PAGE NO. 1
****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= JUN 28, 2022 *
* Time= 13:37: 4 *
* *
* USER ID: *
****************************************************
1. STAAD SPACE
INPUT FILE: D:\Staad Files\Street Light With LT Cable.STD
2. START JOB INFORMATION
3. ENGINEER DATE 23-JUN-22
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 7.00001 0; 3 0 9.00002 0; 4 0.457001 7.00001 0
9. 5 -0.470001 7.00001 0
10. MEMBER INCIDENCES
11. 1 1 3; 2 5 2; 3 4 2
12. DEFINE MATERIAL START
13. ISOTROPIC STEEL
14. E 1.99947E+008
15. POISSON 0.3
16. DENSITY 76.8191
17. ALPHA 6.5E-006
18. DAMP 0.03
19. TYPE STEEL
20. STRENGTH FY 248210 FU 399894 RY 1.5 RT 1.2
21. END DEFINE MATERIAL
22. MEMBER PROPERTY AMERICAN
23. 1 PRIS OCT STA 0.13 END 0.07 THI 0.006
24. MEMBER PROPERTY INDIAN
25. 2 3 TABLE ST ISA50X50X4
26. CONSTANTS
27. MATERIAL STEEL ALL
28. SUPPORTS
29. 1 4 5 FIXED
30. MEMBER TENSION
31. 1 TO 3
32. DEFINE WIND LOAD
*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.
*** NOTE: MASS MODEL FORMED WILL BE USED IN SEISMIC/RESPONSE/TIME HISTORY LOADING, IF ANY.
IF MASS MODEL IS SEPARATELY PROVIDED IN INDIVIDUAL LOADING, THE GENERATED MASS
WILL BE REPLACED BY THE MASS PROVIDED IN INDIVIDUAL LOADING.
P R O B L E M S T A T I S T I C S
-----------------------------------
83. PARAMETER 2
84. CODE INDIAN
85. SELECT ALL
86. PARAMETER 3
87. CODE INDIAN
88. DJ1 1 ALL
89. DJ2 3 ALL
90. FYLD 250000 ALL
91. FINISH
****************************************************************************
**WARNING** SOME MEMBER SIZES HAVE CHANGED SINCE LAST ANALYSIS.
IN THE POST PROCESSOR, MEMBER QUERIES WILL USE THE LAST
ANALYSIS FORCES WITH THE UPDATED MEMBER SIZES.
TO CORRECT THIS INCONSISTENCY, PLEASE DO ONE MORE ANALYSIS.
FROM THE UPPER MENU, PRESS RESULTS, UPDATE PROPERTIES, THEN
FILE SAVE; THEN ANALYZE AGAIN WITHOUT THE GROUP OR SELECT
COMMANDS.
****************************************************************************
************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************