Floodlights BATS53 Series Explosion-proof Floodlights © Explosion protection to -CENELEC sec “NEC © Can be used in Zone 1 and Zone 2 Zone 21 and Zone 2 Class |, Zane + and Zane 2 (lass | Dvsion 2, Groups C, D Class | Dvsion 1, Groups C, D “Four enclosure types: 125, 250,400, 1000. © Integral contol gear, easy instalation and maintenance. ‘© Rapid starting tiger, stable perfomance and long servic ie {© Enclosure in Copperree Aluminium Alloy, power coated surface, yelow (RALTO21). © Toughened las cover resistant o temperature changes. 1 Catalogue number logic Bars3- 0-000 5: sree amp type (ony fo BATS.250 ype, Se P2110) Mowing | ¥en Npe 6 tied Woe Lame power) HE: Metal hale lamp itn |___ sr atr g oe Enclosure type: 125, 250,400, 1000, Explosion-prooffoodighis | Selection table ‘Available lamp power (W) ‘Type/Orderng code = as we Lamp holder | Weight ko) BBATSS-125 70,100, 150 70,100 20, 125 a 345 BATS9-260 250 160, 250 260 E40 1475 BATSS-400 400 400 : E40 30.75 ‘BATSS-1000 1000 1000 : E40 115.00 Note 1. Pease specity any spare pars when ordering. See Accossories table. 2.125, 260 and 400 ype light ftngs ae supplied without lamp. PHILIPS lamps are recommended 3. HPI European standard ballasts supplied with HIE ight ting. HPI European slandard lamps are recommended, 41000 type ight tings are supplies wit lamp and bali. Zones 1&2; 21&22 ania General Catalogue 01.01.2020 ts wen waromroup.com Floodlights BATS3 Series Explosion-proof Floodlights Explosion-proof floodlights. —— BATS3-125-1010) Explosion protection Global (ECEX) IE Cex COM 13,0037 Gas and cst Exde lB Tb x th INC TL" Db Pos Europe (ATEX) ET 18 ATEX 2030X (Gas and dust 12.6 Ex cb 0B 7) Gb @®I120 Ext TH" De Ps S09 Selection table Certificates IECEx: ATEX; CUTR Conformity to standards EN 600780, EN 60079-1, EN 60079-7, EN 60079.31 IEC 60079-0, IEC 60079-1, IEC 600797, IEC E0078-31 Material Enclosure CCopper-ree Aluminium Aloy, powder coated surface, yllow (RAL1021) Gis cover ‘Toughened glass, stands 44 impact Ballast Electromagnetic ballast, rapid staring, stable performance Wire guars Powder coated carbon steel, white Internal reflector High-punity aluminian Explosion proof electronic tigger (cost = 0.90 (compensated) Stainless ste! ‘Lamp holder er ‘Available lamp and lamp power (W) High pressure sodium lam (HSE): TOW, 10017 High pressure mercury amp (HME): BOW, 12507 Meta halide lamp (HIE): 70W, 100, 150¥/ Note: HI European standard baat avallabio in general 220-240 AC SOHz (60Hzis optional) Earthing protection IMS (intemal & external earth bots) Degree of protection Pes ‘Ambient temperature 800~*550 Terminal 3x 1.5-2.5mn¥ (LeNSPE) Cable entries 2x 021: 1xM20 x15 cable gland [OGM Ex 6) 1 x20. 15 plug Available cable outer diameter (05-010 (mm) ‘Temperature classes tm a eo) ost we THe THs mse 70 THse se mse 100 Ties res we Ther Tere WE 380 THe Teo wwe a) these These wwe 28 tao Ta08 ane 6aep0 01012020 Mi wwmnrmae con ans WARM Floodlights BATS53 Series Explosion-proof Floodlights Explosion-proof floodlights Explosion protection Gobel (IECEX) Gas and aust Europe (ATEX) Gas and cust contiicates Conformity to standards Material Enclosure Glass cover Ballast Wire guars Internal tector Tigger Power factor Exposed fastener Lamp Lamp holder ‘Avaable lamp and lamp power (W) Rated voltage Earthing protection Degree of protection ‘Ambient temperature Terminal Cable entries ‘Avallable cable outer dlameter BATS3-250-0010 ECE CM 07 0004 Exdell8 73 Gb LIE 05 ATEX 6143, ®u2cexaousrs IECEx; ATEX; CU-TR EN 60079-0, EN 60070-1, EN 60079-7 EC 60079-0, IEC 6007941, IEC 60O7S-7 CCopper-res Aluminium Alloy, powder costed surface, yellow (RAL 1021) “Toughened glass, stands 4 impact Electromagnetic ballast. rapid staring, stable performance Powder coated carbon ste! white High-purityaluminiom Explosion proof election tigger COS@ =0.90 (compensated) Stainlee ste! 40 High pressure socium lamp (HSE): 160W, 250 High pressure mercury lamp (HME} 25010 Metal halide lamp (HIE): 25000 Note: HPI European standard baat is vallabe in general £220-240V AC S0Hz (60Hzis optional) MS (ternal & external earth bots) 16s 20-455 8 1.5-2.5mm (LENSPE) 2 26:1 x425 x15 cable gland (DQM-IEx e}.1 M25 x 1.5 plug 910-014 (mm) 26 General Catalogue 01.01.2020 ts wen waromroup.com Floodlights BATS3 Series Explosion-proof Floodlights Explosion-proof floodlights BATS3-400-110] Explosion protection Global (ECEX) IECEx COM 08.0014 Gas and du ExdeusTs Europe (ATEX) LIE O7 ATEX 6108 Gas anc dust @i2cexseusrs Cortiicates ECE, ATEX Conformity to standards EN 60079-0, EN 60078-1, EN 60079.7 EC 60079-0, IEC 60071, 1EC 60079-7 Material Enclosure CCopper-ree Aluminium Alloy, powder coated surface, yetow (RAL1021) ceed “Toughened glass, stands 4J impact Ballast Electromagnetic balast, rapid starting, stable perormance Internal refector High purty aluminium Tigger Explosion roof laconic tigger Power factor (COS =0.90 (compensated) Exposed fastener Stainless stot Wire guard (optional) Powder coated carbon steel, white Lamp ‘Lamp holder E40 ‘Available lamp and lamp power (W) High pressure sodium lamp (HSE): 400W (tubular) Meta hale tap (HIE): 400W (tubular) Note: HI European standard balast is availabe in general Rated voltage 220-240 AC SOHz (602i optional) Eanthing protection IMS (intemal & external earth bots) Degree of protection P66 Ambient tomperature 200-1550 Terminal 23 1.54 (LNSPE) Cable entries 22x M25 15: 1 xM25.x 1.5 cable gland (QM Exe).1 xM25.x 1.5 plug ‘Avaliable cable outer diameter 010-014 (rm) soneos General Catalogue 01.01 2020. ti! wwn.waramgroup.com ani WARM Floodlights BATS53 Series Explosion-proof Floodlights Explosion-proof floodlights Explosion protection (Global (IECEx) Gas and cust Europe (ATEX) Gas and cust certificates Conformity to standards Material Enclosure Glass cover Ballast Tigger Power factor Internal efector Exposed fastener Lamp Lamp holder ‘Avaable lamp and lamp power (W) Rated voltage Earthing protection Degree of protection “Ambient temperature Terminal Cable entries Cable gland Available cable outer diameter ani BATS3-1000-010) ECE COM 14.0066x xd 1B T3 Co Extb IC TIG3°C Db IPE EPT 15 ATEX 1977 @u2cexaitse ®i20 Ext lc T193 Db Pes IECEx, ATEX: CUTR EN 60079-0, EN 60079-1, EN 60078:31 NEC 60079.9, IEC 60079-1, IEC 60079-31 ‘Welded carbon stel, powder coated surtace, yellow (RAL1021) Toughened glass, stands 4y impact Elecromagnatic ballast, rap staring, stable performance General tigger COS@ =0.90 (compensated) igh-puntyaluminiom Stainless steel E40 High pressure socum lamp (HSE):1000W Metal halide lamp (HIE) 10000 Noto: HP! European standard baat vallabe in general 230V AC S0Hz (60H2 is optional) 1s (itera! & external earth bots) \es 20-458 3 1.5-Amm(LeNSPE) 1x28 x 15 “The cable between floodight and ballast through BNG-M2S x 1.5(M)M25 x 151M) ‘explosion roof flexible conduit engi: 1000 mm); One explosion proof cable land (OOMIL825 x 1.5, Ex, bras, amorad, cable wiring) 010-014 (mm) General Catalogue 01.01.2020 ts wen waromroup.com Floodlights BATS3 Series Explosion-proof Floodlights BATS3-125-100] BATS3-250-0 101] BATS3-400-<1010] ted urns fx ‘Rated urinous fa ated aris x TOW Met hae lam: 5500 im 250W Moa aldo lamp: 23200 Im 400W Meta ald lap: 42500 Im ‘000 Metal Fake lamp: 8700 in {SOW High pressure eodum lam: 18000 Im 400W High pressure sour ame: S00 Im +1900” Metal rae lamp: 13500 im 250 High pressure sock lap: 33200 in The data tom Phips amp TOW High pressure soi amp: 8500250 High presse merry lap: 13000 ky {0007 High pressure sodium lamp: 10700 The data kom Pips lame BOW High pressure mercury lamp: 3200 "2501 High esse mercy er 6300 In “The data om Phlps bmp We can provide lighting design and data by professional ighting software DIALUX based upon simulated ste situation on request. Picture ie Cerin ode Weight) : Stns elton vase &S (ans cea op 125 Explosion-proof capacitor 83012 045 250 Expl car sos 0a Se 480 Explosion poo capcice sot oss 125 Morb sport e018 90 a 7 250 Movable support soe 288 Note: Blast see P1/21 General Catalogue 01.01 2020. ti! wwn.waramgroup.com 219 Street Lamps Explosion-proof Street Lamps a ea ; rf en an. oT “ta, leprae LeDigten | i i j se 5 a 5 h hOOT erze.ers0) aus ous, BOD! series _BATSS.250 series BATS2-400 series BnTS1-400 series BAMS2 series BATES eaves HRTSt series oz sed for patio srs mp the hap oto pos: 6m o Gm * > 0 Stongtnon sto fare = Meunting base our bse sea: Bantam ype reat mp, 2 Pita yp st the eight of the pe: “Om 62m, General Catalogue 01.01 2020. ti! wwn.waramgroup.com 21129

You might also like