You are on page 1of 1

CHIMNEY DESIGN CALCULATION

CODE : I.S. 6533 PAGE 1 OF 14


CUSTOMER : VJPN,ANK
CHIMNEY DIAMETER-TOP D1(IN cm) : 150
CHIMNEY DIA BOTTOM BD (IN cm) : 200
CHIMNEY HEIGHT TOTAL H( IN cm) : 4500
CORROSION ALLOWANCE : MM 2
ALLOWABLE BEARING ON FOUNDATION Ff( IN KG/cm2) : 20
ALLOWABLE BENDING STRESS-BEARING PLATE Fbp( IN KG/cm2) : 1650

DIA D1 DIA D1' D AVG SECTIONAL HEIGHT SHELL THICKNESS


( IN cm) (IN cm) (IN cm) (IN cm) (IN MM) ( IN cm) Area kg/m2 kgs
SEGMENT I 170 170 170 700 8 170 10 1.00 37.366 78.5 2933.231
SEGMENT II 170 170 170 800 33 139 10 1.00 42.704 78.5 3352.264
SEGMENT III 170 170 170 800 85 139 16 1.60 42.704 125 5338
SEGMENT IV 160 160 160 800 123 136 16 1.60 40.192 125 5024
SEGMENT V 200 200 200 1500 111 146 16 1.60 62.65 125 7831.25
24479 Weight of the structure 26926.6
1400 base plate
58 Nut & Bolt Weight
2448 Staircase and Platform
DESIGN OF SEGMENT I 28384 Total
32642 15% Metal Loss
DESIGN WIND SPEED (Vz)= Vb X K1 X K2 X K3 ------ IS 875(3)- 1987 35000 Final Weight of the Chimney

WHERE K1= PROBABILITY FACTOR= 1


K2= TERRAIN FACTOR= 1.12
K3= TOPOGRAPHY FACTOR = 1
VB= BASIC WIND SPEED= 44 m/s

Vz = 49.28 METRES/SEC

DESIGN WIND PRESSURE PZ = 0.6xVzxVz NOTE: CONVERSION FACTOR


PZ = 1457.11104 N/M2 I N/M2 = 0.0000102 KG /cm2 98039.216
PZ = 0.014862533 Kg/cm2

WIND FORCE FL = Cf x Ae x Pz x 1.1 (Pz= WIND PRESSURE)

WHERE Cf= FORCE COEFFICIENT 1.2


Ae= EFFECTIVE AREA = AVG DIA x HEIGHT
Ae= 119000 cm2

1.1 = 10% INCREASED TO TAKE CARE OF WIND PRESSURE ON CAGE AND LADDER

WIND FORCE FL = 2334.606622 Kg