You are on page 1of 52

® ®

DIRECT CURRENT MOTORS


Code DOC00053 - Rev. 06

Technical Catalogue
January
2018

web edition

Dana Brevini S.p.A.


Via Luciano Brevini 1/a
42124 Reggio Emilia
Tel. +39 0522 270711
Fax +39 0522 270660
www.dana.com/brevini
info@brevinifluidpower.com
Index
®

DC motors

Description Type Page


Introducion 2
12V DC - 0.35 kW - D.80 25021400 4
24V DC - 0.4 kW - D.80 25021500 6
12V DC - 0.5 kW - D.80 25024200 8
24V DC - 0.5 kW - D.80 25024300 10
12V DC - 0.7 kW - D.80 25021600 12
24V DC - 0.8 kW - D.80 25021700 14
12V DC - 0.8 kW - D.80 25021800 16
24V DC - 0.8 kW - D.80 25021900 18
12V DC - 1.6 kW - D.115 25021100 20
24V DC - 2.2 kW - D.115 25021200 22
12V DC - 1.5 kW - D.115 25022200 24
12V DC - 1.5 kW - D.115 25022200 FAN 26
24V DC - 2.0 kW - D.115 25022300 28
24V DC - 2.0 kW - D.115 25022300 FAN 30
12V DC - 1.6 kW - D.115 25022000 32
24V DC - 2.2 kW - D.115 25022100 34
12V DC - 1,6 kW - D.115 25022600 36
24V DC - 2,2 kW - D.115 25022700 38
24V DC - 3.0 kW - D.125 25021300 40
24V DC - 3.0 kW - D.125 25021300 FAN 42
24V DC - 3.0 kW - D.125 25022400 44
24V DC - 3.0 kW - D.125 25022400 FAN 46
Starting switch 120A 48
Starting switch 150A 48

© 2018 Dana Brevini S.p.A. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics, VPS Brevini, OT Oiltechnology, logos are
trademarks or are registered trademarks of Dana Brevini S.p.A. or other companies Dana in Italy and other countries.
The technical features supplied in this catalogue are non binding and no legal action can be taken against such material. Dana Brevini will not be held responsi-
ble for information and specifications which may lead to error or incorrect interpretations. Given the continuous technical research aimed at improved technical
features of our products, Dana Brevini reserves the right to make change that are considered appropriate without any prior notice. This catalogue cannot be
reproduced (in while or in part) without the prior written consent of Dana Brevini. This catalogue supersedes all previous ones.
Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The type of application and operating condi-
tions must be assessed as normal or in malfunction in order to avoid endangering the safety of people and/or items.

IE/INDEX/02-2013 1
Introduction
®

This collection of technical tables lists all the DC motors approved by Dana Intermittent periodic duty – Duty type S3
Brevini and used in power units of its standard production. Dana Brevini of- A sequence of identical duty cycles, each including a period of operation at
fers a wide range of DC motors with rated voltage from 12 V to 24 V and constant load and a rest and de-energized period. The duration of a cycle is
power from 350 W to 3000 W. The diagrams shown are determined from tests generally 10 min. The value S3 is expressed as a percentage For example S3=
performed with the characteristics specified in the same technical tables” 25% means that the load on the motor can be constant for 25% of cycle time
and using the standard power units manufactured by Dana Brevini. (2.5 minutes); then you need a rest position for the remaining 75 % of cycle
The curves thus show the performances of the power unit in relation to the time (7.5 minutes) before starting over a new cycle.
pump installed. One table describes the main characteristics of the pumps
specifying their size (group) Protection degree
The degree of protection is indicated in accordance with standard EN 60034-
Motor typology 5 corresponding to CEI 2-16. The codes to indicate degree of protection are
The two main types of DC motors used by Dana Brevini are: made by the letters IP followed by two characteristics numerals.
• With permanent magnets, generally low power motors, reversible, in
The protection degree are valid in many cases only for motors assembled on
which the magnetic field is generated by permanet magnets and excita-
power units or other products manufactured by Dana Brevini.
tion is constant;
• With wound fields: generally medium power, unidirectional, where both
Insulation class
excitation and armature windings are electrically driven. These are then
The insulation class indicated is in accordance with standard EN correspond-
divided into two other families: series coonection and compound.
ing to CEI 15-26. It indicates the maximum appropriate temperature for the
product in nominal operating conditions, without damages to the insulating
material of the motor.
Permanent Wound fields Insulation class Y A E B F H
magnets Series Compound
Temperature (°C) 90 105 120 130 155 180

M M
How to choice the motor
M Each motor has its own characteristic curve. The main specifications are: flow
rate (in l/min or US gpm), pressure (in bar or psi), current (in Ampere) and duty
type S2 (in minutes) or S3 (in percentage of working time).
A2+ A1- D1E1+ A2E2- D1E1+ A2E2-
Reference data
Reversible Unidirectional Unidirectional • Maximum nominal pressure Pmax = 290 Bar (4206 psi)
(nominal left) left left • Oil ISO VG32 at temperature 35°C (viscosity 40 cSt)
• Outside temperature 25°C
Duty cycle • Maximum nominal current Imax = 300A
In order to ensure the correct choice of the motor, must be known the type • Constant stabilized voltage detected at the terminals of the electric motor.
of duty cycle required by the application and it has to be compared with the
motor features. As a function of pressure and pump displacement, determines the flow rate,
Duty types S1, S2, S3 are defined according to standards EN 60034-1, cor- drawing a vertical line from the pressure value, intercepting the curve relat-
responding to CEI 2-3. ing the pump, in fact you can read the flow rate on the ordinate. For example:
pressure 100 bar (1450 psi), pump 3.8 cm³/rev (0.23 in³/rev), you have a flow
Definitions rate of 10 l/min (2.6 US gpm).
Duty type
A continuous, short time or periodic duty, comprising one or more loads re- US
gpm
l/min
24
maining constant for the duration specified, or a non-periodic duty in which 6.0
generally load and speed vary within the permissible operating range. 22
5.5
20
Thermal equilibrium 5.0
The state reached when the temperature rises of the several parts of the 18
machine do not vary by more than 2°C over a period of 1 h. 4.5
16
78
4.0
Cyclic duration factor 14 63
The ratio between the period of loading, including starting and electric brak- 3.5
60
ing, and the duration of the duty cycle, expressed as a percentage. 3.0
12

10 10 48
Continuous running duty – Duty type S1 l/min 2.5 43
Operation at constant load of sufficient duration for thermal equilibrium to 2.0
8 38
be reached. 32
6
1.5 26
22 17
Short time duty – Duty type S2 1.0 4 20
Operation at constant load during a given time, less than that required to
reach thermal equilibrium, followed by a rest and de-energized period of suf- 0.5 2 12 15

ficient duration to re-establish initial conditions 0 0


0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/INTRO/02-2017 2
Introduction
®

Similarly you can read the value of current absorption in the related diagram. Example of installation
With the same data of the previous example you have a current consumption The following i san example of electrical connection
of 217 A.
Amp
78 63 60 48 43 38 32 26 22 20
300 Switch ON/OFF
280 Start switch
17
260 15
240 12 Connection without
217 220 thermal switch
A Connection for
200
thermal switch
180
Thermal switch
160
(optional)
140

120

100

80

60
Battery
40

20

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Taking again the current consumption on the S2-S3 diagram, you have a S2 duty equal All electrical connections and disconnections must be performed by trained,
to 1.55 ( 1’32’’) minutes and a S3 duty equal to 5.1 % (30 s on a cycle of 10 minutes). specialized personnel.
S2 (min) S3 (%)
20 40 When wiring a motor, it is important to consider the cross-sectional area
18 36 and length of the power cables. Cables with overly small cross-sections and
16 32 overly long lengths may cause voltage drops that could prevent the PU from
14 28
operating properly.
12 24

10 20
Use these tightening torque values on the motor terminals and the start
8 16
switch.
S3
6 12
ISO M8 5 ÷ 7 Nm [3.69 ÷ 5.16 lbf · ft]
4 8
ISO M6 3 ÷ 5 Nm [2.21 ÷ 3.69 lbf · ft]
S2
1.55 2 4
5.1 %
min
0
30 40 50 60 70 80
0
90 100 110 120 130 140 150 160 180 200 220 240 260 280 Amp
5/16-18 UNC-2A 5 ÷ 7 Nm [3.69 ÷ 5.16 lbf · ft]

Unit of measure conversion


Quantity Unit Symbol Other units Symbol Equivalence Reverse Equivalence
US Gallon /minutes US gal/min 1 US gal/min=3.7848 l/min 1 l/min = 0. 2642 US gal/min
Liters at
Flow rate l/min UK Gallon /minutes Imp gal/min 1 Imp gal/min=4.5456 l/min 1 l/min = 0.2199 Imp gal/min
minutes
Cubic feet /minutes cu ft/min 1 cu ft/min= 28.32 l/min 1 l/min = 0.0353 cu ft/min
Pascal Pa 1 Pa= 10-5 bar 1 bar= 105 Pa
Atmosphere Atm 1 atm = 1.0132 bar 1 bar= 0.9869 atm
Pressure bar bar
Kilogram force on cm² kgf /cm² 1 kgf /cm² = 0.9806 bar 1 bar= 1.0197 kgf/cm²
Pound force on in² lbf/in² or psi 1 psi = 0.068948 bar 1 bar= 14.5038 psi

Main formulae
Flow rate from pump Q[l/min] = V[cm³/rev] · n[rpm] · ηvol · 10 -3 V = displacement (cm³/rev)
Q = flow rate (l/min)
V[cm³/rev] · ΔP [bar] T = torque (Nm)
Torque absorbed by pump T[Nm] = N = power (kW)
20p · ηmecc
n = speed (rpm)
ΔP = pressure difference between
2p · 10 -3 · T[Nm] · n[rpm] Q[l/min] · ΔP [bar] inlet and outlet (bar)
Power absorbed by pump N[kW] = = ηmecc = mechanical efficiency
60 600 · ηtot
ηvol = volumetric efficiency
ηtot = total efficiency
Total efficiency ηtot = ηmecc · ηvol

IE/INTRO/02-2017 3
25021400
®

12 VDC - 0.35 KW - D.80 MOTOR


6.5 [0.26]

3 [0.12]
Ø7 [0.28]

6.5 [0.26]
Ø76 [2.99]

M6
Ø80 [3.15]

101 [3.98]
50 [1.97]
Ø14.9 [0.59]

6.4 [0.25]

13.5 [0.53] 15.5 [0.73]


88 [3.46]
mm [inches]
143.5 [5.65]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size)


Power 0.35 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.2 kg [4.85 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.0

1.25
4.5

4.0
1.00
12
3.5

3.0 09
0.75

2.5
07
2.0
0.50
05
1.5

04
0.25 1.0
02

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021400/01-2012 4
25021400
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
90

85
12 09 07 05 04
80

75

70

65

60
02
55

50

45

40

35

30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
18 54
17 51
16 48
15 45
14 42
13 39
12 36
11 33
10 30
S3
9 27
S2
8 24
7 21
6 18
5 15
4 12
3 9
2 6
1 3
0 0
25 30 35 40 45 50 55 60 65 70 75 80 85 Amp

ORDERING CODE

Code Description Code Description


25021400 12VDC motor - 0.35 kW KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 80A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021400/01-2012 5
25021500
®

24 VDC - 0.4 KW - D.80 MOTOR


6.5 [0.26]

3 [0.12]
Ø7 [0.28]

6.5 [0.26]
Ø76 [2.99]

M6
Ø80 [3.15]

101 [3.98]
50 [1.97]
Ø14.9 [0.59]

6.4 [0.25]

13.5 [0.53] 15.5 [0.73] mm [inches]


88 [3.46]
143.5 [5.65]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size)


Power 0.4 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.2 kg [4.85 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.0

1.25
4.5

4.0
1.00

3.5
12

3.0
09
0.75

2.5

07
2.0
0.50

05
1.5

04
0.25 1.0 02

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021500/00-2012 6
25021500
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
55

12 09 07 05
50

04
45

40

35
02
30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 60

18 54

16 48

14 42
S3
12 36
S2
10 30

8 24

6 18

4 12

2 6

0 0
5 10 15 20 25 30 35 40 45 50 55 Amp

ORDERING CODE

Code Description Code Description


25021500 24VDC motor - 0.4 kW KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 50A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021500/00-2012 7
25024200
®

12 VDC - 0.5 KW - D.80 MOTOR

6.5 [0.26]

3 [0.12] 101 [3.98]

M6
6.5 [0.26]
Ø 78 [3.07]

88 [3.46]
Ø80 [3.15]

32,4 [1.28]
Ø14.9 [0.59]

6.4 [0.25]

Ø7.2
[0.28]

19 [0.75]

13.5 [0.53] 154,9 [6.1] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size)


Power 0.5 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.5 kg [5.51 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.0

1.25
4.5

4.0
1.00
12
3.5

3.0 09
0.75

2.5
07
2.0
0.50
05
1.5

04
0.25 1.0
02

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25024200/01-2013 8
25024200
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
90

85
12 09 07 05 04
80

75

70

65

60
02
55

50

45

40

35

30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
18 54
17 51
16 48
15 45
14 42
13 39
12 36
11 33
10 30
S3
9 27
S2
8 24
7 21
6 18
5 15
4 12
3 9
2 6
1 3
0 0
25 30 35 40 45 50 55 60 65 70 75 80 85 Amp

ORDERING CODE

Code Description Code Description


25024200 12VDC motor - 0.35 kW KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 80A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25024200/01-2013 9
25024300
®

24 VDC - 0.5 KW - D.80 MOTOR

6.5 [0.26]

3 [0.12] 101 [3.98]

M6
6.5 [0.26]
Ø 78 [3.07]

88 [3.46]
Ø80 [3.15]

32,4 [1.28]
Ø14.9 [0.59]

6.4 [0.25]

Ø7.2
[0.28]

19 [0.75]

13.5 [0.53] 154,9 [6.1] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size)


Power 0.5 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.5 kg [5.51 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.0

1.25
4.5

4.0
1.00

3.5
12

3.0
09
0.75

2.5

07
2.0
0.50

05
1.5

04
0.25 1.0 02

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25024300/01-2013 10
25024300
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
55

12 09 07 05
50

04
45

40

35
02
30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 60

18 54

16 48

14 42
S3
12 36
S2
10 30

8 24

6 18

4 12

2 6

0 0
5 10 15 20 25 30 35 40 45 50 55 Amp

ORDERING CODE

Code Description Code Description


25024300 24VDC motor - 0.5 kW KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 50A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25024300/01-2013 11
25021600
®

12 VDC - 0.7 KW - D.80 MOTOR


6.5 [0.26]

3 [0.12]
Ø7 [0.28]

M
6
6.5 [0.26]

Ø76 [2.99]

101 [3.98]
Ø80 [3.15]

Ø14.9 [0.59]

6.4 [0.25]

13.5 [0.53] 115 [4.53]


mm [inches]
88 [3.46]
162 [6.38]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size)


Power 0.7 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.7 kg [5.95 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.5

5.0
1.25
4.5

4.0
1.00
12
3.5

09
3.0
0.75
07
2.5

05
2.0
0.50

04
1.5

02
0.25 1.0

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021600/00-2012 12
25021600
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
150
12 09 07 05
140

130

120

110
04

100

90

80
02
70

60

50

40

30

20

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
15 45
14 42
13 39
S2
12 36
11 33
10 30
9 27
S3
8 24
7 21
6 18
5 15
4 12
3 9
2 6
1 3
0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Amp

ORDERING CODE

Code Description Code Description


25021600 12VDC motor - 0.7 kW KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021600/00-2012 13
25021700
®

24 VDC - 0.8 KW - D.80 MOTOR


6.5 [0.26]

3 [0.12]
Ø7 [0.28]

M
6
6.5 [0.26]

Ø76 [2.99]

101 [3.98]
Ø80 [3.15]

Ø14.9 [0.59]

6.4 [0.25]

13.5 [0.53] 115 [4.53]


mm [inches]
88 [3.46]
162 [6.38]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size)


Power 0.8 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.7 kg [5.95 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.5

5.0
1.25
4.5

4.0
1.00
12
3.5

09
3.0
0.75

2.5
07

2.0
0.50
05
1.5
04
02
0.25 1.0

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021700/00-2012 14
25021700
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
90

85
12 09 07
80

75 05
70

65

60 04
55

50

45
02
40

35

30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
13 39

12 36
S2
11 33

10 30

9 27
S3
8 24

7 21

6 18

5 15

4 12

3 9

2 6

1 3

0 0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Amp

ORDERING CODE

Code Description Code Description


25021700 24VDC motor - 0.8 kW KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 80A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021700/00-2012 15
25021800
®

12 VDC - 0.8 KW - D.80 MOTOR

6.5 [0.26]

3 [0.12] 101 [3.98]

M6
6.5 [0.26]
Ø 78 [3.07]

88 [3.46]
Ø80 [3.15]

32,4 [1.28]
Ø14.9 [0.59]

6.4 [0.25]

Ø7.2
[0.28]

19 [0.75]

13.5 [0.53] 154,9 [6.1] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size)


Power 0.8 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.5 kg [5.51 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.5

5.0
1.25
4.5

4.0
1.00
12
3.5

09
3.0
0.75
07
2.5

05
2.0
0.50

04
1.5

02
0.25 1.0

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021800/02-2013 16
25021800
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
150
12 09 07 05
140

130

120

110
04

100

90

80
02
70

60

50

40

30

20

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
15 45
14 42
13 39
S2
12 36
11 33
10 30
9 27
S3
8 24
7 21
6 18
5 15
4 12
3 9
2 6
1 3
0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Amp

ORDERING CODE

Code Description Code Description


25021800 12VDC motor - 0.8 kW KIT07012.027 Starting switch kit 12VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021800/02-2013 17
25021900
®

24 VDC - 0.8 KW - D.80 MOTOR

6.5 [0.26]

3 [0.12] 101 [3.98]

M6
6.5 [0.26]
Ø 78 [3.07]

88 [3.46]
Ø80 [3.15]

32,4 [1.28]
Ø14.9 [0.59]

6.4 [0.25]

Ø7.2
[0.28]

19 [0.75]

13.5 [0.53] 154,9 [6.1] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size)


Power 0.8 kW 02 0.25 05
Nominal diameter 80 mm [3.15 in] 04 0.45 05
Permanent 05 0.56 05
Motor type
magnet 07 0.75 05/1
Rotation CCW-CW 09 0.9 05/1
Protection class IP 12 1.2 05/1
54
(with motor assembled on hydraulic power pack)
S2 / S3 duty service see curves
Insulation class F
Weight 2.5 kg [5.51 lb]

Performance with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]
US l/min
gpm 5.5

5.0
1.25
4.5

4.0
1.00
12
3.5

09
3.0
0.75

2.5
07

2.0
0.50
05
1.5
04
02
0.25 1.0

0.5

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

IE/25021900/02-2013 18
25021900
®

Current with GR05 / GR1 pumps


Displacement 0.2 ÷ 1.2 cc/rev [0.012 ÷ 0.073 in³/rev]

Amp
90

85
12 09 07
80

75 05
70

65

60 04
55

50

45
02
40

35

30

25

20

15

10

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
13 39

12 36
S2
11 33

10 30

9 27
S3
8 24

7 21

6 18

5 15

4 12

3 9

2 6

1 3

0 0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Amp

ORDERING CODE

Code Description Code Description


25021900 24VDC motor - 0.8 kW KIT07012.032 Starting switch kit 24VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 80A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021900/02-2013 19
25021100
®

12 VDC - 1.6 KW - D.115 MOTOR

9.1 [0.36] max 133 [5.24]


Ø15 [0.59]

M8
M5 n°2
6.4 [0.25]

D1E1
Ø114 [4.49]

90.4 [3.56]
Ø35 [1.38]

A2E2 1/4-20UNC
11 [0.43] max
Ø98.3 [3.87]
mm [inches]
12.3 [0.48] max 158 [6.22]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 1.6 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
78
4.0
3.0
0.75 10 14 63
3.5
09 60
2.5 12
3.0
07
10 48
2.0 2.5
0.50 43
05
8 38
2.0
1.5 04 32
6
1.5 26
02
0.25 1.0 22 17
4 20
1.0

0.5
0.5 2 12 15

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25021100/00-2012 20
25021100
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26 22 20
200 300

10 280
180 17
260 15
09
160 240 12
220
07
140
200

120 05 180

160
04
100
140

80 02 120

100
60
80

40 60

40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20
Motor with thermal switch
8 16

S3
6 12

4 8
S2
2 4

0 0
30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280 Amp

ORDERING CODE

Code Description Code Description


25021100 12VDC motor - 1.6 kW KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)
25016600 12VDC motor - 1.6 kW with thermal switch
90340008 Thermal switch

Reference data: maximum nominal pressure Pmax = 250 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 140A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021100/00-2012 21
25021200
®

24 VDC - 2.2 KW - D.115 MOTOR

9.1 [0.36] max 133 [5.24]


Ø15 [0.59]

M8
M5 n°2
6.4 [0.25]

D1E1
Ø114 [4.49]

90.4 [3.56]
Ø35 [1.38]

A2E2
1/4-20UNC
11 [0.43] max
Ø98.3 [3.87]

12.3 [0.48] max 158 [6.22] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 2.2 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
4.0 78
3.0 10 14
0.75
3.5
09 63
2.5 12
07 3.0
60
10
2.0 2.5 48
0.50 05
8
43
2.0
1.5 04 38
6 32 26
1.5
02 22
0.25 1.0
20
1.0 4
17
15
0.5
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25021200/00-2012 22
25021200
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26
100 200

90 10 180 22

09 20
80 160

07 17
70 140
15
60 05 120
12

50
04 100

02
40 80

30 60

20 40

10 20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20
S3 Motor with thermal switch
8 16
S2
6 12

4 8

2 4

0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Amp

ORDERING CODE

Code Description Code Description


25021200 24VDC motor - 2.2 kW KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)
25016700 24VDC motor - 2.2 kW with thermal switch
90340008 Thermal switch

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021200/00-2012 23
25022200
®

12 VDC- 1.5 KW - D.115 MOTOR

8.5 [0.33] 111 [4.37]

Ø 5.5 N° 6

M8
[0.22]
Ø15 [0.59]

6.4 [0.25]
Ø112 [4.41]

90.5 [3.56]
Ø35 [1.38]

1/4-20UNC

6.4 [0.25]
Ø98.35 [3.87]
12 [0.47] 173 [6.81] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 1.5 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0,9 05/1 43 4.3 1
Protection class IP 10 1,0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1,2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1,5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
78
4.0
3.0
0.75 10 14 63
3.5
09 60
2.5 12
3.0
07
10 48
2.0 2.5
0.50 43
05
8 38
2.0
1.5 04 32
6
1.5 26
02
0.25 1.0 22 17
4 20
1.0

0.5
0.5 2 12 15

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022200/00-2012 24
25022200
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26 22 20
200 300

10 280
180 17
260 15
09
160 240 12
220
07
140
200

120 05 180

160
04
100
140

80 02 120

100
60
80

40 60

40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20

8 16

S3
6 12

4 8
S2
2 4

0 0
30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280 Amp

ORDERING CODE

Code Description Code Description


 25022200 12VDC motor - 1.5 kW KIT07012.033 Starting switch kit 12VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022200/00-2012 25
25022200 FAN
®

12 VDC - 1.5 KW - D.115 MOTOR


157 [6.18]

M8 Ø 5.5 [0.22] N.6


Ø35 [1.38]

Ø14,8 [0.58]

5 [0.2]

Ø112 [4.41]

Ø 116,6 [4.59]

118 [4.65]

132 [5.2]
M8
X 46 [1.81] 173 [6.81] Ø 110 [4.33]

219 [8.62] 118 [4.65]


132 [5.2]
mm [inches]
X = see ordering code

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 1.5 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0,9 05/1 43 4.3 1
Protection class IP 10 1,0 05/1 48 4.8 1
10
(with motor assembled on hydraulic power pack) 12 1,2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1,5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 7.4 kg [16.31 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
78
4.0
3.0
0.75 10 14 63
3.5
09 60
2.5 12
3.0
07
10 48
2.0 2.5
0.50 43
05
8 38
2.0
1.5 04 32
6
1.5 26
02
0.25 1.0 22 17
4 20
1.0

0.5
0.5 2 12 15

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022200 FAN/02-2014 26
25022200 FAN
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26 22 20
200 300

10 280
180 17
260 15
09
160 240 12
220
07
140
200

120 05 180

160
04
100
140

80 02 120

100
60
80

40 60

40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
44 40

40 44

36 36

32 32

28 28
Motor with thermal switch
24 24

20 20

16 16

12 12
S3
8 8
S2
4 4

0 0
110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 Amp

ORDERING CODE

Code Code Description


Power Code Fan cooled Code
X KIT07012.033 Starting switch kit 12VDC - 120A (fixing with clamp)
Fan cooled motor Fan cooled
pack mm [inch]
motor with thermal kit
swich
FP 52.6 [2.07] KIT09008.061 KIT09008.062 25017800
MC 41.6 [1.64] KIT01008.065 KIT01008.088 25002300

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022200 FAN/02-2014 27
25022300
®

24 VDC - 2.0 KW - D.115 MOTOR

8.5 [0.33] 111 [4.37]

Ø 5.5 N° 6

M8
[0.22]
Ø15 [0.59]

6.4 [0.25]
Ø112 [4.41]

90.5 [3.56]
Ø35 [1.38]

1/4-20UNC

6.4 [0.25]
Ø98.35 [3.87]
12 [0.47] 173 [6.81] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 2.0 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
4.0 78
3.0 10 14
0.75
3.5
09 63
2.5 12
07 3.0
60
10
2.0 2.5 48
0.50 05
8
43
2.0
1.5 04 38
6 32 26
1.5
02 22
0.25 1.0
20
1.0 4
17
15
0.5
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022300/00-2012 28
25022300
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26
100 200

90 10 180 22

09 20
80 160

07 17
70 140
15
60 05 120
12

50
04 100

02
40 80

30 60

20 40

10 20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20
S3
8 16
S2
6 12

4 8

2 4

0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Amp

ORDERING CODE

Code Description Code Description


25022300 24VDC motor - 2.0 kW KIT07012.034 Starting switch kit 24VDC - 120A (fixing with clamp)

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022300/00-2012 29
25022300 FAN
®

24 VDC - 2.0 KW - D.115 MOTOR

157 [6.18]

M8 Ø 5.5 [0.22] N.6


Ø35 [1.38]

Ø14,8 [0.58]

5 [0.2]

Ø112 [4.41]

Ø 116,6 [4.59]

118 [4.65]

132 [5.2]
M8
X 46 [1.81] 173 [6.81] Ø 110 [4.33]

219 [8.62] 118 [4.65]


132 [5.2]
mm [inches]
X = see ordering code

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 2.0 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
10
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 7.4 kg [16.31 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
4.0 78
3.0 10 14
0.75
3.5
09 63
2.5 12
07 3.0
60
10
2.0 2.5 48
0.50 05
8
43
2.0
1.5 04 38
6 32 26
1.5
02 22
0.25 1.0
20
1.0 4
17
15
0.5
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022300 FAN/02-2014 30
25022300 FAN
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26
100 200

90 10 180 22

09 20
80 160

07 17
70 140
15
60 05 120
12

50
04 100

02
40 80

30 60

20 40

10 20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
44 44

40 40

36 36

32 32
Motor with thermal switch
28 28

24 24

20 20

16 16
S3
12 12

S2
8 8

4 4

0 0
40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Amp

ORDERING CODE

Code Code Description


Power Code Fan cooled Code
X KIT07012.034 Starting switch kit 24VDC - 120A (fixing with clamp)
Fan cooled motor Fan cooled
pack mm [inch]
motor with thermal kit
swich
FP 52.6 [2.07] KIT09008.031 KIT09008.063 25017800
MC 41.6 [1.64] KIT01008.067 KIT01008.077 25002300

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022300 FAN/02-2014 31
25022000
®

12 VDC - 1.6 KW - D.115 MOTOR

8.4 [0.33] 115 [4.53]


Ø15 [0.59]

M5 n°2
6.43 [0.25]

M8
Ø112 [4.41]
Ø35 [1.38]

90 [3.54]
11 [0.43] 1/4-20UNC
11.8 [0.46] 173 [6.81] Ø98.35 [3.87] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 1.6 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
78
4.0
3.0
0.75 10 14 63
3.5
09 60
2.5 12
3.0
07
10 48
2.0 2.5
0.50 43
05
8 38
2.0
1.5 04 32
6
1.5 26
02
0.25 1.0 22 17
4 20
1.0

0.5
0.5 2 12 15

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022000/00-2012 32
25022000
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26 22 20
200 300

10 280
180 17
260 15
09
160 240 12
220
07
140
200

120 05 180

160
04
100
140

80 02 120

100
60
80

40 60

40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20

8 16

S3
6 12

4 8
S2
2 4

0 0
30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280 Amp

ORDERING CODE

Code Description Code Description


 25022000 24VDC motor - 1.6 kW KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022000/00-2012 33
25022100
®

24 VDC - 2.2 KW - D.115 MOTOR

8.4 [0.33] 115 [4.53]


Ø15 [0.59]

M5 n°2
6.43 [0.25]

M8
Ø112 [4.41]
Ø35 [1.38]

90 [3.54]
11 [0.43] 1/4-20UNC
11.8 [0.46] 173 [6.81] Ø98.35 [3.87] mm [inches]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 2.2 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Wound field 05 0.56 05 32 3.2 1
Motor type
compound 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1 63 6.3 1
Insulation class F 17 1.7 1 78 7.8 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 5.0 gpm 24

1.25 6.0
22
4.5
5.5
20
4.0 5.0
1.00 18
3.5 4.5
16
4.0 78
3.0 10 14
0.75
3.5
09 63
2.5 12
07 3.0
60
10
2.0 2.5 48
0.50 05
8
43
2.0
1.5 04 38
6 32 26
1.5
02 22
0.25 1.0
20
1.0 4
17
15
0.5
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022100/00-2012 34
25022100
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 7.8 cc/rev [0.073 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32 26
100 200

90 10 180 22

09 20
80 160

07 17
70 140
15
60 05 120
12

50
04 100

02
40 80

30 60

20 40

10 20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20
S3
8 16
S2
6 12

4 8

2 4

0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Amp

ORDERING CODE

Code Description Code Description


 25022100 24VDC motor - 2.2 kW KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022100/00-2012 35
25022600
®

12 VDC - 1.6 KW - D.115 MOTOR

5-1
6-1
8.4 [0.33] 121.2 [4.77]

8U
NC
-2A
M5 n°2
Ø15 [0.59]
6.43 [0.25]
Ø35 [1.38]
Ø114.3 [4.5]

90.4 [3.56]
1/4-20UNC
9.1 [0.36] mm [inches]
11.8 [0.46] 161.8 [6.37] Ø98.32 [3.87]

RATED FEATURES PUMP TYPE

Voltage 12 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 1.6 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Serie “U” 05 0.56 05 32 3.2 1
Motor type
(USA) 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1
Insulation class F 17 1.7 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]
US l/min US l/min
gpm 8.0 gpm 22

2.00 5.5
20
7.0
5.0
1.75 18
4.5
6.0 10
16
1.50
4.0
09
5.0 14
1.25 3.5
07
12
3.0
4.0 05
1.00 60
10
2.5

3.0 04 48
0.75 8
2.0 43
38
02 6 32
2.0 1.5
0.50 26
22 20
1.0 4
17
0.25 1.0 15
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022600/00-2012 36
25022600
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

Amp Amp
60 48 43 38 32 26 22
220 300

10 20
280
200 17
09 15
260
180 12
07 240

160 220
05
200
140 04
180

120 02 160

140
100

120
80
100

60 80

60
40
40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24
S3
10
S2
20
Motor with thermal switch
8 16

6 12

4 8

2 4

0 0
30 40 50 60 70 80 90 100 110 120 130 140 150 160 180 200 220 240 260 280 Amp

ORDERING CODE

Code Description Code Description


25022600 12VDC motor - 1.6 kW KIT07012.025 Starting switch kit 12VDC - 120A (fixing with screws)
25022800 12VDC motor - 1.6 kW with thermal swich

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 12 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022600/00-2012 37
25022700
®

24 VDC- 2.2 KW - D.115 MOTOR

5-1
6-1
8.4 [0.33] 121.2 [4.77]

8U
NC
-2A
M5 n°2
Ø15 [0.59]
6.43 [0.25]
Ø35 [1.38]
Ø114.3 [4.5]

90.4 [3.56]
1/4-20UNC
9.1 [0.36] mm [inches]
11.8 [0.46] 161.8 [6.37] Ø98.32 [3.87]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 2.2 kW 02 0.25 05 22 2.2 1
Nominal diameter 115 mm [4.53 in] 04 0.45 05 26 2.6 1
Serie “U” 05 0.56 05 32 3.2 1
Motor type
(USA) 07 0.75 05/1 38 3.8 1
Rotation CCW 09 0.9 05/1 43 4.3 1
Protection class IP 10 1.0 05/1 48 4.8 1
54
(with motor assembled on hydraulic power pack) 12 1.2 05/1 60 6.0 1
S2 / S3 duty service see curves 15 1.5 1
Insulation class F 17 1.7 1
Weight 6.7 kg [14.77 lb] 20 2.0 1

Performance with GR05 / GR1 pumps Performance with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]
US l/min US l/min
gpm 8.0 gpm 22

2.00 5.5
20
7.0
5.0
1.75 18
10 4.5
6.0
16
1.50
09 4.0

5.0 14
1.25 07 3.5

12
05 3.0
4.0
1.00
10
2.5 60
04
3.0 8
0.75 48
2.0
43
32
02 6 38
1.5 26
2.0
0.50 22
4 20
1.0
17
0.25 1.0 15
0.5 2 12

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022700/00-2012 38
25022700
®

Current with GR05 / GR1 pumps Current with GR05 / GR1 pumps
Displacement 0.2 ÷ 1.0 cc/rev [0.012 ÷ 0.061 in³/rev] Displacement 1.2 ÷ 6.0 cc/rev [0.073 ÷ 0.366 in³/rev]

Amp Amp
60 48 43 38
100 200
32
10
90 09 180

26
80 07 160

22
05
70 140 20
04
60 120
17
15
02
12
50 100

40 80

30 60

20 40

10 20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

S3
10 20
Motor with thermal switch
S2
8 16

6 12

4 8

2 4

0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 Amp

ORDERING CODE

Code Description Code Description


25022700 24VDC motor - 2.2 kW KIT07012.026 Starting switch kit 24VDC - 120A (fixing with screws)
25022900 24VDC motor - 2.2 kW with thermal swich

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 200A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022700/00-2012 39
25021300
®

24 VDC - 3.0 KW - D.125 MOTOR


27.6 [1.09] 138 [5.43]

22 [0.87]

M5 n°2

M8
Ø129 [5.08]
Ø125 [4.92]
Ø42 [1.65]

Ø50 [1.97]

102 [4.02]
Ø24.2 [0.95]
8 [0.31]

M6
6.5 [0.26] 12 [0.47] 12.5 [0.49]
Ø110.5 [4.35]
43 [1.69] 207.5 [8.17] mm [inches]
250.5 [9.86]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 3.0 kW 09 0.9 05/1 43 4.3 1
Nominal diameter 125 mm [4.92 in] 10 1.0 05/1 48 4.8 1
Wound field 12 1.2 05/1 60 6.0 1
Motor type
compound 15 1.5 1 63 6.3 1
Rotation CCW 17 1.7 1 78 7.8 1
Protection class IP 20 2.0 1
20
(with motor assembled on hydraulic power pack) 22 2.2 1
S2 / S3 duty service see curves 26 2.6 1
Insulation class F 32 3.2 1
Weight 12 kg [26.46 lb] 38 3.8 1

Performance with GR05 / GR1 pumps Performance with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 10 gpm 26

2.50 6.5
24
9
6.0
2.25 22
78
8 5.5
2.00 20
5.0 63
7 22
18 60
1.75 4.5
20
16
6
4.0
1.50 17
14 48
5 15 3.5
1.25 43
12 12
3.0 38
4
1.00 10 10
2.5 32
09 8
26
3 2.0
0.75

1.5 6
0.50 2

1.0 4

0.25 1
0.5 2

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25021300/00-2012 40
25021300
®

Current with GR05 / GR1 pumps Current with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32
240 300

22 280
220

20 260 26
200
240
180 17 220
15
160 200

12 180
140
160
120
10 140
100 09 120

80 100

80
60
60
40
40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24
Motor with thermal switch
10 20

8 16

6 12
S3
4 8
S2

2 4

0 0
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Amp

ORDERING CODE

Code Description Code Description


25021300 24VDC motor - 3.0 kW KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)
25023000 24VDC motor - 3.0 kW with thermal switch

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021300/00-2012 41
25021300 FAN
®

24 VDC - 3.0 KW - D.125 MOTOR

193,9 [7.63]
Ø 20 [0.79]

M5 n°2

8 [0.31]

M8
5 [0.2]

D1E1
Ø 125 [4.92]

Ø 129 [5.08]
Ø50 [1.97]

133 [5.24]
118 [4.65]
A2E2
M8

55.9 [2.2] 207,5 [8.17] Ø 110 [4.33]

X 263,4 [10.37] 118 [4.65]

133 [5.24] mm [inches]


X = see ordering code

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 3.0 kW 09 0.9 05/1 43 4.3 1
Nominal diameter 125 mm [4.92 in] 10 1.0 05/1 48 4.8 1
Wound field 12 1.2 05/1 60 6.0 1
Motor type
compound 15 1.5 1 63 6.3 1
Rotation CCW 17 1.7 1 78 7.8 1
Protection class IP 20 2.0 1
20
(with motor assembled on hydraulic power pack) 22 2.2 1
S2 / S3 duty service see curves 26 2.6 1
Insulation class F 32 3.2 1
Weight 13.1 kg [28.88 lb] 38 3.8 1

Performance with GR05 / GR1 pumps Performance with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 10 gpm 26

2.50 6.5
24
9
6.0
2.25 22
78
8 5.5
2.00 20
5.0 63
7 22
18 60
1.75 4.5
20
16
6
4.0
1.50 17
14 48
5 15 3.5
1.25 43
12 12
3.0 38
4
1.00 10 10
2.5 32
09 8
26
3 2.0
0.75

1.5 6
0.50 2

1.0 4

0.25 1
0.5 2

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25021300 FAN/00-2012 42
25021300 FAN
®

Current with GR05 / GR1 pumps Current with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32
240 300

22 280
220

20 260 26
200
240
180 17 220
15
160 200

12 180
140
160
120
10 140
100 09 120

80 100

80
60
60
40
40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
48 48

44 44

40 40

36 36

32 32
Motor with thermal switch
S3
28 28

24 24

20 20
S2
16 16

12 12

8 8

4 4

0 0
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Amp

ORDERING CODE

Code Code Description


Power Code Fan cooled Code
X KIT07012.019 Starting switch kit 24VDC - 150A (fixing with clamp)
Fan cooled motor Fan cooled
pack mm [inch]
motor with thermal kit
swich
FP 53.2 [2.09] KIT09008.029 * 25017700 * please contact our sales department
MC 43.4 [1.71] KIT01008.118 KIT01008.119 25006100

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25021300 FAN/00-2012 43
25022400
®

24 VDC - 3.0 KW - D.125 MOTOR


27,5 [1.08]

22 [0.87] 131,5 [5.18]

M8
M5 n°2
Ø 42 [1.65]
Ø 125 [4.92]

Ø 129 [5.08]
Ø 59 [2.32]

102 [4.02]
8 [0.31]
24,3 [0.96]

M6
6,5 [0.26] 12 [0.47] 11 [0.43]
110,5 [4.35]
43 [1.69] 200 [7.87]
mm [inches]
243 [9.57]

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 3.0 kW 09 0.9 05/1 43 4.3 1
Nominal diameter 125 mm [4.92 in] 10 1.0 05/1 48 4.8 1
Wound field 12 1.2 05/1 60 6.0 1
Motor type
compound 15 1.5 1 63 6.3 1
Rotation CCW 17 1.7 1 78 7.8 1
Protection class IP 20 2.0 1
20
(with motor assembled on hydraulic power pack) 22 2.2 1
S2 / S3 duty service see curves 26 2.6 1
Insulation class F 32 3.2 1
Weight 10,5 kg [23.15 lb] 38 3.8 1

Performance with GR05 / GR1 pumps Performance with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 10 gpm 26

2.50 6.5
24
9
6.0
2.25 22
78
8 5.5
2.00 20
5.0 63
7 22
18 60
1.75 4.5
20
16
6
4.0
1.50 17
14 48
5 15 3.5
1.25 43
12 12
3.0 38
4
1.00 10 10
2.5 32
09 8
26
3 2.0
0.75

1.5 6
0.50 2

1.0 4

0.25 1
0.5 2

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022400/00-2012 44
25022400
®

Current with GR05 / GR1 pumps Current with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32
240 300

22 280
220

20 260 26
200
240
180 17 220
15
160 200

12 180
140
160
120
10 140
100 09 120

80 100

80
60
60
40
40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
20 40

18 36

16 32

14 28

12 24

10 20

8 16

6 12
S3
4 8
S2

2 4

0 0
60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Amp

ORDERING CODE

Code Description Code Description


 25022400 24VDC motor - 3.0 kW KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022400/00-2012 45
25022400 FAN
®

24 VDC - 3.0 KW - D.125 MOTOR

187,4 [7.38]
Ø 20 [0.79]

M5 n°2

8 [0.31]

M8
5 [0.2]

D1E1
Ø 125 [4.92]

Ø 129 [5.08]
Ø 59 [2.32]

133 [5.24]
118 [4.65]
A2E2
M8

55.9 [2.2] 200 [7.87] Ø 110 [4.33]

X 255,9 [10.07] 118 [4.65]

133 [5.24] mm [inches]


X = see ordering code

RATED FEATURES PUMP TYPE

Voltage 24 VDC Code cc/rev. GR (Size) Code cc/rev. GR (Size)


Power 3.0 kW 09 0.9 05/1 43 4.3 1
Nominal diameter 125 mm [4.92 in] 10 1.0 05/1 48 4.8 1
Wound field 12 1.2 05/1 60 6.0 1
Motor type
compound 15 1.5 1 63 6.3 1
Rotation CCW 17 1.7 1 78 7.8 1
Protection class IP 20 2.0 1
20
(with motor assembled on hydraulic power pack) 22 2.2 1
S2 / S3 duty service see curves 26 2.6 1
Insulation class F 32 3.2 1
Weight 11.6 kg [25.57 lb] 38 3.8 1

Performance with GR05 / GR1 pumps Performance with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]
US l/min US l/min
gpm 10 gpm 26

2.50 6.5
24
9
6.0
2.25 22
78
8 5.5
2.00 20
5.0 63
7 22
18 60
1.75 4.5
20
16
6
4.0
1.50 17
14 48
5 15 3.5
1.25 43
12 12
3.0 38
4
1.00 10 10
2.5 32
09 8
26
3 2.0
0.75

1.5 6
0.50 2

1.0 4

0.25 1
0.5 2

0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

IE/25022400 FAN/00-2012 46
25022400 FAN
®

Current with GR05 / GR1 pumps Current with GR1 pumps


Displacement 0.9 ÷ 2.2 cc/rev [0.055 ÷ 0.134 in³/rev] Displacement 2.6 ÷ 7.8 cc/rev [0.159 ÷ 0.476 in³/rev]

Amp Amp
78 63 60 48 43 38 32
240 300

22 280
220

20 260 26
200
240
180 17 220
15
160 200

12 180
140
160
120
10 140
100 09 120

80 100

80
60
60
40
40
20
20

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 bar

0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi 0 300 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 psi

Thermal characteristics S2 - S3
S2 (min) S3 (%)
48 48

44 44

40 40

36 36

32 32
S3
28 28

24 24

20 20
S2
16 16

12 12

8 8

4 4

0 0
100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 Amp

ORDERING CODE

Code Code Description


Power Code Fan cooled Code
X KIT07012.019 Starting switch kit 24VDC - 150A (fixing with screws)
Fan cooled motor Fan cooled
pack mm [inch]
motor with thermal kit
swich
FP 53.2 [2.09] * * 25017700 * please contact our sales department
MC 43.4 [1.71] * * 25006100

Reference data: maximum nominal pressure Pmax = 290 bar. Oil ISO VG32 tempera- Maximum nominal current Imax = 300A. Stabilized voltage to 24 Vdc detected at the
ture 35°C (viscosity 40 cSt), outside temperature 25°C. terminals of the electric motor.

IE/25022400 FAN/00-2012 47
Starting switch: 120A
®

72 [2.83] RATED FEATURES


57.3 [2.26]
Female Faston Description 12 VDC 24 VDC
6.3-08 N.2 20 [0.79] 5 [0.2] 8.4 V @ 20°C 16.8 V @ 20°C
Min cut-on voltage
11 V @ 60°C 23 V @ 60°C

M6 N.2
Rated voltage 12 VDC 24 VDC
Cut off voltage 0.6 ÷ 4 VDC 1.2 ÷ 8 VDC
Ø 40 [1.57]

21 [0.83]
Current consumption 1.9 ± 0.2 A 0.8 ± 0.1 A
Operating temperature range -20 ÷ +60 °C -20 ÷ +60 °C
Vibration specification 9g 9g
Rated Current 120 A 120 A
mm [inches] Coil short time duty S2 = 15 min S2 = 20 min
Protection degree IP 67 IP 67
Weight 290 gr [0.69 lb] 320 gr [0.71 lb]

ORDERING CODE
Wiring diagram
Code Code
Motor type
(12 VDC) (24 VDC)
D. 80 fixing with clamp KIT07012.027 KIT07012.032
D. 115 fixing with clamp KIT07012.033 KIT07012.034
D. 115 fixing with screws KIT07012.025 KIT07012.026

Starting switch: 150A

182,5 [3.25]
RATED FEATURES
64,5 [2.54]

Female Faston 29 [1.15] 5 [0.2] Description 24 VDC


6.3-08 N.2 16.8 V @ 20°C
Min cut-on voltage
M8 N.2

23 V @ 60°C
Rated voltage 24 VDC
Cut off voltage 1.2 ÷ 8 VDC
Ø 54.5 [2.15]

26 [1.02]

Current consumption 1.1 ± 0.1 A


Operating temperature range -30 ÷ +60 °C
Vibration specification 9g
Rated Current 150 A
mm [inches] Coil short time duty S3= 10% @ 350A
Protection degree IP 54
Weight 690 gr [1.52 lb]

ORDERING CODE
Wiring diagram Code
Motor type
(24 VDC)
D. 125 fixing with screws KIT07012.019

IE/STARTING SWITCH/00-2012 48
® ®

DIRECT CURRENT MOTORS


Code DOC00053 - Rev. 06

Technical Catalogue
January
2018

web edition

Dana Brevini S.p.A.


Via Luciano Brevini 1/a
42124 Reggio Emilia
Tel. +39 0522 270711
Fax +39 0522 270660
www.dana.com/brevini
info@brevinifluidpower.com

You might also like