Professional Documents
Culture Documents
Issue 01
Date 2018-08-20
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Contents
1 Overview......................................................................................................................................... 1
1.1 Exterior ......................................................................................................................................................................... 1
1.2 Ports .............................................................................................................................................................................. 2
1 Overview
The AAU5313 is an RF module that integrates array antennas and RF units. The AAU5313
provides 32 RF channels and supports massive MIMO.
1.1 Exterior
1.2 Ports
1.1 Exterior
Figure 1-1 shows the AAU5313 exterior.
1.2 Ports
Figure 1-2 describes the physical ports on an AAU.
2 Technical Specifications
2.4 Capacity
Table 2-3 AAU5313 NR capacity
Frequency Band NR Capacity
Item Specifications
Item Specifications
Maximum distance from the BBU When 25 Gbit/s optical modules are used, the
maximum length of fiber optic cables between
the BBU and AAU must be less than 10 km.
When 10 Gbit/s optical modules are used, the
maximum length of fiber optic cables between
the BBU and AAU must be less than 20 km.
When the ambient temperature of the NR static sensitivity is 25°C, the test configuration should comply
with 3GPP TS 38.104 (QPSK, R=1/3, 51 RBs).
The typical power consumption refers to the power consumption when the module runs with 50% load
at the 25°C ambient temperature. The actual typical power consumption has a 10% deviation from this
value.
Item Specifications
Item Specifications
Side: 200 N (Assume that the wind speed is 150 km/h.)
Rear: 460 N (Assume that the wind speed is 150 km/h.)
Relative 5% RH to 100% RH
humidity
Atmospheric 70 kPa to 106 kPa
pressure
Operating The operating environment of the AAU5282 must comply with the
environment following standards:
3GPP TS38.141
ETSI300019-1-4 V2.2.1(2014-04) Class 4.1: "Non-weatherprotected
locations"
Anti-seismic YD5083-1999: Interim Provisions for Test of Anti-seismic
protection Performances of Telecommunications Equipment (telecom industry
standard in People's Republic of China)
ETSI300019-2-3(V2.4.1 2015-12)
GR63-CORE, Issue 4, April 2012 Zone4
Ingress IP65
protection
(IP) rating
Surge IEC 62305-1 Protection against lightning - Part 1: General principles
protection IEC 62305-3 Protection against lightning - Part 3: Physical damage to
structures and life hazard
IEC 62305-4 Protection against lightning - Part 4: Electrical and
electronic systems within structures
ITU-T K.35 Bonding configurations and earthing at remote electronic
sites
ITU-T K.56 Protection of radio base stations against lightning
discharges
ITU-T K.97 Lightning protection of distributed base stations
ETSI EN 300 253 Environmental Engineering(EE): Earthing and
bonding configuration inside telecommunications centers
YD 2324-2011: Lightning protection requirements and test methods for
radio base stations
GB/T 50689-2011: Code for design of lightning protection and
earthing engineering for telecommunication bureaus (stations)