Model (KSY) (KW) - 3Phase GTI 15 18 20 25 25 33 35 40 50 60 70 75 80 100 100
Input (DC)
Ma x Pea k DC Input Power (KW) 16.5 20 22 27.5 27.5 36 38.5 44 55 66 77 82.5 88 110 120
Ma x. DC I/P (V dc) 1000 VDC 1000 VDC
Ma x. MPPT I/P Current(A) 10/20A 20A 28.5A 28.5A 34A
MPPT Short Ci rcui t Current(A) 15/26A 26A 36A 37 Amps
MPPT Tra cki ng Vol ta ge(Vdc) 200-850V 200-1000V
Mi n. Sta rt Vol ta ge(V) 250 VDC
Number of MPPT Tra cker 2 2 3 3/4 4
s tri ngs per MPPT Tra ckers 2 2 3 3 3/4 3 3/4 4 6
Output (AC)
Ra ted output power (KW) 15 18 20 25 25 33 35 40 50 60 70 75 80 100 110
Ra ted Gri d Vol ta ge(V) 400 VAC
Nomi na l Gri d freq.(Hz) 50Hz
Ma x. output current AC(A ) 26.1 29 29 36.2 36.2 47.8 50.7 58 72.4 87 101.4 108.7 115.9 144.5 159.4
AC Connec on (Wi th PE) 3P + N + E
THDI (%) 2.5-5% <3%
Output Power fa ctor(%) >0.99%
Efficiency
Ma x. convers i on eff. (%) 97%
Ma x. Euro Effi ci ency(%) 98.5 98.2
Ma x. MPPT Efi ci ency (%) >99%
Physical Parameters
380x435
Di mens i ons (LXHXW) mm 400x520x240 485x630x270 520x700x270 577x838 x323
x190
Wei ght (Kg) 18 31 38 68 80 83
Encl os ure Col or PANTONE Cool Grey 3 C
Col or Thi cknes s 100-250µ(mi cron)
General Data
Opera ng Tempera ture - 25 ° to + 60°
Opera ng Surroundi ng Humi di ty 0-100%
Des i gn Li fe Over 25 yea rs
Ni ght Con. (W)/Noi s e Level <1W/<30dB
Hea t Di s s i pa on i ntel i gent Forced Cool i ng + Na tura l Convec on

RH/Ma x. Al tude 0% to 98%. No Condens a on/<2000 wi thout power dera ng


Di s pl a y Gra phi ca l -LED wi th LCD Di s pl a y
DC /AC Connectors (IP-65) MC-4
Communi ca on i nterfa ce Wi Fi /GPRS/RS 485/RS 232/ETHERNET LAN/ Loca l Moni tori ng

Sta nda rd Wa rra nty 7 Yea rs (extenda bl e upto 10 Yea r)


Standards, Safety & Protec ons
DC Swi tch Inbui l t
SPD (s urge Protec on Devi ce) Type-3 SPD (Wi th GDT op ona l ) Type-2 / Type-3 SPD / GDT
MPPT Effi ci ency IEC 61683
Inverter Effi ci ency IEC 61683
Over Vol ta ge Ca tegory IEC 62109-1
Sa fety Sta nda rd IEC 62109-1&2
EMC Sta nda rd IEC61000-6-1/2/3/4
Emnvi ronment Protec on IEC 60068-2-1/2/14/15
An -Is l a ndi ng IEC-62116
Ingres s Protec on IP 65

PV Li gh ni ng,DC i nput s hort ci rcui t,DC O/V & U/V,Ins ul a on Res i s ta nce detec on,RCCB/ELCB, Output
Over /Under vol ta ge,Outpur Over current, Output Over/Under frequency, Over temera ture, GDT
Protec on & Sa fety
(op ona l ) , SPD a s per requi rement Type-2&3, AC output PF control ,AC output power control by us i ng