Assemble pump device (Bearing Torque )

Measure the Sub-bearing of outer The results of pre-loads for sub-bearing


ring outside diameter. of outer ring outside diameter
Original Diameter: (As for it, the abnormal diameter of the outer
φ110: - 0.010 to 0 ring outside diameter is generated with 3 of 27)
Limit of Specified Torque:
φ110: + 0.005 to + 0.018 The pre-loads for
Pump casing inside diameter bearing is higher
φ110+0.018∼+0.004 than the limit of
specified torque.

The number of
+30∼50μm

testing

The limit of
単品 specific Over torque
Original torque

Page 16