Professional Documents
Culture Documents
Troubleshooting:
Controller:
ENG
Action Level:
L01
Category of History:
Electrical system
Details of Failure:
Low voltage appears in signal circuit of crankcase pressure sensor.
Action of Controller:
Takes it that crankcase pressure is at fixed value (0 kg/cm² {0 psi}) and allows engine to run.
Problem on Machine:
N/A
Related Information:
1) Signal voltage from crankcase pressure sensor can be checked with monitoring function.
(Code: 48401 (V))
2) Pressure from crankcase pressure sensor can be checked with monitoring function. (Code:
48400 (MPa))
3) Method of reproducing failure code: Turn starting switch to ON position.
Possible Causes:
1) Defective wiring harness connector
2) Defective sensor power supply system
3) Defective sensor power supply system
4) Open circuit in wiring harness (wire breakage or defective contact of connector)
5) Ground fault in wiring harness (contact with GND circuit)
6) Short circuit in wiring harness
7) Defective crankcase pressure sensor (internal defect)
8) Defective engine controller
Page 1