position. Set distance between support plate (10) and frame (46) connector (14) plate at 3.350 inches and secure in position with two screws (36). Refer to figure 2 and place unit (2) in case (1) and secure with screws (3), washers (6), lock washers (5) and nuts (4). Perform periodic test per paragraph 3-7 of PS-835 Overhaul Manual, TP-329. Refer to figure 4 for schematic revisions. Mark TP-329 Pigure 6-1 to show modification, Mack off modification dot on identification plate (17) follows and return unit to service. PS-635A - Mod 6 PS-835B - Mod 7 PS-835C - Mod 1 PS-835D - Mod 1 4 Figure 4. Schematic Revision ee Approved By WARRANTY OVERHAUL CENTERS (Ronee Siopioe ane se are) ‘Garcon iy NY (816) 222 000" ‘Aero Guay Sales Company. ne. iam Fs 2025056 SEES Snaten tt) 772.7010 Froeina Mat asesan Giendae Ca (213 6-013) ombs-gates Avion ‘Gonaoidated Arrat Supp in, SSyaie Nise sabsaat PRODUCT DISTRIBUTORS. Datos Teicha) 3s6 ner ‘ete Quay Sais Company. ‘ero Quality ales Company: te. JET ELECTRONICS AND Telepone iH 9496600 Toxan eas seTeLeCTEC Googe Aumotve euton rise 4ae ‘Hemet aucralinsrument corp Reston sve 735-2200 nywars Ca) 7859995 Peet EIS ze 2720 Setows Mo ie) 12a "Rend Bees ESTOS Toronto ONT aig) 781-1571 “Aircrat Equipment Overhaul Salen Senay nWencatane NAC irr ent Co. inggra lean Engiening PEL * cantar authorand tor State vers Beret 63 (S00 Ses" ia Amerce Aoi atiouar

You might also like