N O T E : This product requires two power supply connections. The Motor Supply and Control Supply must
both be connected for proper operation.
External fuses or a circuit breaker (10 A maximum, time delay type) are required for the AC1 and
AC2 inputs for branch protection. The protective device should be located near the drive.
10 Chapter 2 www.aerotech.com
Installation and Configuration BL
See Wiring Configurations for information on connecting each of the supported motor types.
www.aerotech.com Chapter 2 11
BL Installation and Configuration
Switches 1-4 affect the full-scale current output range of the amplifier when in current (and in velocity) mode.
When all four switches are closed, the peak current range is not limited. Closing each switch effectively lim-
its the output range of the amplifier by a factor associated with that switch. For example closing only SW1-4
(54%) on a BL10 limits the output current to 5.4 A. Therefore, a 10 V input signal would produce a 5.4 A out-
put; similarly, a 5 V input would produce a 2.7 A output (5V / 10V * 5.4A). It should be noted that switches 1-4
have no effect in dual-phase mode.
Switches 5 through 8 determine the level where the continuous output current will produce a fault. This type
of protection is known as an electronic fuse.
12 Chapter 2 www.aerotech.com
Installation and Configuration BL
www.aerotech.com Chapter 2 13
BL Installation and Configuration
This figure illustrates a portion of the pre-amplifier circuit that is accessible to the user for adjusting com-
mand signal gains.
14 Chapter 2 www.aerotech.com
Installation and Configuration BL
www.aerotech.com Chapter 2 15