ALMANSOORI INSPECTION SERVICES

LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT


This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010029330-JB-001 Date of Report: 07-Sep-2020


Job Allocation No: 5010029330 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-52 MUD PUMP 3
Due Date of Next Date of Last Proof Load Due Date of Date of Last
Date of Inspection
Inspection Test Next Proof Load Test Inspection
07-Sep-2020 06-Mar-2021 22-Apr-2018 N/A 10-Jan-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

500 kg N/A

01917783-3 Jib Crane 1 Manufacture Year of


Name Manufacturing
Drillmec 22-Apr-2018
Applicable Reference Standards : BS 2853 / SWIM
Applicable Reference Regulations: SWIM
Colour Code: Orange till the end of March, then Blue
NDT Details (if Any): MPI Acceptable (5010029330-JB/MPI-001)
Test Equipment Details: ACY-0097
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010029330-JB-002 Date of Report: 07-Sep-2020


Job Allocation No: 5010029330 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-52 MUD PUMP 2
Due Date of Next Date of Last Proof Load Due Date of Date of Last
Date of Inspection
Inspection Test Next Proof Load Test Inspection
07-Sep-2020 06-Mar-2021 22-Apr-2018 N/A 10-Jan-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

500 kg N/A

01917783-2 Jib Crane 1 Manufacture Year of


Name Manufacturing
Drillmec 22-Apr-2018
Applicable Reference Standards : BS 2853 / SWIM
Applicable Reference Regulations: SWIM
Colour Code: Orange till the end of March, then Blue
NDT Details (if Any): MPI Acceptable (5010029330-JB/MPI-002)
Test Equipment Details: ACY-0097
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010029330-JB-003 Date of Report: 07-Sep-2020


Job Allocation No: 5010029330 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-52 MUD PUMP 1
Due Date of Next Date of Last Proof Load Due Date of Date of Last
Date of Inspection
Inspection Test Next Proof Load Test Inspection
07-Sep-2020 06-Mar-2021 22-Apr-2018 N/A 10-Jan-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

500 kg N/A

01917783-1 Jib Crane 1 Manufacture Year of


Name Manufacturing
Drillmec 22-Apr-2018
Applicable Reference Standards : BS 2853 / SWIM
Applicable Reference Regulations: SWIM
Colour Code: Orange till the end of March, then Blue
NDT Details (if Any): MPI Acceptable (5010029330-JB/MPI-003)
Test Equipment Details: ACY-0097
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010029330-OB-001 Date of Report: 07-Sep-2020


Job Allocation No: 5010029330 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-52 Store
Due Date of Next Date of Last Proof Load Due Date of Date of Last
Date of Inspection
Inspection Test Next Proof Load Test Inspection
07-Sep-2020 06-Mar-2021 30-Dec-2018 N/A 10-Jan-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

2t N/A

124T20P016-006 Store beam 1 Manufacture Year of


Name Manufacturing
Drillmec 30-Dec-2018
Applicable Reference Standards : BS 2853 / SWIM
Applicable Reference Regulations: SWIM
Colour Code: Orange till the end of March, then Blue
NDT Details (if Any): MPI Acceptable (5010029330-OB/MPI-001)
Test Equipment Details: ACY-0097
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018
ALMANSOORI INSPECTION SERVICES
LIFTING EQUIPMENT THOROUGH EXAMINATION REPORT
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Report Number: 5010029330-OB-002 Date of Report: 07-Sep-2020


Job Allocation No: 5010029330 Type of Inspection: Visual & MPI
Name and Address of Owner Place of Inspection Sub location
Arabian Drilling Co. AD-52 Workshop
Due Date of Next Date of Last Proof Load Due Date of Date of Last
Date of Inspection
Inspection Test Next Proof Load Test Inspection
07-Sep-2020 06-Mar-2021 30-Nov-2018 N/A 10-Jan-2020
Safe Working Proof Load
Owner ID Description of Lifting Equipment Qty. Load Applied
(Specify Units) (Specify Units)

2t N/A

146T20P029-27 Workshop beam 1 Manufacture Year of


Name Manufacturing
Drillmec 30-Nov-2018
Applicable Reference Standards : BS 2853 / SWIM
Applicable Reference Regulations: SWIM
Colour Code: Orange till the end of March, then Blue
NDT Details (if Any): MPI Acceptable (5010029330-OB/MPI-002)
Test Equipment Details: ACY-0097
Is this the first examination after installation or assembly at a new site or location? : Yes ☐ No ☒
If the answer to the above question is YES has the equipment been installed correctly? Yes☐ No☐ N/A ☒
Was the examination carried out Within an interval of 6 months? Yes☒ No☐
Was the examination carried out Within an interval of 12 months? Yes☐ No☒
Was the examination carried out In accordance with an examination scheme? Yes☒ No☐
Was the examination carried out After the occurrence of exceptional circumstances? Yes☐ No☒
Identification and description of defect ,if any of any part found to have a defect which is or
None
could become a danger to persons : (If none, state NONE)
Is the above an existing or imminent danger to persons? Note-This is a reportable defect Yes☐ No☒
Is the above a defect which is not yet but could become a danger to persons? Yes☐ No☒
(If YES State the day by) Date:
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination(If none state NONE) Visual & MPI
IS THIS EQUIPMENT SAFE TO USE? Yes☒ No☐
Remarks (if Any) :
Inspected By Stamp QA/QC Stamp
Name: Mohamed Yasir
Qualification: LEEA &NDT Level II

Signature:
Name and address of employer of persons making and authenticating this report:
AlMansoori Inspection Services ,P.O.Box: 109442 ,Abu Dhabi,UAE, Email:mis@almansoori.biz, Web: www.almansoori.biz

This certificate is granted subject to the condition that is understood and agreed that nothing herein contained shall be deemed to relieve any designer, manufacturer,
seller, repairer or operator of any warranty, expressed or implied and AlMansoori liability shall be limited to the wilful negligence or deliberate omissions of its
employees. Under no circumstances whatsoever, shall AlMansoori be liable for any injury or damage to any person occurring by reason of negligent operation or
any defect in materials, machinery, equipment or other items other than those defects ascertainable by normally accepted testing standards and only those items
actually inspected by AlMansoori and which are covered by this certificate.
F. 836
Rev. 03
28.11.2018

You might also like