Professional Documents
Culture Documents
*CECHARGE
Specify concentrated electric charges in piezoelectric analysis.
This option is used to apply electric charge to any node in a piezoelectric model.
Level: Step
Reference:
Optional parameters:
AMPLITUDE
Set this parameter equal to the name of the amplitude curve that defines the magnitude of the
electric charge during the step. If this parameter is omitted, the reference magnitude is applied
immediately at the beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the *STEP option (“Defining an analysis,” Section
6.1.2 of the Abaqus Analysis User's Guide).
OP
Set OP=MOD (default) for existing *CECHARGEs to remain, with this option modifying
existing electric charges or defining additional electric charges.
Set OP=NEW if all existing *CECHARGEs applied to the model should be removed.
Optional, mutually exclusive parameters for matrix generation and direct-solution steady-
state dynamics analysis:
IMAGINARY
Include this parameter to define the imaginary (out-of-phase) part of the concentrated electric
charges.
REAL
Include this parameter (default) to define the real (in-phase) part of the concentrated electric
charges.
First line:
1. Leave blank.
file:///D:/Aplications/Documentation/docs/v6.14/books/key/ch03abk10.html 06/06/2018
*CECHARGE Página 2 de 2
Repeat this data line as often as necessary to define concentrated electric charges at various nodes
or node sets.
file:///D:/Aplications/Documentation/docs/v6.14/books/key/ch03abk10.html 06/06/2018