You are on page 1of 4

useComissionamento SIU

conectar pelo TeraTerm


- login:admin
- senha:hidden

Inicia o Coresftp e deixa conectado.

Inicia o Putty

login:admin
senha:hidden

OSmon> startsession diogo


OperationSucceeded

OSmon> uselocalsftp on
OperationSucceeded
este é o caminho do arquivo
OSmon> download diogo sftp://siu:siu@192.168.1.2/180205_SLSPJN01_SIU-bup.xml
OperationSucceeded

OSmon> getsessionstatus diogo - este comando verifica se o download baixou


DownloadCompleted
OperationSucceeded

OSmon> restore diogo hidden - este comando irá reiniciar a SIU

OSmon> getcontainment STN=0 - este comando verifica se o site tem configuração.


STN=0;
STN=0,Equipment=0;
STN=0,EthernetInterface=SITE_LAN_0;
STN=0,EthernetInterface=SITE_LAN_1;
STN=0,IPInterface=INT_INFRA;
STN=0,IPInterface=INT_OM;
STN=0,IPInterface=INT_S1;
STN=0,IPv6RoutingTable=0;
STN=0,MeasurementDefinition=0;
STN=0,QosPolicy=QoS_Policy;
STN=0,RoutingTable=0;
STN=0,RoutingTable=0,IpRouteSys=DefaultGateway;
STN=0,RoutingTable=0,IpRouteSys=INT_INFRA;
STN=0,RoutingTable=0,IpRouteSys=INT_OM;
STN=0,RoutingTable=0,IpRouteSys=INT_S1;
STN=0,Synchronization=0;
STN=0,Synchronization=0,TimeServer=Time_Server_1;
STN=0,Synchronization=0,TimeServer=Time_Server_2;
STN=0,TrafficManager=TRAFFIC_MANAGER_0;
STN=0,TrafficManager=TRAFFIC_MANAGER_1;
STN=0,VLANGroup=VLANGROUP_SITE_LAN_0;
STN=0,VLANGroup=VLANGROUP_SITE_LAN_0,VLAN=VLAN_INFRA;
STN=0,VLANGroup=VLANGROUP_SITE_LAN_1;
STN=0,VLANGroup=VLANGROUP_SITE_LAN_1,VLAN=VLAN_OM;
STN=0,VLANGroup=VLANGROUP_SITE_LAN_1,VLAN=VLAN_S1;
OperationSucceeded

OperationSucceeded

OSmon> getmoattribute STN=0 - este comando tbm verifica se o site tem configuração só que
pelo nome do site em uma das linhas.
STN=0; instanceId= 0;
STN=0; operationalState= enabled;
STN=0; depIP_Interface= STN=0,IPInterface=INT_INFRA;
STN=0; depLocalRoutingPolicy= ;
STN=0; wakeUpRegistration= 0.0.0.0;
STN=0; wakeUpDestination= 10.192.6.140;
STN=0; wakeUpEventInterval= 1;
STN=0; SW_PrimaryProductNumber= CXP102138_1;
STN=0; SW_PrimaryProductRevision= R2Y16;
STN=0; SW_BackupProductNumber= CXP102138_1;
STN=0; SW_BackupProductRevision= R2Y16;
STN=0; alarmSupervisionActive= false;
STN=0; DSCP_OperationAndMaintenance= 16;
STN=0; DSCP_OM_FileTransfer= 16;
STN=0; STN_PGW_KeepalivePeriod= 1;
STN=0; STN_PGW_L2TP_MaxTransmissions= 5;
STN=0; STN_PGW_L2TP_RetransmissionCap= 4;
STN=0; STN_PGW_L2TP_InitialRetransmissionPeriod= 1;
STN=0; STN_Name= SLSPJN01_SIU;
STN=0; restartReason= CM_Config;
STN=0; systemClockTimeServer= 10.36.154.38;
STN=0; systemClockTimeServerType= NTP;
STN=0; STN_systemClockUDP_Port= 123;
STN=0; systemClockUDP_Port_General_PTP= 320;
STN=0; systemClockUDP_Port_Event_PTP= 319;
STN=0; contactWithFileServer= true;
STN=0; systemClockPTPDomainNumber= -1;
STN=0; userLabel= ;
STN=0; lastConfigChange= ;
STN=0; promptPrefix= ;
STN=0; arpPcp= 6;
OperationSucceeded

OSmon> getalarmlist - este comando vai listar os alarmes presentes no site.


STN=0,Equipment=0;
alarmId= 1;
eventTime= 1970-01-01 T00:00:46;
eventType= "equipmentAlarm(4)";
perceivedSeverity= "minor(3)";
probableCause= "x733EquipmentMalfunction(315)";
specificProblem= "Hardware Fault";
additionalText= "Fan fault";

OperationSucceeded

OSmon> getmoattribute STN=0,EthernetInterface=SITE_LAN_1 - Este comando verifica a


porta da SIU
STN=0,EthernetInterface=SITE_LAN_1; instanceId= SITE_LAN_1;
STN=0,EthernetInterface=SITE_LAN_1; operationalState= enabled;
STN=0,EthernetInterface=SITE_LAN_1; MAC_Address= 74:C9:9A:C0:52:A6;
STN=0,EthernetInterface=SITE_LAN_1; port= SFP;
STN=0,EthernetInterface=SITE_LAN_1; mode= AUTO;
STN=0,EthernetInterface=SITE_LAN_1; currentMode= gigabit;
STN=0,EthernetInterface=SITE_LAN_1; portNumber= 1;
STN=0,EthernetInterface=SITE_LAN_1; ethMaxFrameSize= 1522;
STN=0,EthernetInterface=SITE_LAN_1; flowControl= off;
STN=0,EthernetInterface=SITE_LAN_1; sendLinkAlarmAllowed= true;
STN=0,EthernetInterface=SITE_LAN_1; depTrafficManager=
STN=0,TrafficManager=TRAFFIC_MANAGER_1;
STN=0,EthernetInterface=SITE_LAN_1; ptpInterfaceGroup= none;
OperationSucceeded

OSmon> getalarmlist - verifica os alarmes na SIU


STN=0,EthernetInterface=SITE_LAN_0;
alarmId= 1;
eventTime= 1970-01-01 T00:00:58;
eventType= "communicationsAlarm(2)";
perceivedSeverity= "major(2)";
probableCause= "x733LossOfSignal(329)";
specificProblem= "Ethernet Interface Down";
additionalText= "Ethernet Interface Link Down - physical port 0";

OperationSucceeded

OSmon>startTransaction teste

OSmon>setmoattribute teste STN=0,Ethernet=SITE_LAN_1 modegigabitfullduplex - esse


comando altera modo que a porta trabalha

OSmon> resettofactorysetting - zera a configuração da SIU

Warning: All user settings will be removed, continue


(ok/cancel)? ok

OperationSucceeded

You might also like