Professional Documents
Culture Documents
Emc Test Report: Tim Chen Andy Zhang
Emc Test Report: Tim Chen Andy Zhang
: HX1811045844
Page : 1 of 25
Tim Chen
Test/Witness Engineer :
This report details the results of the testing carried out on one sample. The results contained in
this test report do not relate to other samples of the same product. The manufacturer should
ensure that all products in series production are in conformity with the product sample detailed
in the report.
TABLE OF CONTENTS
1. General Information
1.1. Client Information
Applicant : Liking Energy Technology Co., Ltd.
#801 GUANGYUAN BUILDING ,NO.255, RENMING SOUTH
Address :
ROAD,HUMEN TOWN,DONGGUAN,CHINA
Manufacturer : Liking Energy Technology Co., Ltd.
#801 GUANGYUAN BUILDING ,NO.255, RENMING SOUTH
Address :
ROAD,HUMEN TOWN,DONGGUAN,CHINA
Criterion B: After the test, the equipment shall continue to operate as intended without
operator intervention. No degradation of performance or loss of function is allowed, after
Report No.: HX1811045844
Page : 4 of 25
HX-EMC001 EMI Test Receiver Rohde & Schwarz ESCS30 Jan.02, 2018 1 Year
HX-EMC001 EMI Test Receiver Rohde & Schwarz ESCS30 Jan.02, 2018 1 Year
Triple-Loop
HX-EMC027 EVERFINE LLA-2 Jan.02, 2018 1 Year
Antenna
HX-EMC004 EMI Test Receiver Rohde & Schwarz ESI26 Jan.02, 2018 1 Year
EM Injection
HX-EMC013 LUTHI EM101 Jan.02, 2018 1 Year
Clamp
3.7. Test Equipment Used to Measure Radio Frequency Electromagnetic Fields
Immunity
No. Equipment Manufacturer Model No. Last Cal. Cal. Interval
HX-EMC014 Signal Generator Rohde & Schwarz SMT03 Jan.02, 2018 1 Year
Power Meter Rohde & Schwarz NRVD Jan.02, 2018 1 Year
HX-EMC015
Voltage Probe Rohde & Schwarz URV5-Z2 Jan.02, 2018 1 Year
HX-EMC016
Voltage Probe Rohde & Schwarz URV5-Z2 Jan.02, 2018 1 Year
HX-EMC017
Power Amplifier AR 150W1000 Jan.02, 2018 1 Year
HX-EMC018
Bilog Antenna Chase CBL6111C Jan.02, 2018 1 Year
HX-EMC019
3.10. Test Equipment Used to Measure Voltage Dips and Interruptions Immunity
Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
back and forth in the center forming a bundle 30 to 40 cm long.
I/O cables that are not connected to a peripheral shall be bundled in the center. The
end of the cable may be terminated, if required, using the correct terminating
impedance. The overall length shall not exceed 1 m.
The bandwidth of EMI test receiver is set at 9kHz, and the test frequency band is from
9KHz to 30MHz.
The frequency range from 9KHz to 30MHz is investigated. The receiver is measured
with the quasi-peak detector. For frequency band 9KHz to 150KHz, the bandwidth of
the field strength meter is set at 200Hz. For frequency band 150KHz to 30MHz, the
bandwidth is set at 9KHz.
Report No.: HX1811045844
Page : 11 of 25
Operating Mode: ON
Test Specification: X Direction
Report No.: HX1811045844
Page : 13 of 25
Operating Mode: ON
Test Specification: Y Direction
Report No.: HX1811045844
Page : 14 of 25
Operating Mode: ON
Test Specification: Z Direction
Report No.: HX1811045844
Page : 15 of 25
The height of the equipment or of the substitution antenna shall be 0.8 m; the height of
the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical
polarizations of the antenna are set to make the measurement.
The initial step in collecting radiated emission data is a spectrum analyzer peak
detector mode pre-scanning the measurement frequency range. Significant peaks are
then marked and then Quasi Peak detector mode re-measured.
Report No.: HX1811045844
Page : 16 of 25
If the Peak Mode measured value compliance with and lower than Quasi Peak Mode
Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode
measurement performed.
Operating Mode: ON
Test Specification: Horizontal
Report No.: HX1811045844
Page : 18 of 25
Operating Mode: ON
Test Specification: Vertical
Report No.: HX1811045844
Page : 19 of 25
1 ±2 ±2
2 ±4 ±4
3 ±6 ±8
4 ±8 ±15
X Special Special
each pre-selected test point. This procedure shall be repeated until all the air
discharge completed.
7.3.2. Contact Discharge:
All the procedure shall be same as air discharge. Except that the tip of the
discharge electrode shall touch the EUT before the discharge switch is operated.
7.3.3. Indirect discharge for horizontal coupling plane
At least 10 single discharges (in the most sensitive polarity) shall be applied at the
front edge of each HCP opposite the center point of each unit (if applicable) of the
EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode
shall be in the plane of the HCP and perpendicular to its front edge during the
discharge.
7.3.4. Indirect discharge for vertical coupling plane
At least 10 single discharges (in the most sensitive polarity) shall be applied to the
center of one vertical edge of the coupling plane. The coupling plane, of dimensions
0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT.
Discharges shall be applied to the coupling plane, with this plane in sufficient different
positions that the four faces of the EUT are completely illuminated.
Criterion: B
Button A PASS
Screw C PASS
HCP C PASS
Remark:
Report No.: HX1811045844
Page : 22 of 25
1 1
2 3
3 10
X Special
In order to judge the EUT performance, a camera is used to monitor its screen.
Criterion: A
Modulation: Unmodulated
80~1000MHz /
END OF REPORT