You are on page 1of 6
b 35D ss CARGO CARRYING APPLIANCE (CCA) CHECKLIST O dubai Petroleum (OUTBOUND | [7] INBOUND | [__] contractor Company: SfARRoos Matime Sevvices Ct [Actual wt (ka) CCAIDNo: Pc dot (Game as 1001 serial number of contsiner/basket..) =2Goo pestnaton: SWE - Fc {:..Fied - Rig Mstalaion or JAOSB) a ‘ALL ITEMS MUST BE COMPLETED PRIOR TO DISPATCH YN NA ‘a Doos the CCA (basketicontaineriank carry an inspection plate ? a 4b Does it show a least 4 month ull remaining before next Test Inspection is due ? wm 2. Isall loose lifting gear (Le. CCA's, shackles & slings) markedistamped with SWL and iD number? 3a Is tho ID Number, Gross Wt, Tare Wt and Net Wt clearly marked on the CCA? Tw: LSovqha PL:2150 kg @ 3b Is Actual (recorded) Wt less than or equal to Gross Wt ? Note: Never exceed Gross Wt ! GWG 4 Is there a destination label attached (or marked) on the CCA? ‘52 Are the doors and locking mechanisms proporly secured and with locking device attached ? ‘5b_Check the CCA is NOT rigged using ISO comer castings (not allowed for dynamic lifts offshore) (Ga Are the CCA's (baskets/containersitanks) free from excessive corrosion or holes ? {8b Confirm there are no loose plates (i.e. name plates etc) on the external surfaces of the CCA ‘Ave items packed to prevent movement! damage (Le. lashed or strapped) and internal sea fastenings adequate for “Worst Weather Conditions” ? ‘Are sumpldrainage areas free of liquids and are fuel/al fankelreservoirs secured to prevent leaks during shipment 2 ‘88 Have you checked for any loose objects, eg, tools, debris on the lift or In the fork pockets 7 9» Check integrity of forklift pockets (not loose}and that they are fully welded in place 410 Have all tubulars been slung correctly ? ‘ia Is the cargo restraining net secure and positioned to prevent goods from falling out ? Check that there are no ancillary items protruding outside of the cargo units crash frame that could get ‘hung up of knocked off n case of transit liquid carrying tanks (and drums), is there any evidence of leakage and are the tankidrum lids securely closed ? Have all stings been checked for damage / corrosion and are they properly equipped with a 4 plece safety shackle (Le. shackle, bolt, nut and securing split pin) ? 4 Have weights been checked against SWL of loose rigging equipment (ie, Siingslahackies) 7 ‘Remember SW o aging ep should be greater than ihe Gross Wt (Gross WI = Tave Wi + Net Wt) of CCA ‘Axe lifting points (pad eyes) and all loose (Cat 1) rigging equipment (such as slings & shackles) correctly colour coded ? 7 Soo a |g cocoado dood: © 9 Se0Ag Oo dood oy 010 OOQG| CO} Go 2 oogaq ag A O 8 6 arly ldentiied (Le, lifts > 2.8mt) ? 16 Ha heavy lifts been 17 Ensure all open units are supplied with drainage holes ? 18 Has all lifting gear certification been provided and checked (ie it in date) ? (ard party load test INDE/ Visual Inspection) If chemicals are being shipped Is the Chemical MSDS attached with the shipping documents ? nog ago a dodo dd oa@ oo Has Dangerous Goods cargo been notified and the container correctly labelled 7 ong 24_ DP Rep to confirm that load Is within platformitig crane capacity prior to loading on vessel = PORAMY MALLAH 0: WoxkStb? PLANYER, | Positio * | = _Date:s3 100712524! signature: ‘amo Tet Con Fem Arplus® VELOSI CERTIFICATE Of Test and Thorough Visual Examination of Li ing Equipment Certificate No.: _VADI/SPEO/0300181AD Date of Inspection: _ 19.04.2021 Name & Address of the Owner: : Place of Inspection: M/s. ADOS Sparrows offshore, Sapo Sparrows YARD,MUSSAFAH Maker or Supplier: ‘Standard/Procedure: SPARROWS BS 7072 & Client Requirements : M : Test Maximum ID No. ey. Description as Applied | Weight : CARGO BASKET ‘SPC 101 01 | ALL STEEL WELDED CONSTRUCTION C/W FOUR TOP LIFTING PAD EYES 6750 2700 DIMENSIONS: 2.2 m (L) x 1.3 m (W) x 1.15 m (Ht) ‘s ‘s PAD EYES DIM.: 110 mm (L) x 135 mm (H) x 22 mm (T) PAD EYE HOLE DIA.: 23 mm TARE WEIGHT 4050 ko ps pisgonal GROSS WEIGHT poesorel: NOTE: Shall be Lifted with four iting points and certified slings, Ifts test) ‘| shackles of sufficient SWL and dimensions, Pad eyes shall be modified in accordance with BS ISO 10855 on or before next inspection. i NDT REPORT NO.:VEL/ECT/2021/027 Insp. Dt.:19.04.202i ‘COLOUR CODE: White (FROM Jan 2021 TO Jun. 2021) COMMENTS: AT THE TIME OF INSPECTION THE ABOVE EQUIPMENT WAS FOUND SATISFACTOR} Date of Last Date of Next Date of Last Proof | Date of Next Proof Load Examination Examination Load Test Test 18.04.2025/ ON OR 18.12.2018 20.09.2018 18.10.2021 AFTER MAJOR REPAIR/ VADI/SPEO/260286aD QIS-ADS-050 iabaReATEe Date of fssuei 19.04.2021 [308 NO.; £29053-CRN-5102AD Timesheet No: 57129 ‘Authorized Name: K. VINOTH { Surveyors Name: Authorized Signature: ay EE” surveyor's signature: THIS IS TO CERTIFY THAT the above signed competent surveyor has thoroughly tested and visually examined the lifting equipment In the above-mentioned place as per U.A.E. Regulations Ministry Order No. (32) Year 1982- Article (20). The lablities and insurance i 28 per Velosi Certfication LLC. This Inspection Certifcate/Report shall not be reproduced except in full without the approvel of the Inspection Body and the Cent. LS-UAE-LEG-T Rev No. 00 Rev Date 01.06.2020, Page 1 of 1 Tee ZS Tov Rheintand® Spc tol Precisely Right. [Wer orer nar _soatetae4776 AveiNe IDNas AS SAT Aust Unie Nave Abu Dhabi TUVR Cenicate No. 60078 Coriicale No. SPARROWS.WRS-21.08.T0VR 2022 002 MF ‘The equipment cetaled below was examined in accordance wth UAE Law Decree 32 of 1082 Article 20, ADNOC Group Standord "HSE OBST ond standard BS EN 19414-1 2003"A2 7008 & BS EN TaBee 20CGeAT 200 Owner: | SPARROWS FZE. Se Sask 0 Bon 16604- Dube, UAE [Equipment Name: \WaRE ROPE SLING [Location of Inspection ‘Musatfah Type Of nepection: | Trorowgh Examination Witou Load Test [Date of nepecion Paaaeat Place of Inspection: | Musaftah [Date of Last Inspection ‘2104/2021 ie ‘Date of Last NDT: Not Applicable: [Date of Last Proof Load Test [21042021 z ‘Summary: if The folowing” WIRE ROPE SLING" have been and Visually Examined and found tobe suitable for further service with it recommendations as given hereunder oe a Equipment: Hi SH] AseiNe7O | Sera No Description SW Recommendations] £ : wr] ASSe7 AS 87 WIRE ROPE SLING Tater None. ES Ps 0-45 deg. i e Be g B ug h it ii Hi : ey de — Hf cams u Solor God: White Uni 30.06.2021 / Blue Unt Vay of Cece. fe E son Yeication; Tested. Tuo iin Equpment- Ret. no. 0964/21 - Date 21042021 Hi i Recommendation: ‘None ; ef | certify on behalf of the Third Party Company named above that the items described herein were Thoroughly Examined by myself being i i ‘2 Competent Person and were found at the time of inspection free from cracks, flaws, or other defects, unless otherwise stated above and considered to be Safe for Further Use, subject to continuous maintenance being applied and quatified operator/user being employed. = = es ‘Next insaction Due On: zoror02s Inspected By: ul ‘Next Proot Load Test Due On; NA ‘Mostata Fathy (20) : : i 4 Surveyor of TUV Rinond Mie Eas i oto i e SPARROWS-WRS-21-04-TUVR20-22- 00248 wet conine Eat wepyGusewcn

You might also like