You are on page 1of 13
Metro Works Icr INC. Rlnce Centr E Rosigu I. Ave OUTSIDE PLANT DESIGN PROVINCE OF CAPIZ ROXAS CITY PANAY ISLAND tne A iscis CICT-MW PANAY ODN PROJECT RCZ0054-PO107_HERMANO SUBDIVISION RCZ001 AS BUILT REDLINE HEED-AS-PLAN >) C4 ser & Pr ower) CONVERGE Meme Wome | ter SoLurions Inc. Secenions eto TABLE OF CONTENTS COVER PAGE CONSTRUCTION NOTES LEGENDS KEYMAP WITH GRID GEOGRAPHICAL MAP S2oveD FOR IMPLI ‘SINGLE LINE DIAGRAM y TRANSMISSION PARAMETERS | SPLICING DIAGRAM converce (ptm.cone ean CONSTRUCTION NOTES ‘SECURE ALL THE NECESSARY PERMITS AT ALL CONCERNED AGENCY, 1 WOR SHALL CONFORM WITH TELECOMMUNICATION STANDARDS. AND SUILDING/OWNER REQUIREMENTS | PERFORM ACTUAL SITE STAKING PRIOR TO WATERIALS REGUISITION. AND CONSTRUCTION OCCURRED. STE INSTRUCTION WILL BE ENGINEER AT SITE DISCRETIONS AND APPROVAL ALL WORKS SHALL FOLLOW THE STANDARDS, UNLESS OTHERWISE SPECIIED, ALL PROPOSED CABLES ARE GECORE,SNGLE MODE,FIG.8 FOC UNLESS OTHERWISE SPECIFED.(48,96,216F) [ALL PROPOSED POLES MUST BE HEIGHT OF 9.0 METERS UNLESS OTHERWISE SPEC ED. ALL ROAD CROSSING MUST BE AT HEIGHT OF 7.5 METERS FORM THE GROUND LEVEL TO THE LOWEST POINT OF SAG. PRIOR TO THE INSTALLATION OF AERIAL CABLES, TRIMMING OF ALL OBSTRUCTING TREE BRANCHES SHALL BE AS REQUIRED. 10. ALL WORKS AFFECTED CONCRETE ROAD BREAKING MUST 2E RESTORED. 11. FOR LEP AND NAP LOCATION.PROPOSED NEW POLE MOUNT LGP AND NAP POSITIONS ARE FXED ANO INSTALLED FACING ROAD] st 12, USE CIRCULAR CONCRETE FOLE~7.5m,10A(270kg) FOR NON-DEFLECTIVE ATTACHWENT.USE_7.5m(480kq) FOR DEFLECTIVE ATTACHMENT.USE 9.0m 7AR(630kG) FOR ROAD CROSSING/TRAVERSE ATTACHMENT AND RISER POLE. 13. POL POLE SHOULD HAVE 20m WAINTENANCE LOOP WITH MESSENGER WIRE IN THE CABLE HOLDER ON CO SIDE. 1 PROVIDE 20m MAINTENANCE LOOP_WTHOUT MESSENGER WIRE FOR EVERY LO? ON CO SDE. 15. INSTALL LCP AND NAP 1 TO 2 FEET BELOW CENTER BOLT OF POLE CLAMP. COND OREN 18 AVOD CUTMING ALL CORE DURING SPLICING, TERMINATE ONLY THE ASSIGNED CORE. 19. PROPOSE CLOSURE IN EVERY BRANCHING AND PROVIDE 5m MAINTENANCE LOOP. 20. AVOID ATTACHING TO AN ELECTRICAL POLE WTH TRANSFORMER AS LEGEND /ED FOR IMPLES wei | [payeiowbiegsy ow TROWC TUCTION ING, es ral fe br =a ql e T tc ON VE RGE joni ames tea ein =o foonverse cates ets Soares RCZ001 BRGY.TANQUE, ROXAS CITY, CAPIZ ROXAS CITY, PANAY ae omnes Go GED es ROXAS CITY Lop Mo uce wo RCZOO1 RCZOO1 RCZ001 LOPH42- LOP Ha No. RCZO01 LCPS5- .RCZ0084-POI07 HERMANO SUBDIVISION PO 07 NAPI NAPS. Foner a ‘HERMANO SUBDIVISION LCP4#+4 NAP2 NAP4 Re200t aoe SCS eee 7 E 8 SINGLE Une DIAGRAM acts! pRoraseD pour ‘CcFa1 pRorosen po.e CE oper iscvenure ore -= RCZOO1 oe LoPH4 No HT NAP7 | Be N | aaca| cicrsiproroseBP8le cies! | = ae aceon | = LF \I2 RCZOO1 RCZOO1 aM | Lops: CONVERGE . ea, a es | "" cicTs| PROPOSED POLE cIcTS| PROPOSED ROLE ‘Barangay Ugg, Fs ty PoPeples | |semsomtpt| gig — c en Ext cicTs, PROPOSED POLE” CICS! PROPOSED POLE == a TRANSMISSION CHARACTERISTICS ‘LINK BUDGET LOSS © 1550nm 0.2146, ons ee Seems] omen fe ceeee| ree] mpm | ce aur | om mee | ee ‘anne vo | oc ‘thon con | sc eae =e a er on | 0 | ons wo | cos | aa ear pp PROJECT TITLE ‘OUTSIDE PLANT DESIGN 'PROVINCEOF CAPIZ ROXAS CITY CICTAMW PANAT ODN PROJECT {P0107 HERMANO SUBDIVISION} TRANSMISSION CHARACTERISTICS ‘HERMANO SUBDIVISION TW BUDGET LOSS @ 1480nm 0.2448 in ans ota wmmve| reine |wrommen| soos | ego | cos, | EE | = AOTLAN uevsion Oe | | i a cr | ear | wo | om aos _| 2178 | ee = KEE ste ie TRANSMISSION CHARACTERISTICS THK BUDGET LOSS © 1310nm 0.3608 CONVERGE anes) mone [ogee] cc) ome | ce [SRE | me 0 Rlarcn Cont Roster. (28) ‘Barangay Ugong, Pasig City Philippines vo | 1 | one cos | 21 ns ee ominous mod bier — —— | aia = Lop § SPLICING DETAILS “Qans 1 0. are © es = PO!07 a eo = LOP+44 to = = = NA-N2 oral eee Geis bd = — = fou PROJECT TITLE | OUTSIE DESIGN | cae + copad ame uf oo = oe mu [ 8. LcP. SPLICING DETAILS ‘CICTSI PROPOSED POLE POI07 LoPais ) | fc ONVERGE 100 Relarca Cetera We. (05) Brargay Upong 289 Oy Pines LeP ‘SPLICING DETAILS ‘CAPCO POLE (5737) Po107 LOPH6 WL FIQLePiie i Ka ee i Hn iy! — ‘OUTSIDE PLANT DESIGN ‘PROVINCE OF CAPIZ CCICT.MW PANAY OON PROJECT |RCZ0054-POIOT_HERMANO SUBDIVISION PROJECT TITLE ROXAS CITY

You might also like