Professional Documents
Culture Documents
Table of Contents
7.1 Connectors [P (Plug) / J (Jack)] ................................................................................7-2
7.1.1 P/J List.................................................................................................................................... 7-2
7.2 P/J Layout .................................................................................................................7-5
7.3 Connection Chart ....................................................................................................7-12
7.3.1 Symbols in Overall Connection Chart................................................................................... 7-12
7.3.2 Overall Connection Chart ..................................................................................................... 7-13
7.4 Connection Charts Between Parts..........................................................................7-14
7.4.1 Notes on using the Connection Charts Between Parts ........................................................ 7-14
7.4.2 Organization of the Connection Charts Between Parts ........................................................ 7-16
1 DC POWER SUPPLY ................................................................................................................... 7-18
2 MSI & REGI .................................................................................................................................. 7-20
3 FEEDER (500) .............................................................................................................................. 7-22
4 ROS .............................................................................................................................................. 7-24
5 XEROGRAPHIC ........................................................................................................................... 7-26
6 HIGH VOLTAGE ........................................................................................................................... 7-28
7 DEVELOPER ................................................................................................................................ 7-30
8 2nd BTR ........................................................................................................................................ 7-32
9 FUSER .......................................................................................................................................... 7-34
10 CONTROLLER ........................................................................................................................... 7-36
11 DUPLEX ...................................................................................................................................... 7-38
7-1
Chapter 7 Wiring Data
7.1 Connectors [P (Plug) / J (Jack)]
7-2
Chapter 7 Wiring Data
7.1 Connectors [P (Plug) / J (Jack)]
7-3
Chapter 7 Wiring Data
7.1 Connectors [P (Plug) / J (Jack)]
DUP
P/J Coordinates Remarks
Connection between the SWITCH-DUP DOOR and the HARNESS-ASSY
122 G-207
DUP1
Connection between the SENSOR LOW PASS and the HARNESS-ASSY
123 E-209
DUP2
Connection between the SENSOR UPPER PASS and the HARNESS-ASSY
124 F-205
DUP1
Connection between the SENSOR UPPER PASS and the MOTOR ASSY
442 H-209
DUP
443 G-209 Connection between the PWBA DUP-L and the HARNESS-ASSY DUP2
444 H-208 Connection between the PWBA DUP-L and the HARNESS-ASSY DUP1
Connection between the HARNESS ASSY MAIN and the HARNESS-ASSY
607 B-209
DUP2
Connection between the SOLENOID ASSY DUP and the HARNESS-ASSY
611 D-204
DUP1
Connection between the MOTOR ASSY DUP INV and the HARNESS-ASSY
612 G-206
DUP1
500 FEEDER
P/J Coordinates Remarks
Connection between the SENSOR NO PAPER and the HARNESS ASSY
119 E-307
FEED3
Connection between the SENSOR T/R (P120) and the HARNESS ASSY
120 D-307
FEED3
Connection between the SWITCH FEEDER DOOR and the HARNESS-ASSY
121 C-308
FEED MAIN
435 E-309 Connection between the PWBA TRAY 500 and the HARNESS-ASSY FEED1
436 E-309 Connection between the PWBA TRAY 500 and the HARNESS-ASSY FEED2
Connection between the PWBA TRAY 500 and the HARNESS-ASSY FEED
437 E-309
MAIN
440 E-308 Connection between the PWBA MOT and the HARNESS-ASSY FEED MAIN
446 D-308 Connection between the PWBA MOT and the MOTOR ASSY FEEDER
Connection between the HARNESS ASSY MAIN and the HARNESS-ASSY
608 D-307
FEED1
Connection between the CLUTCH ASSY FEED and the HARNESS-ASSY
609 C-309
FEED MAIN
Connection between the SOLENOID FEED and the HARNESS-ASSY FEED
610 C-308
MAIN
Connection between the HARNESS ASSY FEED MAIN and the HARNESS-ASSY
618 D-307
FEED3
4358 D-309 Does Not Connect
7-4
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
101
102
109 108 117 114 614 T4 (IBT)
103
104
107
105
T2
220 (2BTR)
106
512
(1BTR)
107
513
(IBT)
108
514
105 (BCR)
109 510
(DEVE)
204
110 106
429
111
112
113
433 432 430 507 506 516 505 104 116
114
115
Leg_Sec04_001FA
7-5
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
116
117
100
118
119
120
121
203
122
102
123 101
124 202
125
126
127
128
103 605 603 604
129
130
Leg_Sec04_002FA
7-6
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
131
132
134
135
136
621
137
602
138
601
139
140
141
142
143
617 607
144
145
Leg_Sec04_003EB
7-7
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
146
417 418 422 414 416
147 415
404 412
403 421
148 405 420
409 411
406 413
149
151 500
201
502
152 501
515
153
600
504
154
128
503
155
156
CN29 508
509
157
CN70 608
158 CN71
159 CN72 1 2 3
160
Leg_Sec04_004FA
7-8
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
201
202
611 124 612
203
204
205
206
122
607
207
444
208
209 443
210
211
212
213
123 442
214
215
Leg_Sec04_005EA
7-9
Chapter 7 Wiring Data
7.2 P/J Layout
A B C D E F G H I J K L
301
302
303
304
121 608 618 120 119 446 440
305
306
307
308
309
310
311
313
314
315
Leg_Sec04_006EA
7-10
Chapter 7 Wiring Data
7.2 P/J Layout
Blank Page
7-11
Chapter 7 Wiring Data
7.3 Connection Chart
Symbol Description
Shows the connection to a part from a harness, wire, etc.
Shows a joining terminal with a leaf spring, etc. on a circuit board and the
corresponding connector (port) number.
Shows a connector that is directly mounted onto a circuit board and the
corresponding connector number.
7-12
Chapter 7 Wiring Data
7.3 Connection Chart
6 PWBA HVPS
SWITCH-INLK SWITCH PL12.1.9
FUSER P/J114 P/J403 P/J116 ASSY TOP P/J116 P/J515 P/J516
PL1.1.34 PL1.1.7
P/J504 P/J507
5 SWITCH-INLK
P/J201 P/J117 FUSER P/J117 P/J509 P/J505
MOT ASSY P/R PL1.1.34
PL11.1.6
P/J200 P/J401 P/J500 P/J508 P/J506
P/J503
9-2
P/J411 PWBA FUSER
DRIVE ASSY PRO CONT
HOUSING ASSY-DEVE PL9.2.5
PL11.1.2 PL12.2.12
IBT ASSY PL7.1.1
P/J414 2ND BTR ASSY PL6.1.12
P/J1 P/J2 FUSER ASSY
PL10.1.1
P/J3 P/J614
P/J4
2
MOTOR-PH
PWB ASSY ROT P/J409 P/J604
PL5.2.20
PL12.1.10
MOT ASSY ROT
P/J204 P/J433 P/J430 SOLENOID PICK UP
PL11.1.5 P/J605
PL4.1.23
P/J432
CLUTCH ASSY PRE REGI
P/J408 P/J603 P/J202
PL5.2.22
8
SENSOR FUSER IN CLUTCH ASSY REGI
P/J111 P/J620 P/J418 P/J203
PL6.1.3 PL5.2.2
PWBA
SENSOR 2BTR SWITCH-PH DOOR DUP-L
P/J100 PL13.4.13
RETRACT P/J112 PL5.2.23
PL6.1.22 SWITCH-DUP DOOR
P/J444 P/J122
PL13.3.7
P/J101 SENSOR OHP
SWITCH 2BTR PL5.2.16
COVER P/J113 P/J621 SOLENOID ASSY DUP
PL6.1.18 P/J611
PL13.2.7
SENSOR REGI
P/J102
SENSOR ASSY ADC PL5.2.19
P/J431 P/J422 SENSOR UPPER PASS
PL6.1.20 P/J124
PL13.2.10
SENSOR PAPER EMPTY
P/J103
MOT ASSY MICRO PL4.1.24
P/J600 MOTOR ASSY DUP INV
PL11.1.7 P/J612
PL13.2.18
P/J420 P/J607 P/J443
11 SENSOR LOW PASS MOTOR ASSY DUP
P/J123 P/J442
PL13.3.11 PL13.4.14
Leg_007_001FA
7-13
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
Symbols Description
Shows a plug.
Shows a jack.
P/JXX
YY
Shows Pin yy and Jack yy of connectors Pxx and Jxx.
Control
Shows a Control within the PWB section and an overview of it.
7-14
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
Symbols Description
+5VDC
Shows DC voltage.
+3.3VDC
7-15
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
1 DC POWER SUPPLY
Connection between the PWBA MCU and the LV/HVPS
Connection between the LV/HVPS and the PWBA FUSER CONTROL
Connection between the LV/HVPS and the MOT ASSY P/R
Connection between the LV/HVPS and the PWB ASSY ROT
Connection between the LV/HVPS and the SWITCH ASSY TOP
Connection between the SWITCH ASSY TOP and the SWITCH-INLK FUSER
Connection between the SWITCH-INLK FUSER and the LV/HVPS
3 FEEDER (500)
Connection between the PWBA MCU and the PWBA TRAY 500
Connection between the PWBA TRAY 500 and the CLUTCH ASSY FEED
Connection between the PWBA TRAY 500 and the SWITCH FEEDER
Connection between the PWBA TRAY 500 and the SENSOR NO PAPER
Connection between the PWBA TRAY 500 and the SENSOR T/R
Connection between the PWBA TRAY 500 and the SOLENOID FEEDER
Connection between the PWBA TRAY 500 and the PWBA MOT
Connection between the PWBA MOT and the MOTOR ASSY FEEDER
4 ROS
Connection between the PWBA MCU and the ROS ASSY
Connection between the ROS ASSY and the PWBA ESS
5 XEROGRAPHIC
Connection between the PWBA MCU and the DRIVE ASSY PRO
Connection between the PWBA MCU and the SENSOR TNER FULL
Connection between the PWBA MCU and the SENSOR IBT RETRACT
Connection between the PWBA MCU and the SENSOR TR-O
Connection between the PWBA MCU and the ANTENNA ASSY
Connection between the PWBA MCU and the MOT ASSY P/R
Connection between the LV/HVPS and the MOT ASSY P/R
6 HIGH VOLTAGE
Connection between the LV/HVPS and the PWBA HVPS
Connection between the LV/HVPS and the HOUSING ASSY-DEVE, IBT ASSY, 2ND BTR
ASSY
Connection between the LV/HVPS and the PWBA MCU
7-16
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
7 DEVELOPER
Connection between the PWBA MCU and the SENSOR HUM & TEMP
Connection between the PWBA MCU and the PWBA CRUM
Connection between the PWBA MCU and the MOT ASSY MAG
Connection between the PWBA MCU and the SENSOR ROTARY HOME POSI
Connection between the PWBA MCU and the ANTENNA CTRG
Connection between the PWBA MCU and the PWB ASSY ROT
Connection between the PWB ASSY ROT and the MOT ASSY ROT
Connection between the PWB ASSY ROT and the LV/HVPS
8 2nd BTR
Connection between the PWBA MCU and the SENSOR FUSER IN
Connection between the PWBA MCU and the SENSOR 2BTR RETRACT
Connection between the PWBA MCU and the SWITCH 2BTR COVER
Connection between the PWBA MCU and the SENSOR ASSY ADC
Connection between the PWBA MCU and the MOT ASSY MICRO
9 FUSER
Connection between the PWBA MCU and the MOT ASSY FUSER
Connection between the PWBA MCU and the FUSER ASSY
Connection between the PWBA MCU and the SWITCH-FUSER DOOR
Connection between the PWBA MCU and the FUSER LOCK SWITCH
Connection between the LV/HVPS and the PWBA FUSER CONTROL
Connection between the PWBA FUSER CONT and the FUSER ASSY
Connection between the PWBA FUSER CONT and the PWBA MCU
Connection between the PWBA FUSER CONT and the FUSER LOCK SWITCH
Connection between the LV/HVPS and the PWBA MCU
10 CONTROLLER
Connection between the PWBA MCU and the PWBA ESS
Connection between the PWBA ESS and the OP PANEL
Connection between the PWBA ESS and the LV/HVPS
11 DUPLEX
Connection between the PWBA MCU and the PWBA DUP-L
Connection between the PWBA DUP-L and the SENSOR LOW PASS
Connection between the PWBA DUP-L and the SWITCH-DUP DOOR
Connection between the PWBA DUP-L and the SOLENOID ASSY DUP
Connection between the PWBA DUP-L and the SENSOR UPPER PASS
Connection between the PWBA DUP-L and the MOTOR ASSY DUP INV
Connection between the PWBA DUP-L and the MOTOR ASSY DUP
7-17
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
1 DC POWER SUPPLY
SWITCH
ASSY
TOP
P/J502 P/J116 PL.1.1.7 P/J116
+5VDC
13 13 13
SWITCH-
INLK
FUSER
P/J117 PL.1.1.34 P/J117
I/L +5VDC
15 31 31
+5VDC
PWBA MCU
+5VDC PL12.2.1
P/J500 P/J401 Interlock
Supply I/L +5VDC
5 18 +5VDC
P/J502 P/J410 +5VDC
+5VDC
3 3
SG
4 4
+24VDC INTERLOCK
+24VDC +24VDC
Supply I/L +24VDC
5 5
I/L +24VDC
6 6
SG
7 7
SG
8 8
+3.3VDC
+3.3VDC +3.3VDC
Supply +3.3VDC
1 1
SG
2 2
PWB ASSY
ROT
PL12.1.10
P/J432
I/L +24VDC Interlock
11 1 +24VDC
SG
12 3
PWBA FUSER CONTROL
PL12.2.12
P/J503 P/J2
3 3
1 1
Leg_007_002FA
7-18
Chapter 7 Wiring Data
7.4 Connection Charts Between Parts
- Overcurrent Protection
All output will be suspended if each output (+24VDC, +5VDC, +3.3VDC) of the LV/HVPS is
short circuited between the earth or the ground.
The power supply of equipment is turned OFF after the short circuit is released. After some
time, the power is turned ON and each output resumes.
When the current exceeds 16A for each output, overcurrent protection will be activated.
- Overvoltage Protection
All output will be suspended if overvoltage occurs for each output of the LV/HVPS.
The voltage for each output when overvoltage protection is activated is as follows.
+24VDC:36VDC
+5VDC:7VDC
+3.3VDC:5VDC
- Power Save
7-19