Certus CERTIFICATE OF CALIBRATION Metrology No : CE01342 Issue By PT. Certus Metrology Indonesia Date of Issue 21" November 2017 Page | of 5 Requested By: PT. National Andalan Services Job Order No. 2170491 Jalan Taman Cibalagung No. 06 Ambient Temperature: 22+ 3°C Pasir Jaya — Bogor Barat Relative Humidity +55 10% rh Kota Bogor 16610 Descriptions Instrument atinum resistance thermometer (PRT) with Precision Thermometer Brand ‘Accumae Model = AMI750-20 (PRT); AM8060 (Precision Thermometer) Serial No. 1620209 (PRT); PT4018130384 (Precision Thermometer) Immersion + Approx. 250 mm Calibration Range _ :-35°C to 500°C Date Calibrated [3 November 2017 to 21° Noveraber 2017 ‘Method of Calibration ‘The Platinum resistance thermometer (PRT) with Precision Thermometer has been calibrated at PT. Certus Metrology Indonesia under the ambient conditions stated above according to in-house calibration procedure STCP-005. The results of calibration reported traceable to SI units of measurement through NMC A*STAR ‘Singapore and LK-160-IDN. The Platinum resistance thermometer (PRT) with Precision Thermometer has been calibrated with prior annealing. The calibration was performed in terms of the International Temperature Scale of 1990 (ITS-90), Following precision thermometer setting applied during calibration: Channel 1, Sensor | setting: SPRT ‘The following reference standards were used during the calibration: i) Reference PRT Serial No : 1620616 ii) Reference Indicator Serial No : 3173/1 Results of Calibratio ‘The results of the calibration are shown in the next page(s). The expanded uncertainties on calibration result table (include the uncertainty at intermediate temperature) estimated at a confidence level of approximately 95% with a coverage factor of k= 2. iscericate mo ot be reproaced other than inl ep with rir weten ppl of Crus Metoy Indonesia Certus CERTIFICATE OF CALIBRATION Metrology No : CE01342 Platinum resistance thermometer with indicator Serial Number: 1620209; PT4018130384 Page 2 of 5 100.0382 160.9716 189.0846 257.2267 284.7460, 100.0382 ‘The resuls reported rola have boon performed in acoardance withthe Tboratorys tems of accrediation under the Komita Akreitasi Nasional ~ LK-1604DN", ‘The calibration coefficients, calculated in accordance with ITS-90 and used in the computation ‘Program and precision thermometer are as follow: Value below 273.19K (0°C): Value above 273.15K (0°C): Av -0.507 033 E-03 A= -0.638 534 E-03 B=-0.114 581 B02 B=-0.191 315 E-04 C= 1.158 035 E-05 Tis ceticate ny ot be erodced cer than nfl excep with prior written approval ofertas Metoogy Indonesia Certus Metrology nee W(T90) (90) 0.86 34.916 0.87 32.434 0.88 -29.950 0.89 -27.464 090 24.975 091 -22.487 0.92 19.995 oss -17501 0.94 ~15.005, 0.95 -12.508, 0.96 ~10.008, 097 -7,507 0.98 5.003 0.99 2.497 1.00 0.010 CERTIFICATE OF CALIBRATION No ; CE01342 Platinum resistance thermometer with indicator Serial Number: 1620209; PT4018130384 Page 3 of 5 iiscerticate may ot be reproduced ther than ial exept with prior writen ppoval of Certs Metogy Indonesia Certus CERTIFICATE OF CALIBRATION Metrology No : CE01342 Platinum resistance thermometer with indicator Serial Number: 1620209; PT4018130384 Page 4 of 5 Positive range wcT90) (90) WCT90)(90)—W(T90) 690) W(T90) 190) 100 0.010 12665898 = 1.52 133.147 1.78 201.825 101 2.520 127 68.459 153 135.761 1.79 204.496 1.02 5.031 1.28 71.022 154 138.378 1.80 207.169 103 7.545 129° 73587 «1.55 140,997 181 209.845 104 10.061 130 76.154 1.56 143.618 1.82, 212.522 10512578 = «13178.723« 1.57 (146.241 1.83 215.202 . 106 15.098 «1.32 81.294 158 148.866 1.84 217.885 10717619 1.3383.867 159 151.493 18s 220.569 108 20.142 1.34 (86.442 160 154.123, 1.86 223.256 1 1.09 22.668 135 89.019 1.61 156.754 1.87 225.945 110 25.195 136 91.598 1.62 159.388, 1.88 228.636 LIL 27.724 137 94.180 1.63, 162.024 1.89 231.330 112 30.255 1.38 (96.763 164 164.662 1.90 234.025 1.13 32.788 «1.39 99.348 165 167302191 236.723 11435323 «140101936 1.66 169.945 192 239.424 115 37.860 «© 141.—«*108.5251.67 172.589 1.93 242.127 116 40399 «142 «107.117 1.68 175.236 1.94 244.831 117 42.940 143,109,710 1.69 17.885 1.95, 247.539 118 45483 144112306 1.70 180836 1.96 250,248 119 48.028 «1451149047 183.190 1.97 252.960 120 50575 146 117,503 72 .85.845 1.98 255.674 121 53124147 120.105 1.73 188.503 1.99 258.391 122 55675 «148122709 1.74 191.163 2.00 261.110 123 58.228 «= 149.125.316.175 (193.825 2.01 263.831 124 60.782 «1.50 127.924 1.76 196.489 2.02 266.554 | 125 63339 «LSI 130.534 1.77 199.156 2.03 269,280 Rudianto Signatory To seseeeie Exotic ae ees Thiscertfeate may nat be repraduced ther thar nfl except wit rior written approval of Cetus Metolgy indonesia Certus CERTIFICATE OF CALIBRATION | Metrology No : CE01342 | Platinum resistance thermometer with indicator Serial Number: 1620209; PT4018130384 Page 5 of 5 Positive range W(T90)1(90)_—W(T90)_ (90) WCT90) (90) W(T90) (90) 2.04 272.009 -2.30343.785 2:56 417.262 2.82 492.587 205 274.739 «231 346.578 «2.57 420.128 2.83 495.523 2006 «277472 «—«232 349.375 2.58 422.989 BA 498.463 2.07 280.207 «233352174 «2.59 «425.856 2.85 501.405 2.08 282.945 «2.34 «354.975 2.60 428.726 2.09 285.685 «2.35 357.779 2.61 «431.599 210 288427 2.36 360.585 2.62 434.475 241 291472237 363.394 2.63 437.353 242 293.919 «2.38 366.206 2.64 «440.235 213 296.669 2.39 369.020 2.65 443.119 214 299.421 «2.40 371.837 2.66 446,006 245 302.175 2.41 374.656 «2.67 448.895 246 304.932 242377478 «2.68 451.788 2.47 307.691 243. —««380.303.2.69 454.683 218 310453 «244 383.130 2.70 457.581 219 313217 2.45 385.960 2.71 460.482 2.20 315.984 2.46 388.792 2.72 (463.386 221 318.753 2.47 391,627 «2.73 466.293 222 321.524 248394465 2.74 469.203 223 324298 «© 2.49 397305 2.75 472.116 224 327074 2.50 400.148 «2.76 475.031 225 329853251 -402.994 «2.77 «477.950 2.26 332.634 «2.52 405.842 2.78 480.871 227 335418 2.53 408.693 2.79 483.796 228 338.204 2.54 411.547 2.80 486.723 229 340.993 «2.55 414.403 2.81 (489.653 ‘This certifcae my tbe reproduced cter than in llxcep wit pir writen approval of Cetus Metloy ndaesia .

You might also like