2.2.

Connection of serial communication cable


To save the Stroke End data, connect the main unit box and a personal computer with the RS232C
cable (cross-cable). The data communication system is RS-232C.

RS-232C cable (cross-cable)

2.3. Connection of power cable


(1) Connect the power cable.

Power cable

- 3 -㩷 㩷 㩷 MED- Stroke End Monitor -IN-EN-01


2.4.2. AC90
2.4.2.1. Sensor box side
(1) Connect the I/O cable terminals to the sensor terminal block.
Sensor
I/O cable
terminal block
R505 B18
R507 B19
P24 B06

Sensor
I/O cable terminal block

2.4.2.2. AC90 side


(1) Disconnect the signal line (AMP 3P female connector) that is input to the I/O unit from the CFM.
Applicable I/O unit: 02h
Applicable signal lines: IN7, IN8

(2) Connect the signal line that has been disconnected from the I/O unit to the male connector
connected to the relay.
Relay terminal
Mark tube AMP connector CFM side
block No.
IN7 Male 9 IN7
IN8 Male 10 IN8

(3) Connect the female connector that is connected to the relay to the I/O unit (02h) inside the AC90
control panel.
Relay terminal
Mark tube AMP connector CFM side
block No.
IN7 Female 13 IN7
IN8 Female 14 IN8

- 7 -㩷 㩷 㩷 MED- Stroke End Monitor -IN-EN-01


2.5.2. AC90

Cable A for sensor head

Cable B for sensor head

I/O cable for AC90 connection

RS232C cable for AC90 HMI

- 9 -㩷 㩷 㩷 MED- Stroke End Monitor -IN-EN-01