Tensile Test report

Customer : Komar Pre-load : 0,3 MPa


Test standard : DIN EN ISO 527-1 Speed, tensile modulus : 1 mm/min
Material : HDPE + Bonggol Jagung 10% Test speed : 200 mm/min
Machine data : Zwick Z020 Grip to grip separation at the start position : 115,00 mm
Gage length, standard travel : 50 mm

Test results:
Force Et m m b b b h Travel Gage length, standard travel
Legend No. N MPa MPa % MPa % mm mm mm mm
1 551,08 307 14,3 31 14,3 31 10,08 3,82 82,31 50
2 556,01 292 14,5 30 14,5 30 10,05 3,82 102,51
3 553,35 318 14,6 30 14,6 30 9,97 3,81 65,56

Series graph:
20

15
Stress in MPa

10

0
0 50 100 150 200
Strain in %

Statistics:
Series Travel µ Force Et m m b b b h
n=3 mm N MPa MPa % MPa % mm mm
x 83,46 - 553,48 306 14,5 30 14,5 30 10,03 3,817
s 18,51 - 2,47 13,1 0,130 0,50 0,130 0,50 0,05686 0,005774
 [%] 22,17 - 0,45 4,28 0,90 1,65 0,90 1,65 0,57 0,15

3 Tensile HDPE + Bonggol Jagung 10%.zs2 Page 1/1