STABILIZER INSPECTION REPORT

CUSTOMER: METAL MUNCHER OIL TOOLS. (MMOT) REPORT NO. PMTC/MMOT/TOOLS/KISH/12-21/004

WELL NAME : N/A DATE : 08.12.2021

LOCATION: KISH, IRAN PO No.: N/A

JOB NO. : PMTC/JN/12-2021/048

SPECIFICATION USED
DS-1 X Service Cat: 3-5 X Black Light connection LPT connection
API RP 7G-2 X VTI LPT Upset/Blade area
OTHERS X Dimensional inspection Blade Od ring gauging
NS-2 X MPI Upset/Blade area

Stab. Size & TYPE : 14 3/4'' STRING STABILIZER Serial No.: AM-PT-SSTR-1434015

BOX CONN. : 7 5/8 REG DIMENSION REQUIRED MEASURED DIMENSIONS


AREA IN INCHES
26''
BOX CONECTION
FISHING NECK LENGTH (A)
9 1/16'' C.BORE DEPTH 11/16
OD C.BORE DIAMETER 7 1/8
BEVEL DIAMETER 8 3/8
A
B.BACK CYL. LENGTH N/A
BORE BACK DIA N/A
BOX OUTER DIAMETER 9 1/16

1.968 m
14 3/4''
BOTTOM NECK LENGTH (B) 19 1/2
PIN CONNECTTION

OD PIN LENGTH 5 3/16


PIN THREAD LEAD OK
BEVEL DIAMETER 8 3/8
S.R.G WIDTH N/A
B
2 31/32'' S.R.G DIAMETER N/A
ID PIN OUTER DIAMETER 9 1/32
PIN INNER DIAMETER 2 31/32
PIN CONN. : 7 5/8 REG
BODY
BODY CONDITION: SCRACHED BOX CONDITION: OK PIN CONDITION: OK

COMMENTS: THE ABOVE MENTIONED TOOL INSPECTED AND NO DEFECTS OBSERVED AT THE TIME OF INSPECTION,
HARD FACE CONDITION FOUND SATISFACTORY AT THE TIME OF INSPECTION .
NOTE:
NOTE: BOTH PIN AND BOX CONNECTION HAVE NO SRG AND BOREBACK.
NOTE: BLUE HIGHLIGHTED DIMENSION ACCEPTED AS PER CUSTOMER SPEC.
NOTE: BLADE OD RING GAUGING NOT DONE AND GRINDING MARKS OBSERVED ON BLADE'S AREA.
CT - CORRODED THREAD , WT - WORN THREAD , GT - GALLED THREAD , DT - DAMAGED THREAD , ST - STRETCHED THREAD ,
LEGENDS : DS - DAMAGED SEAL , CS - CORRODED SEAL , BS - BOX SWELLED , CRG - CORRODED RELIEF GROOVE , RF - SEAL REFACED
CBB - CORRODED BORE BACK , CR - CRACKED , WO - WASH OUT , HBD - HARD FACE DAMAGED.

INSPECTOR: SAJAD ARIAFAR CUSTOMER REP.:


ASNT Level II Cert. No. TS /TSI-124/MT-II
ASNT Level II Cert. Validity 10.MAY.2026
Equipment Sr. No. Calibration Validity
AC/DC Yoke 2012072901 16.12.2021
Mag. Coil T-020 21.02.2022
Black light 1872078 16.12.2021
This field report is issued subject to the condition that it is understood and agreed upon that nothing herein shall be deemed to relieve any designer, manufacturer, repairer or operator of any warranty, express or implied and PMTC's liability shall be limited to the
acts and omissions of its employees and subcontractors. Under no Circumstances shall PMTC be liable for any injury or damage to any person or property occurring by any reason of negligent operation, misuse, of or any defect in material, machinery, equipment
or other items other than by defects in items actually inspected by PMTC and ascertainable by normally accepted testing standards, or defects reflected in documents reviewed by PMTC and which are covered by this report. this field report and the
recommendation contained within it are based upon the conditions and practices observed and information available to PMTC personnel. The report does not purport to list all hazards or faulty conditions not to indicate that other hazards or faulty conditions exist.
Severity ratings on the criteria shown in this report are intended as guideline only. PMTC does not accept responsibility for the control or correction of conditions

F OPN 007 TUB DS1, Rev.00 01.11.2020

You might also like