The fiberglass grating

system provides a cost effective functional


solution for all flooring, walking, decking and traffic
areas where superior performance in adverse conditions At FCI, different types of
and corrosive environment is desired. An option on all gratings are available including Molded Gratings
the grating series is angular quartz, epoxy bonded and Pultruded Gratings which further can be modified as
anti-slip surface, available for the specific areas per our customers demand.
requiring maximum skid resistance.
WHY Fiberglass Gratings!

Common to all grating series bonus important


advantages that our gratings inherently provide to many
areas of its application;

Resistance to
Fire Corrosion High Fatigue High
Chipping and
Retardant Resistance Strength Strength
Cracking

Shape High Impact Cost Electrically non Bidirectional


Versatility Strength Effective Conductive Load Bearing

Predictable
Light Uniform Low
Physical
Weigh Appearance Maintenance
Properties

Oil and Gas


Chemical
Offshore

Power Plant

Industrial
Mining
Oil and Gas
Pulp and Paper

Fire Equlpment

Marine

1
Light duty:
Resin systems
Bearing Bar Centers 1.2”
• Iso-phthalic Resins: Made with premium grade Bearing Bar per ft of width 10
Iso-phthalic resin which yields good chemical resistance
with high physical properties. This system is used in Open area 79 %
applications that do not require compliance with Standard Cross Tie Centers 6”
ASTME-84, Class-1, flame flatting.
Standard Panels 3 ft x 18 ft
• Fire Retardant Iso-phthalic: Made with a premium
grade fire retardant Iso-phthalic polyester resin which 36”
meets with ASTM E-84, Class 1, Flame rating and
self-extinguishing requirements of ASTM D-635.

• Vinyl Ester: made with a premium grade ester resin

0.625”
system for severe corrosion application requiring better
resistance to alkaline and acidic environments. This
system is used in applications that do not require
compliance with ASTM E-84, Class 1, Flame rating.
0250” 0.95” 1.2”

Pultruded Grating
A grating series using I shaped Pultruded bearing bars
held together by two Pultruded cross tie components.
These cross tie components provide a mechanical lock
and fixed spacing for each bearing bar.
The T series having bearing bar and cross tie tops at
the same level, provide a flush top walking surface
affording maximum skid resistance lateral stability and
pedestrian walking comfort

2
Inches Load at
50 100 150 250 300 400 500 750 1000 1500
Span 25” def.

∆u 0.014 0.022 0.029 0.036 0.052 0.067 0.082 0.120 0.158 0.234 1603
12
∆c 0.018 0.030 0.042 0.055 0.097 0.103 0.128 0.189 0.250 0.371 1000
∆u 0.031 0.059 0.086 0.114 0.141 0.169 0.196 0.224 0.279 0.443 448
18
∆c 0.033 0.063 0.092 0.121 0.151 0.180 0.209 0.239 0.298 0.484 420
∆u 0.035 0.069 0.138 0.207 0.276 0.346 0.415 0.484 0.553 181
24
∆c 0.028 0.055 0.110 0.166 0.221 0.276 0.332 0.387 0.442 226
∆u 0.064 0.096 0.128 0.161 0.241 0.321 0.401 0.482 78
30
∆c 0.051 0.103 0.155 0.206 0.257 0.308 0.360 0.412 122
∆u 0.061 0.122 0.182 0.243 0.303 0.364 0.425 41
36
∆c 0.032 0.081 0.162 0.243 0.323 0.404 0.485 77
∆u 0.056 0.112 0.225 0.337 0.449 22
42
∆c 0.051 0.128 0.257 0.385 0.513 48

Load deflection data was derived from lab tests conducted by PCA. Values tabled are for design selection only and not
intended to be exact.
Medium duty:

Bearing Bar Centers 1.2” 36”


Bearing Bar per ft of width 10
Open area 67 %

0.625”
1.0”

Standard Cross Tie Centers 6”


0.312” 0.888” 1.2”
Standard Panels 3 ft x 18 ft

Inches Load at
100 200 300 400 500 1000 1500 2000 3000 4000
Span 25” def.

∆u 0.006 0.007 0.009 0.011 0.013 0.022 0.031 0.042 0.057 0.075
12
∆c 0.007 0.010 0.013 0.015 0.018 0.033 0.047 0.061 0.090 0.118
∆u 0.010 0.015 0.021 0.027 0.032 0.061 0.089 0.117 0.174 0.230 2900
18
∆c 0.013 0.022 0.031 0.040 0.049 0.094 0.140 0.185 0.275 0.366 2720
∆u 0.017 0.030 0.042 0.055 0.068 0.132 0.196 0.261 0.388 960
24
∆c 0.026 0.046 0.067 0.087 0.108 0.210 0.313 0.415 0.620 1200

3
∆u 0.028 0.053 0.077 0.101 0.126 0.247 0.369 405
30
∆c 0.046 0.084 0.123 0.162 0.201 0.395 0.590 633
∆u 0.045 0.087 0.128 0.169 0.211 0.417 199
36
∆c 0.071 0.137 0.203 0.269 0.335 0.665 372
∆u 0.070 0.134 0.199 0.263 0.329 108
42
∆c 0.111 0.216 0.319 0.423 0.527 237

Load deflection data was derived from lab tests conducted by PCA. Values tabled are for design selection only and not
intended to be exact.

Heavy Duty: 36”

Bearing Bar Centers 1.2”


Bearing Bar per ft of width 10
Open area 67 % 1.5”
Standard Cross Tie Centers 6”
0.888”
Standard Panels 3 ft x 18 ft
0.312” 1.2”

Inches Load at
100 200 300 400 500 1000 1500 2000 3000 4000 5000 6000
Span 25” def.

∆u 0.004 0.005 0.006 0.007 0.008 0.012 0.015 0.019 0.027 0.034 0.042 0.050
12
∆c 0.004 0.005 0.006 0.008 0.009 0.015 0.021 0.028 0.039 0.051 0.064 0.077

∆u 0.005 0.007 0.009 0.011 0.013 0.024 0.035 0.045 0.066 0.087 0.108 0.129
18
∆c 0.006 0.010 0.013 0.016 0.020 0.037 0.053 0.070 0.104 0.138 0.172 0.205

∆u 0.010 0.014 0.018 0.023 0.028 0.051 0.074 0.097 0.143 0.189 0.235 0.281 2660
24
∆c 0.011 0.018 0.025 0.033 0.040 0.077 0.114 0.150 0.224 0.298 0.371 0.445 3325

∆u 0.013 0.022 0.030 0.038 0.047 0.088 0.131 0.172 0.256 1170
30
∆c 0.019 0.033 0.046 0.060 0.073 0.140 0.207 0.274 0.409 1830

Load deflection data was derived from lab tests conducted by PCA. Values tabled are for design selection only and not
intended to be exact.

4
having certain length
Molded gratings and width with the tops of bearing bars and cross
bars in the same plane. Surface can be made anti-skid or
FCI molded fiberglass grating is a strong mesh grating gritted if required.
panel that is the chemical resistant flooring. The panels
are molded in one piece and feature a concave non-slip FCI grating is:
walking surface. The cost- effective panels allow for
efficient on-site cutting to minimize grating waste and • Corrosion Resistant
load bearing bars in both directions allow for use • Fire Retardant
without continuous side support. FCI molded fiberglass • Lightweight
grating is significantly lighter in weight than metallic • Easy to install
gratings and the high resin content provides excellent • Uniform in Appearance
corrosion resistance and requires very little • Impact Resistance
maintenance. Fiberglass molded gratings panels are of • Insulator
molded grid pattern. The grating is one piece fabrication • Cost Effective

Technical Data
Shapes, Sizes and Availability

FCI Grating Panels Specifications

Thickness Height Mesh Pattern Panel Size

4’ x 12’, Cut to Size panels are


0.3” 60 mm (max.) 1-1/2” Square
available as per client’s requirement.
Note: Any size/height and panel size can be fabricated upon customer’s choice in the 38mm x 38mm mesh pattern.

5
Maximum
Load in Pounds (lb) Modulus
Recommended
Span Mesh/ Ex106
60 100 150 200 250 500 1000 Load (lb/ft)
(in) Depth PSI
∆u <0.01 0.01 0.01 0.02 0.02 0.04 0.09 1800
12 0.3
∆c 0.01 0.01 0.02 0.03 0.04 0.07 900
∆u <0.02 0.04 0.06 0.08 0.10 760
18 0.3
Heavy Duty: ∆c 0.02 0.04 0.07 0.09 0.011 570
38mm x 38mm / 25mm

∆u 0.07 0.12 0.18 0.24 0.31 410


24 0.3
∆c 0.05 0.10 0.15 0.20 0.24 410
∆u 0.18 0.29 256
30 0.3
∆c 0.09 0.19 0.28 320
∆u 0.34 180
36 0.3
∆c 0.15 0.30 270

42 ∆c 0.24 220 0.3

Customized designed are also available as per client / site requirement.

Load deflection data was derived from lab tests conducted by PCA. Values tabled are for design selection only and not
intended to be exact.

Nomenclature:
∆u ∆c
Uniform Load Concentrated
line load

6
FRP Side Rails & Staircase
Are you an industrialist? If yes, then you must be worried You may install GRP handrail and stair treads to keep the
about the safety and security of your workers or staffs. stair of the building safe.
Now, what is the solution to this problem? How can you
make your buildings safe for the staffs as well as the 1. Advantages of FRP Handrails & Staircases:
visitors? The solution is the safety measure. You may
take some safety measure to minimize the risk rate in • Light Weight
the workplace. When it comes to safety measure • Corrosion Resistant
fibreglass or FRP is what that appears in everyone’s mind • High Resistant
first. Now you may ask how? Well, there are various types • Dimensional Flexibility
of products, structures and access systems which are • Fire resistant
made of glass fibre. Since GRP is non-slip in nature, the • Insulator
products, manufactured from this raw material are ideal • Cost effective
to reduce the risk rate.

7
FRP Structural Platforms
in the entrance of your building as this is non–slip. So,
The FRP platforms are much more durable than
this is how you will be able to keep your building safe.
aluminum or steel and the low electrical conductivity of
For the well-being and safety of your staffs, don’t forget
FRP makes the operating platforms much safer for
to install all the above-mentioned fibreglass accessories
workers. Additionally, the lightweight FRP shapes,
and structure.
grating and handrail made the installation easier and
faster. FRP platforms are a much better solution for
It is time to act. It is time to minimize the impact of
corrosive operating environments like those found in
corrosion on your bottom line. It is time to replace
refineries, steel mills, fertilizer industries and many
corroding stairs, platforms and ladders with durable and
chemical handling environments. The platform can also
surprisingly economical FRP ones. It is time to eliminate
protect the floor from getting damaged by the chemicals
workers injury by replacing corroded metal “safety”
and acids. As a result, fiberglass has become the material
landings by corrosion free FRP safety landings. It is time
of choice for such operations.
to provide safe access for today’s workers and for future
generations!
Most of the mishaps in the workplace happen due to the
slippery platform. You may install GRP grating platform

Quality control at FCI


Assures consistent production conformity to product
specifications by verifying that;

• Raw materials meet or exceed the required standard


and specification
• Processing conforms to established parameters in
accordance with developed quality plan.
• Product conforms to the required specification