Laminar Flow
Wall Paneling
Vinyl Flooring
During a surgical operation, an operating room is required to be well equipped for the
necessary actions to be taken; “To go the extra mile to keep the operating room sterile” in
order to provide the care needed for the patients with specific conditions. Operating rooms
are aseptic areas.
this spesific application requires Anti- sheet flooring with 'TRUESHIELD' DOP content EN 15777 n/a Pass
Heavy metal EN71-3
Bacterial coating which is certified by coating and 'T' group wear Impact sound reduction ISO 10140 dB 3
AMS laboratories in still water NSW resistance, an ideal product for sterile ISO 717-2
PERFORMANCE BEHAVIOR
Australia. Our simple slip joint system and septic areas. Sheet width EN 426 m 2
for easy and fast construction, and fire Best antimicrobial & antifungal Sheet length EN 426 m 13-20
and Biohazard Waste Disposal depot. vibrant shades. Color fastness ISO 105-B02 rating ≥6
Resistance to staining EN 423 n/a No Stain 0
For Medicine Storage Room complies Castor Chair Underfloor heating Antimicrobial and antifungal
with PerKeMenkes RS tahun 2016 for Antistatic behavior Chemical resistance
1 2
Isolated Power System Laminar Flow Unit
Isolated power provides two types of safety: A Typical System for an Operating Theatre will include
1. Continuity of supply i.e. the isolated supply removes the Floor standing Enclosure Containing: Vertical clean air Laminar Flow is the most effective way to Control Microbe Levels in The Entire
possibility of 8 Kva Medical Grade Isolation Transformer
earth faults therefore there is no need to blow a fuse or trip a Medical Grade Line Insulation Monitor
Operation Theatre. Compared to conventional turbulent ventilation, vertical laminar air flow can
breaker to X 16 Double Pole mcbs decrease the number of post-operative infections substantially. The advantages of an air exchange
protect against earth leakage currents that could cause Earth Fault Detection System to ( IEC615557-8/9) system for the entire operating theatre have been established conclusively in a number of studies. In
electrical 1 Remote Alarm Unit laminar airflow system, the entire air mass circulates in one direction and displaces the existing air in
shock. UPS by- pass Switch the operating area. The first crucial step in vertical laminar flow takes place when incoming air is
2. Isolation from earth allows only negligible electrical current to 10 Kva UPS with a 10 minutes autonomy
flow blown straight down through HEPA filters above the operating table (the downward airflow prevents
though body –even an RCD will allow up to a 30mA-not air masses from mixing in the work area).
sensitive
enough for a medical environment. About 10 % to 30 % of the total air is vented out of room and being replaced by fresh air according
Features to the good design of the AHU ( Air Handling Units ) System. Rest of the air in the room is re
• Multi-bladed units, specifically designed control O.T room air pressures.
• Unit comprises of carbon steel housing with grade 304 stainless steel blades
circulated, filtered and blown back into the room. In this way, increased amount of fresh air is not
• Balancing is carried out utilizing a proven balance weight assembly needed, which keeps energy costs down when compared to conventional Air conditioning systems.
• Accurate to range of 1 pascal over their working range of 5-35 Pa.
• Adjustment can easily be carried out on site, should the need arise.
PRD ‘s are Pressure Stabilizer fixed inside the OT to maintain a positive pressure inside the
Operation Theatre
Features
• Multi-bladed units, specifically designed control O.T room air pressures.
• Unit comprises of carbon steel housing with grade 304
stainless steel blades
• Balancing is carried out utilizing a proven balance weight assembly
• Accurate to range of 1 pascal over their working range of 5-35 Pa.
3 4
Surgeons Control Panels ARK Modular Operating Theatre Low
6m
• Time elapse clock
• Standard clock
• Control for temp/ Humi 36 m2
• Touch screen
• Control for peripheral/O.T light
• IPS alarm
• Medical gas alarm & IPS alarm – Visual &
Audio
6m
ARK-MOT-M
8m
48 m2
6m
5 6