You are on page 1of 1
~ FLOWSERVE — PROJECT: MNPL CUSTOMER : KALPATARU POWER TRANSMISSION LTD ‘CUSTOMER PO: 2300123191 DOCUMENT: GAD Rev-1 COMMENTS RESOLUTION SHEET Section/Ref GAIL/Mecon/KPTL comments Rev-0 | FICPL reply vide Rev-1 General Mention the type of sealant used Noted & incorporated (Sealant:-733) General Surface preparation and painting Incorporated details General Remove the quantity Noted & done General Mention the one material in BOM for | Noted & done Plug General ‘Add name plate details 3s per ‘Name plate details enclosed: API6D.Also add name of Mecon & Mecon & GAIL name added in Separate GAIL inthat Tag plate General End flange dimension standard Incorporated ASME 16.5(2020) 5007986-110 | Provide the detailed view of butt | Incorporated (tuin-aP-1755- | weld ends as per ASME 16.25 21-RV-10) 5007986-110 | Mention 300 mm distance b/w Gear | incorporated (1wnan-ap-1755- | box bottom & sealant extension top 21-PRV-10) 5007986-110 Height of extended column form Incorporated (MININ-AP-1755- | Valve opening centre shall be 3000 21-pav-10) | mm For all flanged Specify flange dimension tolerance as No tolerance for the Flange dimension as valves per ASME16.5 ( per ASME 16.5 2020) 5007986-60 | Mention socket dimension as per | ASME 16.11 & 855353 willnot have (wwin-ap-a75s- | 835353 difference forthe size. 21-PRV-60) : - '5007985-70'to | Test pressure for UCBtoeb revised | Revised as desired 90 to 155 bar ( body) & 114 bar ( seat) Please note that Max test pressure for LCB as per Standard is 144 bar only. Flowserve recommends not to overpressure the valves beyond standard lirnit Mention the GAIL PO no issued to Kalapataru Incorporated