mechanical seal, external gear, and coupling losses, as applicable, and shall be in accordance with the

applicable specifications, as stated in the inquiry specification, data sheets, and order. The driver shall be
suitable for satisfactory operation under the utility and site conditions specified.
The driver shall be sized to accommodate specified process variations such as changes in pressure,
temperature, or properties of the liquid handled, as well as specified special plant start-up conditions.
Unless otherwise specified, for drive-train components that have a mass greater than 500 lb (225 kg),
the equipment feet shall be provided with vertical jackscrews.
Unless otherwise specified, electric motor drives shall conform to guidelines of 7.1.4.1 through 7.1.4.3,
or other standard as approved by the purchaser. The purchaser shall specify if IEC motors are required.
7.1.4.1 Low-voltage induction motors shall be in accordance with IEEE 841 [up to 500 hp (370 kW)].
7.1.4.2 General-purpose medium-voltage induction motors shall be in accordance with API 547 [250 hp
(186 kW) and larger].