1. Write the advantages of shell type transformer over core type transformer.
2. What are the salient features of distribution transformer?
3. Write the output equation of 1 and 3 phase transformer.
4. Define Window space factor.
5. Why circular coils are preferred in transformers?
6. List the types of Transformer windings.
7. What are the types of cooling of transformers?
8.Write the factors limit the armature diameter of DC machine

PART-B (13+13+8=34 Marks)

9. Estimate the core and window areas of single phase core type transformer at 1000KVA, 6600/440 V,
50Hz, flux density of 1.25 wb/m2 and current density of 2.5 A/mm2 ,Voltage per turn =30v . window space
factor=0.32 (13)

10.A 250KVA, 6600/400 V, 3 phase core type transformer has a total loss of 4800W. The transformer
tank is 1.25 m in height and 1m x 0.5 m in plan. Design the transformer tank is 1.25 m in height and
1m x 0.5 m in plan. with suitable tubes with the avg temperature is 35 0C. The diameter of the tube 50mm
and are spaced between 75mm . loss due to the radiation and convection are 6 and 6.5 w/m 2 c (13)

11.For a 250KVA, 1100V, 12pole 500rpm, 3 phase alternator. Determine core diameter and core length.
Assuming average gap density as 0.6 wb/m2 and specific electric loading of 30000 amp.cond/m, L/ι=1.5. (8).