You are on page 1of 1
KEl Industries Limited | saris, Sichercatcor Gn ste Registered and Corporate Office: 0-90, Okla Industrial Area Phase, New Delhi-110020 cm: L74e990L 1992PL. 0051527 Tek: 011-26818840/8642/0242, Fax: 26817225, 26811959 E-mal:epe@ketind.com Website: wow kind com Ref: - KEI-EPC/PGCIL/ARP-SS-04/2019-20/231, Date: -28/10/2020 Director (Enge-S/S) Power Grid Corporation of India Limited, Saudemini, Plot No.-2, Sector-29, Gurgeon (Haryana) - 122001. Kind Attention: - Sh. R.N Singh ~ED (ENG.) Subject: Re-amendment of Quantity of Erection hardware for 33Kv layout (Bus scheme as per SLD)- Transformer bay as per TS against Package ARP-SS04 including Transformers for i) Changlang S/s, ii) Jairampur $/s il) Khonsa S/s iv Miao S/s associated with Comprehensive Scheme for Strengthening of ‘Transmission & Distribution System in NER & Sikkim: Intra-State: Arunachal Pradesh Reference: 1. Tender Specification No.: CC-CS/165-NER/SS-3318/3/G10 2. NOA Ref. No.: CC-CS/165-NER/SS-3318/3/G10/NOA-II/7098 DT: 09.12.16 3, Tender document GA of electrical layout plan Dwg.no .C/ENGG/NER/ARP/MIAO/GA 01. 4.PGCIL Letter RefNo:C-ENG-NER-ARP-§S-04/QTY/VARIATION/03 DT:21.09.2020. S.KEI Letter No: KEI-EPC/PGCIL/ARP-SS-O4/2019-20/22S Dated 24.09.2020. 6. KEl Letter No: KEL-EPC/PGCIL/ARP-SS-04/2019-20/230 Dated 22.10.2020 7. PGCIL Email dt.22.10,2020 by Sh. S.J Lahiri GM (ENG.) Dear Sir, 0 KElis in receipt of email dt.22.10.2020 from Sh. S.J Lahirl- GM (ENG). In the aforesaid ema, Power Grid has given reference to Clause No. 6.3 and has specifically reproduced the following: For erection hardware items, Bidders shall estimate the total requirement of the works and indicate module-wise (bay wise) 2.0 In this connection, KEI once again submits that for erection hardware item, we have estimated the requirements module wise. 1n addition, it is confirmed that KEI submitted the bid on estimating lot wise requirement of erection hardware fitting as one single phase transformer for one set of Erection hardware for the 33Kv layout (Bus scheme as per SLD) ~ Transformer bay item. 3.0 In view of above, Power Grid cannot unilaterally change from 3 set to 1 set which is not in line with Clause No, 6.3 quoted above. Further action may please be taken as indicated/expiained above. ‘Thanking you and assuring you our best services all the times. For KELIndustries Limited ae Vice President ‘Mob: +91-8860635804 ‘Wt 9 BIN? RAS naa, Pha Bd De ar 01019 Rapetan Ta OVS OTRO Fa BETTIE a RATS HES Work: 99727, Mout esi sia, Rakal, Shass-S96240, DAN H. Tek (260-28cedD4DEOOOAe Fax: 2645606 Era: sass n.cm Work: A 260-268 AICO testa Area (Chparki) Ost lr Plastan-301019 Tel: 01499-26020206 Fac 260200 Ema: chaperkiatind.com

You might also like