You are on page 1of 2

Leica FlexLine TS10

Manual Total Station

FlexLine

LEICA FLEXLINE TS10 MANUAL TOTAL STATION


n Work faster: measure more points per day due to faster measurements and
stakeout procedures, supported by the revolutionary Leica Captivate field
software. The software is made to make your work easier and more enjoyable.
n Use it trouble-free: increase productivity and minimise downtime by The Leica FlexLine TS10 manual total station combines
relying on instruments that simply work and come with a global service and user-friendly, ergonomic design with high-end reliability
support network. under harsh conditions. It enables you to tie into the
n Choose products that are built to last: even after years of use under harsh modern 3D dataflow, including enhanced linework and
conditions (like mud, dust, blowing rain, extreme heat and cold), FlexLine still coding. The TS10 offers mobile data device integration
operates with the same high level of quality. as an option. The larger, highly visible colour- and
n Control your investment: reliability, speed and accuracy ensure a lower touchscreen helps you to complete your surveying tasks
investment over the product lifetime and a higher resell value. with the highest speed and accuracy. The new FlexLine
n Save time with AutoHeight: this revolutionary feature enables the FlexLine generation of manual total stations relies on a proven
TS10 manual total station to automatically measure, read and set the product concept that has been revolutionising the world
instrument height. Errors are minimised and the setup process onsite is faster. of measurement and survey for nearly 200 years.

leica-geosystems.com
Leica FlexLine TS10
Leica FlexLine TS10
ANGULAR MEASUREMENT
Accuracy Hz and V Absolute, continuous, diametrical1 1’’ / 2’’ / 3’’ / 5’’
n Display resolution: 0.1’’ (0.1 mgon)
n Quadruple Dual axis compensation with Hz collimation and V index correction
n Compensator setting accuracy2: 0.5’’ / 1’’/ 1.5’’

n Compensator range: +/- 4’
n Electronic level resolution: 2“
n Circular level sensitivity: 6` / 2 mm
DISTANCE MEASUREMENT
n Prism (GPR1, GPH1P): 0.9 m to 3,500 m
Range ✔
n Prism GPR1 (Long Range mode) > 10,000 m
Non-Prism / Any surface
n R5003 ✔
n R1000 4 •
Single prism
Accuracy / Measurement time ✔
n 1 mm + 1.5 ppm (typical 1 - 2 s)
Non-Prism / Any surface
n 0 m - 500 m: 2 mm + 2 ppm (typical 2.4 s5) ✔
n > 500 m: 4 mm + 2 ppm
Display resolution: 0.1 mm ✔
n At 30 m: 7 mm x 10 mm
Laser dot size n At 50 m: 8 mm x 20 mm ✔
n At 100 m: 16 mm x 25 mm
n Magnification: 30x
n Resolving power: 3”
Telescope ✔
n Focusing range: 1.5 m / 4.92 ft to infinity
n Field of view: 1°30’ / 1.66 gon / 2.7 m at 100 m
GENERAL
5“ (inch), 800 x 480 pixels WVGA, colour and touch
Display and keyboard n 25 keys6a ✔
n 37 keys with function keys6b •
2nd keyboard •
Key illumination ✔
n Endless drives for HZ & V
Operation ✔
n Trigger-Key: user definable with 2 functions
Exchangeable Lithium-Ion battery7
Power management n Operating time with GEB361 up to 19 h
n Operating time with GEB331 up to 9 h
External supply voltage

n Nominal voltage 13.0 V DC & 16 W max
n Internal memory: 2 GB Flash / 4 GB Flash ✔/•
Data storage n Memory card: SD card 1 GB or 8 GB ✔
n USB memory stick: 1 GB ✔
n TI OMAP4430 1GHz Dual-core ARM® Cortex™ A9 MPCore™
Processor ✔
n Operating system – Windows EC7
Interfaces RS2328, USB device ✔
Bluetooth®9, WLAN10 ✔
Mobile Data sidecover: LTE-Modem for internet access •
n Working range: 5 m to 150 m

Guide Light (EGL) n Position accuracy: 5 cm at 100 m
(R1000)
n Wavelength red /orange: 617 nm / 593 nm
Accuracy
Laser plummet
n Plumb line deviation: 1.5 mm at 1.5 m instrument height ✔
(Laserclass 2)
n Diameter of laser point: 2.5 mm at 1.5 m instrument height
AutoHeight module for automatic Accuracy
instrument height measurement n Distance accuracy: 1.0 mm (1 Sigma) ✔
(Laserclass 2) n Distance range: 0.7 m to 2.7 m
Weight 4.4 - 4.9 kg
n Working temperature range: –20°C to +50°C ✔
Environmental n Arctic version: –35°C to +50°C •
specifications11 n Dust / Water (IEC 60529) / Humidity: IP66 / 95%, non-condensing ✔
n Military Standard 810G, Method 506.5 ✔
n 5 megapixel CMOS sensor
Imaging •
n Overview camera with field of view 19.4°
LOC8 Tracking and theft deterrence device •

Legend:
1. 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon), 5’’ (1.5 mgon) 7. Distance/angle measurement every 30 seconds ✔ = Included • = Optional
2. Angular accuracy / Compensator setting accuracy: 1“ /0.5’’ (0.2 mgon), 2“/0.5’’ (0.2 mgon), 3“/1.0’’ 8. 5 PIN Lemo-0 for power, communication and data transfer
(0.3 mgon), 5“/1.5’’ (0.5 mgon) 9. For communication and data transfer
3. R500: Kodak gray 90% reflective (1.5 m to >500 m), Kodak gray 18% reflective (1.5 m to >200 m) 10. For internet access, communication and data transfer,
4. R1000: Kodak gray 90% reflective (1.5 m to >1000 m), Kodak gray 18% reflective (1.5 m to >500 m) WLAN range up to 200 m
5. Up to 50 m, max. measurement time 15 s 11. Storage temperature: –40°C to +70°C
6. (a) Face I standard, face II optional, (b) face I optional, face II optional

Laser radiation, avoid direct eye exposure.


Class 3R laser product in accordance with IEC 60825-1:2014.

The Bluetooth® trademarks are owned by Bluetooth SIG, Inc. Windows is a registered trademark
of Microsoft Corporation. Other trademarks and trade names are those of their respective owners.
Copyright Leica Geosystems AG, 9435 Heerbrugg, Switzerland. All rights reserved. Leica Geosystems
AG is part of Hexagon AB. 02.21

Leica Geosystems AG
Heinrich-Wild-Strasse
9435 Heerbrugg, Switzerland
+41 71 727 31 31